Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"1.8m Height Early Discharge Lightning Rod , ESE Lightning Conductor Active","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/07\/3b\/4f3599ce784b3f382ea8dbedbe94-200x200-1\/1_8m_height_early_discharge_lightning_rod_2c_ese_lightning_conductor_active.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HD-Y","Place of Origin":"CHINA","Minimum Order Quantity":"5"}}
{"title":"OEM ESE Stainless Steel Lightning , Spike Rod Arrester For Gas Station","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/07\/3b\/4f3599ce784b3f382ea8dbedbe94-200x200-1\/oem_ese_stainless_steel_lightning_2c_spike_rod_arrester_for_gas_station.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HD-Y","Place of Origin":"CHINA","Minimum Order Quantity":"5"}}
{"title":"ISO9001:2008 Ornamental Residential Lightning Rods For Protection","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/aa\/64\/ace62d094d427f8abf393ee6e6d6-200x200-1\/iso9001_3a2008_ornamental_residential_lightning_rods_for_protection.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HD-ZZ","Place of Origin":"China","Minimum Order Quantity":"Negotiable"}}
{"title":"IEC 62305-3 Stainless Steel Lightning Rod On Buildings Outdoor","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/78\/2e\/b5b179887fa22e8ac452fb6b795d-200x200-1\/iec_62305_3_stainless_steel_lightning_rod_on_buildings_outdoor.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HD-Y","Place of Origin":"CHINA","Minimum Order Quantity":"5"}}
{"title":"ESE Stainless Steel Lightning Rod","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/b3\/8f\/e18f03d7d7431c1307fb786d4ddc-200x200-1\/ese_stainless_steel_lightning_rod.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HDB-IF3","Certification":"ISO9001","Place of Origin":"China"}}
{"title":"Single Pin Stainless Steel Lightning Rod","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/32\/f6\/3e62d9e95cb3f09c5a7930ac0a61-200x200-1\/single_pin_stainless_steel_lightning_rod.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HD-TE01","Place of Origin":"China","Minimum Order Quantity":"Negotiable"}}
{"title":"SUS304 Active Lightning Rod","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/7e\/37\/0060348411064d6f18f7f117361b-200x200-1\/sus304_active_lightning_rod.jpg","attrs":{"Brand Name":"HAMMOND","Model Number":"HDB-4","Certification":"ISO9001","Place of Origin":"China"}}
Hot Sale Stainless Steel Lightning Rod French Original ESE6000 Lightning Rod Outdoor Discharge physics
Discharge physics shows that conventional Franklin lightning rods require a delay time to produce upward gravitational force, and this delay time can limit the effectiveness of vertical or horizontal lightning rods.
Introduction of products
This excitation device integrated in the air terminal is designed to increase the excitation distance and thus generate the ascending tracer earlier(regarding to an ascending tracer naturally emitted by a simple rod. All of our early streamer emission systems are tested in compliance with NF C 17-102 standard,edition September 2011.
These 3 main parts are the components of the lightning protection system.
This conductor will usually run outside the structure.Each fixing should allow an eventual conductor dilatation.Bend radius have to be inferior to 0.2 meters.Metalli-cal masses situated in the zone of separation calculated beforehand will be interconnected equipotentially to the lightning conductor.Each down conductor will be equipped at the bottom with a control junction and a 2 meter-high mechanical protective tube.
The capturing device with its supporting mast and fixings. .The down conductor composed of one or several tin-ned copper tape with section in compliance with stan-dards in force,designed to flow the lightning current of the lightning conductor to the earthing system.
The earthing system with an adapted form in com-pliance with standards in force has for aim to diffuse the lightning current to the ground.An inspection pit will be installed to do the equipotential connection with the nearest electrical earth netword of the building. Installation quality of a lightning system is an impor-tant element ofr the efficiency of a lightning protection system. For each installation and in most of cases it will be bet-ter to start with the installation of the earthing sys-tems,then as direct as possible channels of each down conductor,then finish with the lightning conductor and roof circuit installation.
ecer({videoId:"hj3UYUjLwxU",idContainer:"#YBgmpwj"})
Company Information
Company Profile
Hunan Hertz-Ohm Engineering Group Co., Ltd. (referred to as Hunan Heou) is a comprehensive engineering consulting company established in Changsha in cooperation w...
ecer({videoId:"hj3UYUjLwxU",idContainer:"#YBgmpwj"})
Company Information
Company Profile
Hunan Hertz-Ohm Engineering Group Co., Ltd. (referred to as Hunan Heou) is a comprehensive engineering consulting company established in Changsha in cooperation w...