Payment Terms | T/T |
Supply Ability | 30~50 sets / Month |
Delivery Time | 30 days |
Packaging Details | Export standard paper carton or wooden case |
Product name | Dry cooler |
Installation | Floor standing |
Heat capacity | 104KW |
Warranty | 1 year |
Air flow | 42000m³/h |
Brand name | Longer leader |
Video | Provided |
After-sales Service Provided | Online support |
Type | dry cooling tower |
Brand Name | Longer Leader |
Model Number | LDDC-0103V-3R-AC710 |
Certification | ISO9001, CQC |
Place of Origin | China |
View Detail Information
Explore similar products
Custom Design Copper Tube Dry Cooler For Genset Engine Cooling Air Cooler
Efficient Heat Dissipation Vertical Dry Cooler HVAC With Fan Custom Design For
25-2000kw V Shaped Industrial Process Dry Cooler System Free Cooling Refrigerati
Heat Dissipation Dry Cooler With High Efficiency EC Fan For Machinery Factory
Product Specification
Payment Terms | T/T | Supply Ability | 30~50 sets / Month |
Delivery Time | 30 days | Packaging Details | Export standard paper carton or wooden case |
Product name | Dry cooler | Installation | Floor standing |
Heat capacity | 104KW | Warranty | 1 year |
Air flow | 42000m³/h | Brand name | Longer leader |
Video | Provided | After-sales Service Provided | Online support |
Type | dry cooling tower | Brand Name | Longer Leader |
Model Number | LDDC-0103V-3R-AC710 | Certification | ISO9001, CQC |
Place of Origin | China | ||
High Light | vertical dry chiller ,vertical dry air chiller ,save water dry chiller |
Save Water Vertical Dry Coolers Suitable For Water-Scarce Areas
Model | Air flow(m3/h) | Heat capacity(kw) | Water flow(l/s) | Fan size(mm) | Fan unit(pcs) | Motor power(kw) | Unit size(mm):L*W*H |
LDDC-0101P-3R-AC630 | 8300 | 24.87 | 1.21 | 630 | 1 | 0.74 | 1000*980*880 |
LDDC-0101P-4R-AC630 | 8800 | 29.26 | 1.44 | 630 | 1 | 0.74 | 1000*980*900 |
LDDC-0101P-3R-AC710 | 11000 | 32.47 | 1.57 | 710 | 1 | 1.23 | 1150*1100*880 |
LDDC-0101P-4R-AC710 | 11500 | 38.02 | 1.86 | 710 | 1 | 1.23 | 1150*1100*900 |
LDDC-0102P-3R-AC630 | 16600 | 50.36 | 2.43 | 630 | 2 | 1.48 | 1950*980*880 |
LDDC-0102P-4R-AC630 | 17600 | 58.53 | 2.86 | 630 | 2 | 1.48 | 1950*980*900 |
LDDC-0102P-3R-AC710 | 22000 | 66.94 | 3.23 | 710 | 2 | 2.46 | 2250*1100*880 |
LDDC-0102P-4R-AC710 | 23000 | 76.24 | 3.71 | 710 | 2 | 2.46 | 2250*1100*900 |
LDDC-0103P-3R-AC630 | 24900 | 75.65 | 3.66 | 630 | 3 | 2.22 | 2900*980*880 |
LDDC-0103P-4R-AC630 | 26400 | 86.33 | 4.2 | 630 | 3 | 2.22 | 2900*980*900 |
LDDC-0103P-3R-AC710 | 33000 | 99.86 | 4.82 | 710 | 3 | 3.69 | 3350*1100*880 |
LDDC-0103P-3R-AC710 | 34500 | 114.11 | 5.54 | 710 | 3 | 3.69 | 3350*1100*900 |
LDDC-0104P-3R-AC630 | 33200 | 102.35 | 4.95 | 630 | 4 | 2.96 | 3850*980*888 |
LDDC-0104P-4R-AC630 | 35200 | 116.53 | 5.68 | 630 | 4 | 2.96 | 3850*980*900 |
LDDC-0104P-3R-AC710 | 44000 | 134.91 | 6.52 | 710 | 4 | 4.92 | 4450*1100*880 |
LDDC-0104P-4R-AC710 | 46000 | 153.86 | 7.48 | 710 | 4 | 4.92 | 4450*1100*900 |
A dry coolers is the same as air cooled condensing unit but utilizes some liquid solutions, such as water, ethylene glycol/water, to transfer hear being replace of refrigerant and compressor.
A dry cooler system are often see in Data centers where excess heat needs to be removed but low levels of humidity are not required.
A significant feature of dry cooler system is that no liquid evaporation takes place, which eliminates the need for make-up water.
As closed-circuit systems, dry coolers deliver several benefits compared to wet cooling towers, including lower initial costs and maintenance, improved system reliability and increased uptime.
Dry coolers can help to make a building working more efficiently. Though this system is not known for saving energy, it can be used as a condensing unit for a heat recovery chiller. When a heat recovery chiller supplements a chilled water system, there will be ask for a system to remove excess heat. This is the perfect application for a dry cooler, which serves as a condensing unit or cooling tower.
Why choose dry cooler replace of cooling tower?
No water consumption, eco-friendly - Dry Coolers do not require water. Instead, air is blown over a heat exchanger in order to remove the heat from the liquid in the system..
Easy maintainence - Dry Coolers are easier to maintain because the water is not exposed to air (closed loop) and they do not require water testing . Cooling Towers are susceptible to degradation through fouling (getting clogged up), scaling (water-deposit build-ups) corrosion (gradual breakdown due to the environment), and require testing for the prevention of Legionnaire’s disease.
Robust structure
Common dry cooler designs are flatbed units with either vertical or horizontal airflow direction or V-shaped units with one or two rows of axial fans with lateral air suction and discharge from the top.
Dry coolers are often used in applications where water is scarce or where the use of water is prohibited due to environmental regulations. They are also commonly used in industrial processes, such as power generation and chemical processing, where cooling is required to maintain optimal operating conditions.
Data center, office building, hospitals, industrial / process system, heat transfer / recuperation, power generation and induction cooling.
no water consumption, easy maintenance, eco-friendly.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2018
Total Annual:
8,000,000-12,000,000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Latest ventilation technology factory locates in Dongguan city of China with an area of nearly 3,000 square meter, assembling and manufacturing products of commercial to industrial air conditioning with capacity up to 400kw. Longer Leader is a trusted provider of custom a... Latest ventilation technology factory locates in Dongguan city of China with an area of nearly 3,000 square meter, assembling and manufacturing products of commercial to industrial air conditioning with capacity up to 400kw. Longer Leader is a trusted provider of custom a...