Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
Supply Ability | 2000 SET |
Delivery Time | 7-15 DAYS |
Packaging Details | WOODEN CASE |
Name | Manual Vacuum Circuit Breaker |
Installation Location | power plants |
Warranty | 12 months |
OEM | Yes |
Package | exporting standard package |
MOQ | 1set |
Type | Draw Out Type |
life span | More than 15 YEARS |
Brand Name | XG |
Model Number | ZN23 |
Certification | ISO CCC |
Place of Origin | XIAN, China |
View Detail Information
Explore similar products
Electric Operation ZW32 33kv Outdoor 33kv Auto Recloser
ZN85-40.5 3 Phase 33kv 35kv 40.5kv Vacuum Circuit Breaker VCB
ZN23-40.5 3 Phase Indoor 33kv 35kv 40.5kv Air Circuit Breaker
ZW10 12KV 10kv 11kv 630A Outdoor High Voltage Vacuum Circuit Breaker
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram | Supply Ability | 2000 SET |
Delivery Time | 7-15 DAYS | Packaging Details | WOODEN CASE |
Name | Manual Vacuum Circuit Breaker | Installation Location | power plants |
Warranty | 12 months | OEM | Yes |
Package | exporting standard package | MOQ | 1set |
Type | Draw Out Type | life span | More than 15 YEARS |
Brand Name | XG | Model Number | ZN23 |
Certification | ISO CCC | Place of Origin | XIAN, China |
High Light | 40.5kV Manual Vacuum Circuit Breaker ,Draw Out Vacuum Circuit Breaker ,Transmission Vacuum Circuit Breaker |
1. Transmission 40.5kV Manual Vacuum Circuit Breaker Draw Out Type
"Vacuum circuit breaker" is named after its arc extinguishing medium and the insulating medium of the contact gap after arc extinguishing are both high vacuum; it has the advantages of small size, light weight, suitable for frequent operation, and no need for maintenance of arc extinguishing. The application in the network is more popular. Vacuum circuit breaker is an indoor power distribution device in a 3~10kV, 50Hz three-phase AC system,
2. Parameter of air circuit breaker draw out type
NO | Item | Units | Technical parameters | |
1 | Rated voltage | kV | 40.5 | |
2 | Thunder impulse withstand voltage(peak value) | kV | 185 | |
3 | lmin industrial frequency withstand voltage | kV | 95 | |
4 | Rated frequency | Hz | 50 | |
5 | Rated current | A | 1250,1600,2000 | |
6 | Rated short-circuit break current | kA | 25 | 31.5 |
7 | Rated peak value withstand current | kA | 25 | 31.5 |
8 | Rated peak value withstand current | KA | 63 | 80 |
9 | Rated short-circuit duration time | s | 4 | |
10 | Rated short circuit breaking time | ms | ||
11 | Rated short circuit closing current | kA | 80 | |
12 | Rated operation order | 0-0.3s-C0-180s-C0 | ||
13 | Time of closing brake | ms | 50~85 | |
14 | Time of breaking brake | ms | 40~85 | |
15 | Rated short-circuit current break and close times | Times | 20 | |
16 | Mechanical life-span | Times | 10000 | |
17 | Rated dropout current of condenser bank | A | 630 | |
18 | Rated power of energy-storage electric machine | W | 275 | |
19 | Rated volt of energy-storage motor | V | 25 ± 2 | |
20 | Storage time | S | ≤15 | |
21 | Closing and opening solenoid rated voltage | V | ≈220,110 | |
22 | Loss of pressure tripping device rated voltage | V | ≈220,110 | |
23 | Over current tripping device rated current | A | 5 | |
24 | Auxiliary switch rated voltage current | A | DC10 |
3. Working application
Amplitude: earthquake intensity does not exceed 8 °,
Air relative humidity on average less than 95%, on average less than 90%
An ambient air temperature: to +40 °C, the lower limit of -150°C,
Altitude:. ≤ 1000m (For higher altitudes, the rated insulation board level relative increase)
No risk of fire, explosion, serious pollution, chemical corrosion and severe vibration.
4. Technical drawings
5. Factory
6. Delivery
7. FAQ
1. Send the technical data, better for all useful information; we will make a good recommendation.
If possible please attach one reference picture to avoid any misunderstanding or any links from our website for we get a better understanding.
2. The lead time depend on quantity of order. Some standard type is on stock. Otherwise, it will take 3-15 days.
3. Usually shipped by sea, small order or urgent order we can send you by air.
4. All our activities are accredited to ISO 14001:2015 and IEC standard.
Company Details
Business Type:
Manufacturer,Exporter,Seller
Year Established:
1997
Total Annual:
200000000-450000000
Employee Number:
200~300
Ecer Certification:
Verified Supplier
XIGAO Electricenergy Group Co., Ltd is founded in 1993, 320000m2 plant, specialized in manufacturing high & low voltage power transmission and distribution (PTD) equipment, always focusing on the business at collection of research, design, OEM, ODM and trade in CN. &nb... XIGAO Electricenergy Group Co., Ltd is founded in 1993, 320000m2 plant, specialized in manufacturing high & low voltage power transmission and distribution (PTD) equipment, always focusing on the business at collection of research, design, OEM, ODM and trade in CN. &nb...
Get in touch with us
Leave a Message, we will call you back quickly!