Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 2000 SET |
Delivery Time | 7-15 DAYS |
Packaging Details | WOODEN CASE |
Rated voltage | 33kv 36kv 40.5kv |
Rated current | 400A-3150A |
Function | control and protection |
Installation Location | power plant |
Warranty | 24 months |
Medium | SF6 |
Operation type | electric or manual |
life span | 15 YEARS |
rated breaking current | 31.5kA |
Brand Name | XG |
Model Number | LW8A |
Certification | ISO |
Place of Origin | XIAN,CHINA |
View Detail Information
Explore similar products
LW8-40.5KV 35KV 36kv 40.5kv Outdoor SF6 Gas Circuit Breaker
33KV 36KV 40.5KV Outdoor 3 Phase 3 Poles SF6 Circuit Breaker
LW36-110KV 126KV 132KV 145KV Outdoor 3 Phase Circuit Breaker
LW36 Live Tank 145kv 1250A 2500A 3150A SF6 Gas Circuit Breaker
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 2000 SET |
Delivery Time | 7-15 DAYS | Packaging Details | WOODEN CASE |
Rated voltage | 33kv 36kv 40.5kv | Rated current | 400A-3150A |
Function | control and protection | Installation Location | power plant |
Warranty | 24 months | Medium | SF6 |
Operation type | electric or manual | life span | 15 YEARS |
rated breaking current | 31.5kA | Brand Name | XG |
Model Number | LW8A | Certification | ISO |
Place of Origin | XIAN,CHINA | ||
High Light | LW8A-40.5 Live Tank Circuit Breaker ,33kv Live Tank Circuit Breaker ,SF6 Live Tank Circuit Breaker |
1. LW8A-40.5 Type live tank 33kv 36kv SF6 Circuit Breaker
LW8A-40.5 Type live tank 33kv 36kv SF6 Circuit Breaker Is three-phases electrical system with alternating current 50HZ and the rated voltage 40.5kV.It is used for contolling and protecting the electrical system and measuring the current transformers.
2. Advantages
1.It conforms to GB1984 standard,GB/T28001-2011 idt OHSAS18001:2007,GB/T 24001-2004 idt ISO14001:200;
2.Frequent operation, each set can be installed with 12 current transformers;
3.The new sf6mkz pointer type densitometer, the pressure gauge reading is not affected by the temperature change.
3. Environmental Conditions
The daily average saturated vapor pressure: ≤2.2KPa;
The monthly average value: ≤1.8KPa.
Altitude: ≤3000m
Seismic intensity: ≤8
Air pollution level: Level Ⅲ
Ambient temperature: -30°C~+40°C
Relative humidity: ≤95%or≤90%
Wind pressure: ≤700pa
The installation shall be free from fire, explosion, severe vibration, chemical corrosion and serious pollution.
4. Technical Parameter
Name | Data | |
Rated voltage | 40.5 | |
Rated current(A) | 1600/2000 | |
Rated Insulate level | Power frequency withstand voltage(kV)1min | 95 |
Thunder impulse withstand vltage (kV) | 185 | |
Rated short-circuit breaking current(kA) | 25/31.5 | |
Rated outof-phase breaking current (kA) | 7.9/10 | |
breaking current of earth fault in different phase(kA) | 27.4/34.8 | |
Rated breaking current of single capacitor bank(A) | 400 | |
Rated Operating sequence | O-0.3S-CO-180S-CO | |
Rated SF6 gas pressure(Mpa) | 0.5 | |
Switch-off time(on rated voltage)(ms) | 30≤t≤40 | |
Switch-on time(on rated voltage)(ms) | 60≤t≤80 | |
Rated short-circuit making current(peak) (kA) | 63/80 | |
Rated short-circuit duration (s) | 4 | |
Rated short-circuit with stand current (kA) | 25/31.5 | |
Rated peak value withstand current(kA) | 63/80 | |
Mechanical life (time) | 10000 | |
Cumulative breaking times of rated short-circuit breaking current 31.5 kA/40kA(time) | 20 | |
Cumulative breaking times of rated current(time) | 2000 | |
Annual leakAge rate of SF6(%) | ≤0.5 | |
Water content of SF6(VV)(PPm) | ≤150 | |
Outer insulating leakAge ratio distance(mm/kV) | ≥25,≥31 | |
Weight of the circuit breaker(KG) | 1000 |
5. Photo
6. Factory
7. FAQ
1. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.
2. Usually shipped by sea, small order or urgent order we can send you by air.
3. All our activities are accredited to ISO 14001:2015 and IEC standard.
4. Technology ensure the quality satisfy international request.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1997
Total Annual:
200000000-450000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
XIGAO Electricenergy Group Co., Ltd is founded in 1993, 320000m2 plant, specialized in manufacturing high & low voltage power transmission and distribution (PTD) equipment, always focusing on the business at collection of research, design, OEM, ODM and trade in CN. &nb... XIGAO Electricenergy Group Co., Ltd is founded in 1993, 320000m2 plant, specialized in manufacturing high & low voltage power transmission and distribution (PTD) equipment, always focusing on the business at collection of research, design, OEM, ODM and trade in CN. &nb...
Get in touch with us
Leave a Message, we will call you back quickly!