Payment Terms | T/T, L/C, Western Union, D/A, D/P, MoneyGram, PayPal |
Supply Ability | 3,000pcs per month |
Delivery Time | 20 working days after received your payment |
Packaging Details | wooden case |
Product Name | Maintenance Free Horizontal Double-Break Disconnector With Drive Mechanism |
Max. Voltage | 252KV |
Condition | Outdoor |
Standard | IEC 62271-102: 2005 IEEE Std C37.30-1997 |
Brand name | YongDe |
Warranty | 12 month |
Brand Name | YONGDE |
Model Number | GW38 |
Certification | ISO9001, veiki |
Place of Origin | Zhejiang,China(Mainland) |
View Detail Information
Explore similar products
High Voltage Double Earthing Substation Disconnect Switches Three Phase Simple
Three Post High Voltage Disconnect Switch Double Break Type Disconnector
252KV 3 Pole High Voltage Disconnectors / Hv Disconnect Switches With Drives For
Three Phase High Voltage Switch Gear With Motor For Switch Yard GW37-252
Product Specification
Payment Terms | T/T, L/C, Western Union, D/A, D/P, MoneyGram, PayPal | Supply Ability | 3,000pcs per month |
Delivery Time | 20 working days after received your payment | Packaging Details | wooden case |
Product Name | Maintenance Free Horizontal Double-Break Disconnector With Drive Mechanism | Max. Voltage | 252KV |
Condition | Outdoor | Standard | IEC 62271-102: 2005 IEEE Std C37.30-1997 |
Brand name | YongDe | Warranty | 12 month |
Brand Name | YONGDE | Model Number | GW38 |
Certification | ISO9001, veiki | Place of Origin | Zhejiang,China(Mainland) |
High Light | high voltage disconnectors ,high voltage isolator switch |
Maintenance Free Horizontal Double-Break Disconnector With Drive Mechanism
Description of GW38 series:
GW38-40.5~252/630~4000 Type Three post Horizontal Double break disconnector
Double break is good for reducing the distance and station arranging, especially for indoor station.
Because of electric rod's self-rotation and switching structure and having self-locking function, it has strong property of motor performance resistance. Meanwhile, it can resist motor, wind pressure, earthquake and other outside power.
Contact and finger's on and off way is sliding rotation, having strong self-clean ability.
In the galvanic circle, the section is the combination structure made by screw fix linking, having the good property of stable flowing, high reliability, simple change way and convenient adding volume way.
In the galvanic circle, the contact and finger is made by T2Y pure copper tap whose connecting part is coated by 30μ M silver.
Finger spring is made by the stainless steel and its design is the inside hiding and outside press structure which is convenient for testing and changing.
The bearing has changed from the bevel rear structure to the Universal connecting rod drive structure, having the advantage of simple structure, high intensity, convenient operation way and safety enough.
Bearing block is made by high-intensity casting steel (disposed by hot zinc coating), the height can be adjusted and have the function of damping.
Have different install way such as front install, side install, back install and leak 25° Install and so on, adapting to different station entering line ways.
All the operating rod and linking rod are supplied by manufacturer, which is convenient for loading, adjusting and testing.
It can be supplied as a whole above the ground according to user's requirement.
Parameter Table | |||||
No | Items | Technical parameter | |||
1 | Rated Voltage kV | 72.5 | 126 | 252 | |
2 | Nominal system voltage kV | 66 | 110 | 220 | |
3 | Rated current A | 630;1250;1600;2000;2500;3150;4000 | |||
4 | Rated Short Time withstand current and Time kA/s | 25~50/4 | |||
5 | Rated Peak withstand current kA | 63~125 | |||
6 | 1min power frequency withstand voltage (effective value) kV | To earth | 140 | 230 | 460 |
To phase | 140 | 2300 | 460 | ||
Across Isolating DS | 180 | 230+70 | 460+145 | ||
7 | Lightning Impulse wishstand voltage(peak value) KV | To earth | 325 | 550 | 1050 |
To phase | 325 | 500 | 1050 | ||
Across Isolating DS | 385 | 550+100 | 1050+150 | ||
8 | Rated mechanical terminal load N | Level of lateral load | 750 | 1500 | 2000 |
Level of vertical load | 500 | 1000 | 1500 | ||
Vertical | 750 | 1000 | 1250 | ||
9 | The min distance of insulation against ground mm | 600 | 1000 | 2000 | |
10 | Max Man Operative Moment N. m | 200 | |||
11 | Motor Drive operating mechanism control voltage V | AC220,380; DC110,220 | |||
12 | Motor Drive operating mechanism motor voltage V | AC220,380; DC110,220 |
The disconnectors and earthing switches are designed and tested in accordance with latest IEC specifications.
Company Details
Business Type:
Manufacturer
Year Established:
1993
Total Annual:
$17,364,156-$20,744,408
Employee Number:
100~250
Ecer Certification:
Verified Supplier
Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. As a high-new-tech enterprise in Zhejiang province, it is about 15 kilometers from downtown area. Our Company is one of the recommended model companies for national power grid construction and transformation. We specialize... Hangzhou Yongde Electric Appliances Co.,Ltd was founded in 1993. As a high-new-tech enterprise in Zhejiang province, it is about 15 kilometers from downtown area. Our Company is one of the recommended model companies for national power grid construction and transformation. We specialize...
Get in touch with us
Leave a Message, we will call you back quickly!