Model | UV1500CS |
Wavelength Range | 190~1100nm |
Wavelength | automatic adjustment |
Optical circuit structure | C-T type Parallel double beam |
Band Width | 2nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤0.2nm |
Photometric Accuracy | ±0.3% τ |
Photometric Repeatability | 0.15% τ |
Stray Light | ≤0.04% τ (220nm NaI,340nm NaNO2) |
Stability | 0.001A/h@500nm |
Photometric Mode | T,A,C,E |
Wavelength Setting | Automatic |
Photometric Display Range | -0.3~3A |
Display Mode | Touch LCD Screen (7 inches). |
Detector | Import Silicon Photodiode |
Light Source | Import Deuterium Lamp & Tungsten Halogen Lamp |
Power Requirement | AC 220V/50Hz 110V/60Hz |
Power | 120W |
Dimensions(W*D*H) | 120W 480×350×220mm |
Brand Name | Macylab |
Model Number | UV-1500CS |
Certification | CE,FCC,FDA,ROHS,9001 |
Place of Origin | China |
View Detail Information
Explore similar products
Automatic Adjustment Wavelength Ultraviolet Visible Spectrophotometer Single
TOC Ultraviolet Visible Spectrophotometer 120W Water temperature
Macylab Uv Visible Spectrometer Single Beam Laboratory Equipment
Monochloramine TOC UV Visible Spectrophotometer / UV-Vis Spectrometry
Product Specification
Payment Terms | L/C, T/T, Western Union, MoneyGram, D/P, D/A | Supply Ability | 5000set/M |
Delivery Time | 5-7days | Packaging Details | Waterproof paper then Carton |
Model | UV1500CS | Wavelength Range | 190~1100nm |
Wavelength | automatic adjustment | Optical circuit structure | C-T type Parallel double beam |
Band Width | 2nm | Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤0.2nm | Photometric Accuracy | ±0.3% τ |
Photometric Repeatability | 0.15% τ | Stray Light | ≤0.04% τ (220nm NaI,340nm NaNO2) |
Stability | 0.001A/h@500nm | Photometric Mode | T,A,C,E |
Wavelength Setting | Automatic | Photometric Display Range | -0.3~3A |
Display Mode | Touch LCD Screen (7 inches). | Detector | Import Silicon Photodiode |
Light Source | Import Deuterium Lamp & Tungsten Halogen Lamp | Power Requirement | AC 220V/50Hz 110V/60Hz |
Power | 120W | Dimensions(W*D*H) | 120W 480×350×220mm |
Brand Name | Macylab | Model Number | UV-1500CS |
Certification | CE,FCC,FDA,ROHS,9001 | Place of Origin | China |
High Light | uv-1500pc ultraviolet visible spectrophotometer ,usb ultraviolet visible spectrophotometer ,lcd dual beam uv vis spectrophotometer |
● ingle-chip microcomputer control, Touch LCD Screen (7 inches)
● Large LCD display can display multiple sets of data
● Huge memory space to store multiple sets of data and curves
● Auto zero,100% adjustment function
● Wavelength automatic adjustment
● Wrap lights, automatic filter change , large sample pool (5mm ~ 100mm)
● Standard samples having a maximum ten-point standard curve measurement functions built
● Direct input by K, B factor for quantitative measurement standard curve
● Can be directly input and the corresponding standard concentration values establish a standard curve for quantitative measurement
● Adjustable electric saving standard curve parameter measuring set, can save a plurality of standard curve
● Can be edited at any time of the standard curve , user-friendly
● General Parallel printer interface with or slightly beat interfaces can print the title bar, the measurement data , curve parameters , the standard curve and the curve sample points
● With USB interface
● PC control can be achieved through more accurate and flexible measurement requirements ( standard )
Software features
● Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan
● Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance
● Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was
● Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test
● DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein
Technical Specifications
Model | UV1500CS |
Wavelength Range | 190~1100nm |
Optical circuit structure | C-T type Parallel double beam |
Band Width | 2nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤0.2nm |
Photometric Accuracy | ±0.3% τ |
Photometric Repeatability | 0.15% τ |
Stray Light | ≤0.04% τ (220nm NaI,340nm NaNO2) |
Stability | 0.001A/h@500nm |
Photometric Mode | T,A,C,E |
Wavelength Setting | Automatic |
Photometric Display Range | -0.3~3A |
Display Mode | Touch LCD Screen (7 inches). |
Detector | Import Silicon Photodiode |
Light Source | Import Deuterium Lamp & Tungsten Halogen Lamp |
Power Requirement | AC 220V/50Hz 110V/60Hz |
Power | 120W |
Dimensions(W*D*H) | 480×350×220mm |
Weight | 15Kg |
Company Details
Business Type:
Manufacturer
Year Established:
2010
Total Annual:
3000000-5000000
Employee Number:
20~50
Ecer Certification:
Active Member
Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in... Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in...
Get in touch with us
Leave a Message, we will call you back quickly!