Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"Environment Power Distribution Monitoring System iFSU centralized control","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1e\/26\/02039e5b604acb5ec1bbeb5d9a38-200x200-1\/environment_power_distribution_monitoring_system_ifsu_centralized_control.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Payment Terms":"L\/C, T\/T"}}
{"title":"LoRAWAN Environmental Power Distribution Monitoring System Platform Intelligent","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/87\/e6\/a5149e6a88654e5add1a3de0058d-200x200-1\/lorawan_environmental_power_distribution_monitoring_system_platform_intelligent.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
{"title":"ISO\/IEC 9001 ISO\/IEC 27001 Power Distribution Monitoring System Management","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/de\/1c\/9e9823ceb018d5889dc7bd51bf57-200x200-1\/iso_2fiec_9001_iso_2fiec_27001_power_distribution_monitoring_system_management_timewave.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
{"title":"Outdoor Indoor PDU Monitoring Software Controlling Management System","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/69\/9a\/4bdc6cb2b17ae63d54bf7f79f918-200x200-1\/outdoor_indoor_pdu_monitoring_software_controlling_management_system.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
{"title":"Energy Management Power Distribution Monitoring System IoT Intelligent","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/79\/5d\/a59396f0fd5631300c5fbed4116c-200x200-1\/energy_management_power_distribution_monitoring_system_iot_intelligent.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
{"title":"LoRAWAN Environmental Power Distribution Monitoring System Platform Intelligent","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/87\/e6\/a5149e6a88654e5add1a3de0058d-200x200-1\/lorawan_environmental_power_distribution_monitoring_system_platform_intelligent.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
{"title":"ISO\/IEC 9001 ISO\/IEC 27001 Power Distribution Monitoring System Management","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/de\/1c\/9e9823ceb018d5889dc7bd51bf57-200x200-1\/iso_2fiec_9001_iso_2fiec_27001_power_distribution_monitoring_system_management_timewave.jpg","attrs":{"Brand Name":"TimeWave","Certification":"ISO\/IEC 20000-1,ISO\/IEC 27001,ISO\/IEC 9001","Place of Origin":"Hubei , China","Minimum Order Quantity":"Negotiable"}}
power distribution room environment monitoring system Distribution equipment management
Platform Introduction
According to the actual situation of the power distribution room, we independently developed the TimeWaveCloud distribution room power environment monitoring platform and intelligent energy consumption dynamic environment monitoring unit (iFSU). It realizes load operation monitoring such as current, voltage, power and power factors, bus temperature measurement monitoring, cable temperature measurement monitoring, environmental monitoring, entrance guard, air conditioner/fan control, etc. Realize power environment monitoring to avoid power distribution equipment operation failure caused by out of control operation environment. Extend the service life of equipment and ensure the safety of maintenance personnel.
Introduction to system functions and features
Centralized control: iFSU centralized control;
Communication mode: uplink 4G (CAT1)/WLAN, downlink RS485/wireless;
System integration: power monitoring, environmental monitoring, security monitoring, bus/cable temperature monitoring are integrated;
Real time monitoring: monitoring and displaying the voltage, current, active power, reactive power, power factor and other operating parameters of the equipment in the power distribution room. And monitoring the environmental operation parameters of the power distribution room;
Real time alarm: alarm for abnormal electrical parameters, temperature, humidity, equipment failure or communication failure;
Data query: display and query the real-time operation information of the power distribution room;
Display mode: Kanban display, chart and curve graph display;
Operation report: daily, monthly, annual and operation report;
Permission management: define the permissions of users at different levels to ensure reliable and safe operation;
Layout: cloud platform, local layout;
Wiring diagram
Primary wiring diagram of 10kV box type substation/distribution room
Related hardware products
Functions of system software
Monitoring data information:Electric energy data: various electric energy parameters, voltage, current, active power, reactive power, power factor, etc;
Out of limit data: voltage, power, temperature, etc;
Temperature and humidity data: bus contact temperature, cable temperature, ambient temperature and ambient humidity;
Smog alarm status and alarm elimination;
Screen display
Platform access overview (platform operation and maintenance): mainly showing the total access, total transformer quantity, total transformer capacity, total equipment quantity and daily load, daily electricity quantity and map display. The platform operation and maintenance display can be shared.
More features
User presentation overview: it displays the power consumption profile, site profile, operation status, curve and alarm of all users. Users can be selected from the drop-down box;
Power parameters: display real-time and historical voltage, current, power, power factor and other curve information of the specified site;
Temperature information: it displays the curve of the ambient temperature in the substation room, the collection time, the average value and other information;
The system provides the pre alarm configuration function, which can realize the configuration and management of equipment alarm (equipment offline, analog quantity out of limit, temperature out of limit, etc.) strategies. You can set the trigger time of the alarm, the type of the alarm, whether to enable SMS, audible and visual alarm, etc.
Pre alert Info: The alert information of the site is recorded here. Alarm includes: voltage, current and other line crossing alarm; Switching value alarm; Event alarm; Other alarms. It can record the total number and category of alarms, and filter alarm information according to different search conditions. You can also view the alarm status and send orders to the operation and maintenance personnel to deal with problems through the dispatch function of the alarm.
User management: 4 sub items, including user permission setting, operation record, control record and system record. User permissions can be set and changed under high-level user authorization. Operation records are records of system operations, such as page switching, system data query, and equipment operations. The control record is used to record the control information issued by the system, including time, user and controls operated. It serves as an important basis for subsequent control system analysis. The system records the relevant status of the system operation.
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Exporter,Seller
Year Established:
2017
Total Annual:
10000000-15000000
Employee Number:
80~100
Ecer Certification:
Verified Supplier
Wuhan Time Wave Network Technology Co., Ltd realizes the energy supervision service platform based on the LPWAN core technology.provide customers with one-stop overall solutions and metering terminal,system platform, project construction and system maintenance.
We developed the "Ti... Wuhan Time Wave Network Technology Co., Ltd realizes the energy supervision service platform based on the LPWAN core technology.provide customers with one-stop overall solutions and metering terminal,system platform, project construction and system maintenance.