China factories

China factory - Dingneng (China) building materials Co., Ltd

Dingneng (China) building materials Co., Ltd

  • China,Langfang ,Hebei
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China 20ga Thickness Metal Drywall Structural Steel Studs
China 20ga Thickness Metal Drywall Structural Steel Studs

  1. China 20ga Thickness Metal Drywall Structural Steel Studs
  2. China 20ga Thickness Metal Drywall Structural Steel Studs

20ga Thickness Metal Drywall Structural Steel Studs

  1. MOQ:
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram
Thickness: 33 mils (20ga), 43 mils (18ga), 54 mils (16ga), 68 mils (14ga) and 97 mils (12ga).
Flange Sizes: 1-3/8”, 1-5/8”, 2”, 2-1/2”, 3”.
name structural steel studs
keyword structural steel studs
Place of Origin Beijing China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, D/A, D/P, T/T, Western Union, MoneyGram Thickness: 33 mils (20ga), 43 mils (18ga), 54 mils (16ga), 68 mils (14ga) and 97 mils (12ga).
Flange Sizes: 1-3/8”, 1-5/8”, 2”, 2-1/2”, 3”. name structural steel studs
keyword structural steel studs Place of Origin Beijing China
High Light 20ga structural steel studs20ga structural metal studsdrywall structural steel studs

COLD-FORMED STEEL C-STUDS 

Cold-Formed / Light-Gauge C-shaped framing members for axial loadbearing walls, curtain walls, tall interior partitions, floor joists and roof truss assembli

 

Typically Gypsum board frame is used for interior walls but the use of structural framing may be needed to meet taller requirements. Interior nonstructural (non-load bearing) walls calculated in the Structual Stud Lookup Tool and Limit height  are limited to a superimposed axial load, exclusive of sheathing materials, of not more than 100 lb/ft, or a superimposed axial load of not more than 200 lbs.

Lateral Load / Design Load

Nonstructural (Non-load bearing) interior walls must be designed to withstand a minimum of 5 psf lateral load (perpendicular to the wall) for interior pressure as required by the International Building Code. Check your projects Architectural Specifications and/or drawings for the minimum design load required. Loads of 7.5psf and 10psf are typically used for shaftwalls or interior lobby walls located in floors with multiple exterior doors.

Deflection

The main purpose of specifying an allowable stud lateral deflection for interior wall framing is actually for determining what is an acceptable deflection for the wall facing materials. Sheathing and Finish materials require a minimum stiffness to prevent cracking. The required stiffness for the finish material is achieved by the specified deflection limit. Check with your projects Architectural Specifications and/or drawings for the lateral deflection required for a given wall facing material. Interior walls typically require a minimum lateral deflection of L/240. Some finishes such as tile or thin stone may require a higher deflection limit like L/360 or even L/600. We do not recommend using L/120 for walls taller than 10 feet.

For example a 10’ wall at L/120 (L = Length in inches, divided by 120) could have a lateral deflection of (10x12/120) = 1"

Limiting Heights

Limiting heights are based on continuous lateral support (gypsum wallboard) on each flange over the full height of the stud. If wallboard does not run the full height of the stud, lateral bracing may be required. Contact ClarkDietrich Technical Services to help determine spacing of the lateral bracing above the wallboard.

See all design notes on the bottom of the lookup tool and tables.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2011

  • Total Annual:

    2,500,000-5,000,000

  • Employee Number:

    100~120

  • Ecer Certification:

    Verified Supplier

China Dingneng provides comprehensive products and services for cold-formed steel frames and drywall systems. Dingneng is located in the center of Beijing, Tianjin and Shijiazhuang. It is a lime slab frame structure as its main product. Our factory has an advantageous geographical location, adjacent... China Dingneng provides comprehensive products and services for cold-formed steel frames and drywall systems. Dingneng is located in the center of Beijing, Tianjin and Shijiazhuang. It is a lime slab frame structure as its main product. Our factory has an advantageous geographical location, adjacent...

+ Read More

Get in touch with us

  • Reach Us
  • Dingneng (China) building materials Co., Ltd
  • Wen'an County, Langfang City, Hebei Province, China
  • https://www.lightgaugesteelstuds.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement