China factories

China factory - Hunan Heou Engineering Consulting Co., Ltd

Hunan Heou Engineering Consulting Co., Ltd

  • China,Changsha ,Hunan
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Lift Type Stainless Steel Portable Lightning Rod Retractable
China Lift Type Stainless Steel Portable Lightning Rod Retractable

  1. China Lift Type Stainless Steel Portable Lightning Rod Retractable

Lift Type Stainless Steel Portable Lightning Rod Retractable

  1. MOQ: Negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 1000
Delivery Time 8 days
material: Stainless Steel
color: Green
Type: Retractable lightning rod
Brand Name HAMMOND
Model Number HD-168
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 1000
Delivery Time 8 days material: Stainless Steel
color: Green Type: Retractable lightning rod
Brand Name HAMMOND Model Number HD-168
Certification ISO9001 Place of Origin China
High Light Portable Lightning Rod RetractableStainless Steel Portable Lightning Rod RetractableLift Type Lightning Pole Retractable

Retractable Lightning Rod Lift Type Portable Lightning Rod

Including: common lightning rod head, retractable bracket 1, installation accessories and side bracket 1 set

 

 

Lightning conductors and grounding precautions[edit]

Ideally, the underground part of the assembly should reside in an area of high ground conductivity. If the underground cable is able to resist corrosion well, it can be covered in salt to improve its electrical connection with the ground. While the electrical resistance of the lightning conductor between the air terminal and the Earth is of significant concern, the inductive reactance of the conductor could be more important. For this reason, the down conductor route is kept short, and any curves have a large radius. If these measures are not taken, lightning current may arc over a resistive or reactive obstruction that it encounters in the conductor. At the very least, the arc current will damage the lightning conductor and can easily find another conductive path, such as building wiring or plumbing, and cause fires or other disasters. Grounding systems without low resistivity to the ground can still be effective in protecting a structure from lightning damage. When ground soil has poor conductivity, is very shallow, or non-existent, a grounding system can be augmented by adding ground rods, counterpoise (ground ring) conductor, cable radials projecting away from the building, or a concrete building's reinforcing bars can be used for a ground conductor (Ufer ground). These additions, while still not reducing the resistance of the system in some instances, will allow the [dispersion] of the lightning into the earth without damage to the structure.[15]

Additional precautions must be taken to prevent side-flashes between conductive objects on or in the structure and the lightning protection system. The surge of lightning current through a lightning protection conductor will create a voltage difference between it and any conductive objects that are near it. This voltage difference can be large enough to cause a dangerous side-flash (spark) between the two that can cause significant damage, especially on structures housing flammable or explosive materials. The most effective way to prevent this potential damage is to ensure the electrical continuity between the lightning protection system and any objects susceptible to a side-flash. Effective bonding will allow the voltage potential of the two objects to rise and fall simultaneously, thereby eliminating any risk of a side-flash.[16]

Lightning protection system design[edit]

Considerable material is used to make up lightning protection systems, so it is prudent to consider carefully where an air terminal will provide the greatest protection. Historical understanding of lightning, from statements made by Ben Franklin, assumed that each lightning rod protected a cone of 45 degrees.[17] This has been found to be unsatisfactory for protecting taller structures, as it is possible for lightning to strike the side of a building.

A modeling system based on a better understanding of the termination targeting of lightning, called the Rolling Sphere Method, was developed by Dr Tibor Horváth. It has become the standard by which traditional Franklin Rod systems are installed. To understand this requires knowledge of how lightning 'moves'. As the step leader of a lightning bolt jumps toward the ground, it steps toward the grounded objects nearest its path. The maximum distance that each step may travel is called the critical distance and is proportional to the electric current. Objects are likely to be struck if they are nearer to the leader than this critical distance. It is standard practice to approximate the sphere's radius as 46 m near the ground.[18]

An object outside the critical distance is unlikely to be struck by the leader if there is a solidly grounded object within the critical distance. Locations that are considered safe from lightning can be determined by imagining a leader's potential paths as a sphere that travels from the cloud to the ground. For lightning protection, it suffices to consider all possible spheres as they touch potential strike points. To determine strike points, consider a sphere rolling over the terrain. At each point, a potential leader position is simulated. Lightning is most likely to strike where the sphere touches the ground. Points that the sphere cannot roll across and touch are safest from lightning. Lightning protectors should be placed where they will prevent the sphere from touching a structure. A weak point in most lightning diversion systems is in transporting the captured discharge from the lightning rod to the ground, though.[19] Lightning rods are typically installed around the perimeter of flat roofs, or along the peaks of sloped roofs at intervals of 6.1 m or 7.6 m, depending on the height of the rod.[20] When a flat roof has dimensions greater than 15 m by 15 m, additional air terminals will be installed in the middle of the roof at intervals of 15 m or less in a rectangular grid pattern.[21]

 

 

Retractable lightning rod lift type lightning rod portable lightning rod

 

NO Technical indicators Technical performance Description
1 section number 8 material aluminum magnesium alloy 6063B/T5+6063B/T5+
2 Receiver type electric prevention type ptimization type Franklin type default 0.5 m Franklin type
3 end section of aluminum tube inner diameter with Φ34mm two anti-rotation tendons

 

Retractable lightning rod lift type lightning rod portable lightning rod

 

 

Retractable lightning rod lift type lightning rod portable lightning rod

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler,Agent,Importer,Exporter,Trading Company,Seller,Other

  • Year Established:

    2002

  • Total Annual:

    3000000-3500000

  • Employee Number:

    100~500

  • Ecer Certification:

    Active Member

  ecer({videoId:"hj3UYUjLwxU",idContainer:"#YBgmpwj"}) Company Information Company Profile Hunan Hertz-Ohm Engineering Group Co., Ltd. (referred to as Hunan Heou) is a comprehensive engineering consulting company established in Changsha in cooperation w...   ecer({videoId:"hj3UYUjLwxU",idContainer:"#YBgmpwj"}) Company Information Company Profile Hunan Hertz-Ohm Engineering Group Co., Ltd. (referred to as Hunan Heou) is a comprehensive engineering consulting company established in Changsha in cooperation w...

+ Read More

Get in touch with us

  • Reach Us
  • Hunan Heou Engineering Consulting Co., Ltd
  • 618, Goodbond Venture Base, No.18, Lu Yun Road, Yue Lu District, Changsha City, Hunan Province
  • https://www.lightninggrounding.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement