Payment Terms | L/C, T/T |
Supply Ability | 10000 pcs per month |
Delivery Time | 3-5 working days |
Packaging Details | Cartons |
Output Power | 1 - 50W |
Output Type | SINGLE |
Input Voltage | 100-240V |
Output Voltage | 9V |
Output Frequency | 50/60Hz |
Output Current | 0.3A |
Operating time | >100000 hours |
Load regulation | +-0.5 |
Brand Name | HLK or OEM |
Model Number | HLK-PM09 |
Place of Origin | China |
View Detail Information
Explore similar products
HLK-PM01 3.3V 5V 9V 12V 24V 600mA 3W AC DC Power Modules
Low Ripple 5w 3.3V 1.5A AC DC Power Supply HLK-5M03
Isolated Switching 5V 5W Step Down Power Supply Module HLK-5M05
Ac Dc 9VDC 5W Line Communication Power Module HLK-5M09
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 10000 pcs per month |
Delivery Time | 3-5 working days | Packaging Details | Cartons |
Output Power | 1 - 50W | Output Type | SINGLE |
Input Voltage | 100-240V | Output Voltage | 9V |
Output Frequency | 50/60Hz | Output Current | 0.3A |
Operating time | >100000 hours | Load regulation | +-0.5 |
Brand Name | HLK or OEM | Model Number | HLK-PM09 |
Place of Origin | China | ||
High Light | 0.3A Switch Power Supply Module ,3W Switch Power Supply Module ,HLK-PM09 |
Input characteristics (test at room temperature 20 ℃).
Rated input voltage: 100-240 VAc
Input voltage range: 90-264 VAc
Maximum input current: ≤0.2 A
Input current surge: ≤10 A
maximum input voltage: ≤270 VAc
Enter slow start: ≤50 mS
Input Low Voltage Efficiency: Vin=110VAc,Output full-load≥69 %
Input High Voltage Efficiency: Vin=220VAc,output full-load≥70 %
Long-term reliability MTBF: ≥100,000 h
Load rated output voltage: +5±0.1 VDc
Full rated output voltage: +5±0.2 VDc
Short-term maximum output current: ≥1000 mA
The maximum output current for a long time: ≥600 mA
Voltage Regulation: ±0.2 %
Load Regulation: ±0.5 %
Output ripple and noise: (mVp-p) ≤50
Rated input voltage, full load. Using 20MHz of bandwidth,
The load side 10uF and 0.1uF capacitor to be tested. mV
Switch overshoot amplitude (Rated input voltage and output load plus 10%)≤5 %VO
Output over-current protection 150-200% of the output maximum load A
Output short circuit protection Direct short circuit at the normal output, automatically resume normal operation after a short circuit removal
Model NO. | Size (mm) | Weight (g) | Output Power (w) | Output Voltage (v) | Output Current (mA) | Efficiency %(TYP) |
HLK-2M03 | 30*16*19 | 18g | 2W | 3.3 | 600 | 69 |
HLK-2M05 | 5 | 400 | ||||
HLK-2M09 | 9 | 230 | ||||
HLK-2M12 | 12 | 170 | ||||
HLK-2M24 | 24 | 84 | ||||
HLK-PM01 | 34*20*15 | 20g | 3W | 5 | 600 | 72 |
HLK-PM03 | 3.3 | 1000 | ||||
HLK-PM09 | 9 | 330 | ||||
HLK-PM12 | 12 | 250 | ||||
HLK-PM24 | 24 | 125 | ||||
HLK-5M03 | 38*23*18 | 32g | 5W | 3.3 | 1500 | 72 |
HLK-5M05 | 5 | 1000 | ||||
HLK-5M09 | 9 | 560 | ||||
HLK-5M12 | 12 | 450 | ||||
HLK-5M24 | 24 | 208 | ||||
HLK-10M03 | 47*28*22 | 40g | 10W | 3.3 | 3000 | 72 |
HLK-10M05 | 5 | 2000 | ||||
HLK-10M09 | 9 | 1100 | 78 | |||
HLK-10M12 | 12 | 830 | ||||
HLK-10M24 | 24 | 416 | ||||
HLK-12M12 | 50.8*25.4*15 | 80g | 12W | 12 | 1000 | 86 |
HLK-20M05 | 57*33*22.5 | 80g | 20W | 5 | 4000 | 80 |
HLK-20M09 | 9 | 2200 | ||||
HLK-20M12 | 12 | 1666 | ||||
HLK-20M15 | 15 | 1300 | ||||
HLK-20M24 | 24 | 833 | 84 | |||
HLK-30M05 | 56*32*22.5 | 80g | 30W | 5 | 6000 | 89 |
HLK-30M09 | 9 | 3300 | 90 | |||
HLK-30M12 | 12 | 2500 | ||||
HLK-30M15 | 15 | 2000 | ||||
HLK-30M24 | 24 | 1250 | ||||
HLK-40M05 | 56*32*22.5 | 80g | 40W | 5 | 8000 | 89 |
HLK-40M09 | 9 | 4400 | 90 | |||
HLK-40M12 | 12 | 3300 | ||||
HLK-40M15 | 15 | 2600 | ||||
HLK-40M24 | 24 | 1600 |
Items | Technical Parameters | Units | Notes |
No-load rated output voltage | 9.0±0.1 | Vdc | |
Full-load tated output voltage | 9.0±0.2 | Vdc | |
Short time maximum output current | ≥430 | mA | |
Long time maximum output current | 330 | mA | |
Voltage regulation | ±0.2 | % | |
Load regulation | ±0.5 | % | |
Input low voltage efficiency | Vin=115Vac, Output full load≥73 | % | |
Input high voltage efficiency | 3Vin=230Vac, Output full load≥73 | % | |
Output ripple and noise (mVp-p) | ≤120 Rated input voltage,output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test | mV | |
Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤5 | %Vo | |
Output over-current protection | Output maximum load 110-150% | A | |
Output short circuit protection | Direct short circuit in normal output and automatic return to nomal operation after removal of short circuit | No-damage to the whole device |
Company Details
Business Type:
Manufacturer
Year Established:
2014
Total Annual:
1000000-2000000
Employee Number:
100~150
Ecer Certification:
Verified Supplier
Lu’s Technology Co., Limited is a Hi-Tech enterprise in China, Which is specialized in the research, design, production and sale of primary lithium battery and rechargeable batteries. Depending on the creative R&D center, the production base and the sale, service net, the company are offer... Lu’s Technology Co., Limited is a Hi-Tech enterprise in China, Which is specialized in the research, design, production and sale of primary lithium battery and rechargeable batteries. Depending on the creative R&D center, the production base and the sale, service net, the company are offer...
Get in touch with us