Payment Terms | L/C, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 1000 Pieces per Month |
Delivery Time | 8 - 12 work days |
Packaging Details | Export wooden box packaging |
Rotor Type | Anti-Corrosion Stainless steel |
Axial and radial casing protection | Stainless steel 316L |
Seal | Double-acting mechanical seal |
Flow | 246 m³/h |
Self-priming | Up to 9.5 m |
Medium | Chemicals |
Rate of flow | 1.125 l/rev |
Pump of material | 316L Stainless steel |
Brand Name | ACCUVON |
Model Number | AP80 |
Certification | API , IOS , CE, 3A , FDA |
Place of Origin | Guangdong , China |
View Detail Information
Explore similar products
API Antiwear Stainless Steel Lobe Pump For Paper Pulp Industry
Stainless Steel Rotary Positive Displacement Pump Tri Lobe With Double Seal
Practical SS304 Sanitary Lobe Pump , 600Rpm Sanitary Positive Displacement Pump
4-246m3/H Stainless Steel Lobe Pump Antiwear For Food Processing
Product Specification
Payment Terms | L/C, D/P, T/T, Western Union, MoneyGram | Supply Ability | 1000 Pieces per Month |
Delivery Time | 8 - 12 work days | Packaging Details | Export wooden box packaging |
Rotor Type | Anti-Corrosion Stainless steel | Axial and radial casing protection | Stainless steel 316L |
Seal | Double-acting mechanical seal | Flow | 246 m³/h |
Self-priming | Up to 9.5 m | Medium | Chemicals |
Rate of flow | 1.125 l/rev | Pump of material | 316L Stainless steel |
Brand Name | ACCUVON | Model Number | AP80 |
Certification | API , IOS , CE, 3A , FDA | Place of Origin | Guangdong , China |
High Light | Chemical Stainless Steel Lobe Pump ,Anti Corrosion Stainless Steel Lobe Pump ,316L Lobe Pump Chemical |
Professional Chemical Grade Anti-Corrosion Hot Durable Rotor Pump
Operating Principles:
When pump lobes rotates, the space between 2 lobes increase, it will create a partial vacuum to transfer fluid into pump chamber, The pump shaft keeps turning, lobes will continue to create space to delivery fluid, the tolerance between lobes and chamber ensure the space is suitable to filled. When the pump chamber is fully filled, the fluid will be transfer to outlet.
Specifications:
Description | Rotary Lobe Pumps |
Rotor | Plastic / tri-lobe with screw profile / PTFE |
Seal | Electric sealing sensor / Double-acting mechanical seal |
Axial and radial casing protection | Wear-resistant steel / Hardened steel / Stainless steel / SIC |
Drive | Variable geared motor / Combustion motor / Hydraulic motor |
Pump | Full of stainless steel |
Gear | Helical geared motor / Manual adjustable speed motor |
Speed | 10 - 600 rpm |
Custom printing | Acceptable |
Parameter of AP 80
Drive | Weight | Dimensions | |
KW | KG | L / mm | H / mm |
3 | 190 | 1158 | 394 |
4 | 202 | 1178 | 419 |
5.5 | 223 | 1258 | 454 |
7.5 | 236 | 1298 | 454 |
11 | 291 | 1380 | 509 |
15 | 354 | 1425 | 509 |
Design 1 | Short, s traight pipe connectors with connection flange and gasket, in mm / inches approx.
AP 80 | DN 50 mm | DN 65 mm | DN 80 mm | DN 100 mm | DN 125 mm |
Solution guidance
Problem | Possible Cause | Remedy |
| Direction of Rotation | Check direction of rotation is in line with arrow on casing and nameplate |
Air pocket in suction line | Ensure suction line filled with fluid, pipework slopes upwards, no kinks in suction line and pipework is as straight as possible. | |
Relief Valve Failure | Clean Relief Valve. Check pressure setting. Recalibrate | |
Check Valve Jammed | Clean check valve. Check operation | |
Air Ingress through Seal | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
| Relief Valve Opening or Jammed | Check relief valve settings. Recalibrate. Check and clean as a plug may have formed or solid entered jamming open. |
Air Ingress | Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary. | |
Low NPSH | Shorten and enlarge suction line diameter. Deepen suction pipe, increase tank contents, reduce pump speed and check fluid viscosity against pump design | |
Pump Worn | Check internal lobe spacing. Replace lobes | |
Check Valve Jammed | Clean check valve. Check operation | |
| Pump Cavitating | Increase pipework diameter. Reduce suction head. Check fluid viscosity. Clean filters. Reduce pump speed. Increase fluid level in tank. |
Lobe / Rotor Damage | Check lobes and replace if necessary | |
Misalignment | Realign Pump. Check coupling and rubber | |
Vibration in safety valve | Increase pressure setting or replace |
Structure features
The pump cavity design is so simple. All models of pumps retain simple design styles. The fast -opening pump cover is opened to provide guarantee for user maintenance personnel without disassembling the pipeline. The driver can guarantee online repair. Greatly reduced the stop time. Before and after, the upper and lower wear -resistant internal lining design, comprehensively ensure the non -wear of the pump shell and ensure long -term durability. Such a simple maintenance characteristics reduce the operating cost of the entire life cycle of the equipment.
Quality inspection photos
Company Details
Business Type:
Manufacturer
Year Established:
2008
Employee Number:
200~500
Ecer Certification:
Verified Supplier
Accuvon (Guangzhou) Pumps Co., Ltd. is a Sino-German joint venture established in 2008. It specializes in design, development, manufacturing, sales, engineering applications and technical services for rotor pumps. In accordance with the German DN industrial standards and technical requirements , lic... Accuvon (Guangzhou) Pumps Co., Ltd. is a Sino-German joint venture established in 2008. It specializes in design, development, manufacturing, sales, engineering applications and technical services for rotor pumps. In accordance with the German DN industrial standards and technical requirements , lic...
Get in touch with us
Leave a Message, we will call you back quickly!