China C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole
China C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole

  1. China C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole
  2. China C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole
  3. China C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole

C-T Parallel double beam and touch screen 190-1100nm wavelength range ultraviole

  1. MOQ: 1pcs
  2. Price: USD890-1300
  3. Get Latest Price
Payment Terms L/C, T/T, Western Union, MoneyGram, D/P, D/A
Supply Ability 5000set/M
Delivery Time 5-7days
Packaging Details Waterproof paper then Carton
Model UV1500CS
Wavelength Range 190~1100nm
Wavelength automatic adjustment
Optical circuit structure C-T type Parallel double beam
Band Width 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Photometric Accuracy ±0.3% τ
Photometric Repeatability 0.15% τ
Stray Light ≤0.04% τ (220nm NaI,340nm NaNO2)
Stability 0.001A/h@500nm
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -0.3~3A
Display Mode Touch LCD Screen (7 inches).
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 120W 480×350×220mm
Brand Name Macylab
Model Number UV-1500CS
Certification CE,FCC,FDA,ROHS,9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T, Western Union, MoneyGram, D/P, D/A Supply Ability 5000set/M
Delivery Time 5-7days Packaging Details Waterproof paper then Carton
Model UV1500CS Wavelength Range 190~1100nm
Wavelength automatic adjustment Optical circuit structure C-T type Parallel double beam
Band Width 2nm Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm Photometric Accuracy ±0.3% τ
Photometric Repeatability 0.15% τ Stray Light ≤0.04% τ (220nm NaI,340nm NaNO2)
Stability 0.001A/h@500nm Photometric Mode T,A,C,E
Wavelength Setting Automatic Photometric Display Range -0.3~3A
Display Mode Touch LCD Screen (7 inches). Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W Dimensions(W*D*H) 120W 480×350×220mm
Brand Name Macylab Model Number UV-1500CS
Certification CE,FCC,FDA,ROHS,9001 Place of Origin China
High Light uv-1500pc ultraviolet visible spectrophotometerusb ultraviolet visible spectrophotometerlcd dual beam uv vis spectrophotometer

● ingle-chip microcomputer control, Touch LCD Screen (7 inches)

● Large LCD display can display multiple sets of data

● Huge memory space to store multiple sets of data and curves

● Auto zero,100% adjustment function

● Wavelength automatic adjustment

● Wrap lights, automatic filter change , large sample pool (5mm ~ 100mm)

● Standard samples having a maximum ten-point standard curve measurement functions built

● Direct input by K, B factor for quantitative measurement standard curve

● Can be directly input and the corresponding standard concentration values establish a standard curve for quantitative measurement

● Adjustable electric saving standard curve parameter measuring set, can save a plurality of standard curve

● Can be edited at any time of the standard curve , user-friendly

● General Parallel printer interface with or slightly beat interfaces can print the title bar, the measurement data , curve parameters , the standard curve and the curve sample points

● With USB interface

● PC control can be achieved through more accurate and flexible measurement requirements ( standard )

 

Software features

● Wavelength Scan: the measured object can be 190nm-1100nm full band spectrum scan , can also be segmented scan

● Kinetic tests: the time of the measured object scanning , timely detection of changes in concentration caused by changes in absorbance

● Quantitative measurement: by establishing a standard curve , the concentration can be measured in the analysis was

● Multi- wavelength testing : set a plurality of wavelengths simultaneously , the measured absorbance of a plurality of wavelengths in the test

● DNA / protein test: the test formula purity of nucleic acid and protein concentration analysis of DNA / protein

 

Technical Specifications

Model UV1500CS
Wavelength Range 190~1100nm
Optical circuit structure C-T type Parallel double beam
Band Width 2nm
Wavelength Accuracy ±0.5nm
Wavelength Repeatability ≤0.2nm
Photometric Accuracy ±0.3% τ
Photometric Repeatability 0.15% τ
Stray Light ≤0.04% τ (220nm NaI,340nm NaNO2)
Stability 0.001A/h@500nm
Photometric Mode T,A,C,E
Wavelength Setting Automatic
Photometric Display Range -0.3~3A
Display Mode Touch LCD Screen (7 inches).
Detector Import Silicon Photodiode
Light Source Import Deuterium Lamp & Tungsten Halogen Lamp
Power Requirement AC 220V/50Hz 110V/60Hz
Power 120W
Dimensions(W*D*H) 480×350×220mm
Weight

15Kg

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2010

  • Total Annual:

    3000000-5000000

  • Employee Number:

    20~50

  • Ecer Certification:

    Active Member

    Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in...     Macylab Instruments Inc.is a high-tech enterprise with independent intellectual property rights . Macy hold the pioneering concept "technology - because you change " , and as a business purpose, and constantly explore, bold innovation. Especially in the field of analytical in...

+ Read More

Get in touch with us

  • Reach Us
  • Macylab Instruments Inc.
  • A-711, Haige International Building, Xuanwumen, Xicheng District, Beijing China
  • http://www.laboratoryspectrophotometer.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement