China factories

China factory - HEFEI ECOLITE ENERGY CO., LTD.

HEFEI ECOLITE ENERGY CO., LTD.

  • China,Hefei ,Anhui
  • Verified Supplier

Leave a Message

we will call you back quickly!

Submit Requirement
China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64
China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64

  1. China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64
  2. China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64
  3. China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64
  4. China Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64

Ecolite High Voltage BMS Battery Management System For Energy Storage BMU64

  1. MOQ: 100 system
  2. Price: Inquiry
  3. Get Latest Price
Payment Terms L/C, T/T
Supply Ability 2000 Units per month
Delivery Time 1-2 months
Packaging Details Carton Pallet Container
Working voltage range S50mA(12V)/s25mA(24V)
CAN communication 1 Channel
Single cell detection range 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage
Voltage acquisition accuracy ±5mV
Temperature detection accuracy ±2°C ±2°C
Balance function Support, passive balancing
Balanced number of opening routes Every 8 channels can activate 1 channel equalization
Digital signal power input Max120mA,effective value 30-50mA
Automatic address allocation Support
Io output 2-way dry contact, rated 2A, passive output
Bootloader Support CAN bus burning and writing
Anti reverse connection of power supply Support
Power surge prevention Support
Brand Name Ecolite/OEM/ODM
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms L/C, T/T Supply Ability 2000 Units per month
Delivery Time 1-2 months Packaging Details Carton Pallet Container
Working voltage range S50mA(12V)/s25mA(24V) CAN communication 1 Channel
Single cell detection range 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage Voltage acquisition accuracy ±5mV
Temperature detection accuracy ±2°C ±2°C Balance function Support, passive balancing
Balanced number of opening routes Every 8 channels can activate 1 channel equalization Digital signal power input Max120mA,effective value 30-50mA
Automatic address allocation Support Io output 2-way dry contact, rated 2A, passive output
Bootloader Support CAN bus burning and writing Anti reverse connection of power supply Support
Power surge prevention Support Brand Name Ecolite/OEM/ODM
Place of Origin China
High Light High Voltage Battery Management SystemBMS Battery Management SystemOEM High Voltage BMS

Ecolite Highly Functional Level 3 High Voltage Battery Management System for Energy Storage BMU64

Diagram of Energy storage Level 3 Architecture System:
Level 3 battery system architecture: First level control: BAU centrally man-ages the various clusters of batteries inthe battery array, and communicateswith external PCS, UPS, EMS, airconditioning, liquid cooling, fire protec-tion, etc;
Secondary control: BCU1~BCUmmanaging each cluster of batteriescollecting cluster battery information,high-voltage control, and uploadingcluster information to BAU;

Slave control:BMU1~BMUn, responsi-ble for collecting battery voltage,temperature and otherinformation ofthe battery module.

Products Function configuration
BCU Parameter MinimumValue TypicalValue Maximum UnitValue Description
Power input 9 24 32 v  
Working current 180 125 130 mA  
Rated power     S3 W  
CAN BuS     3 Channel 2-wayisolation,1-way non isolation
485 Bus     2 Channel 2-way isolation
LAN interface (TCP/P)     1 Channel  
High edge output     8+2 Channel 2-way support for PWM output
Switching input detection     9 Channel solaed acise dee prosive detection, 1 -way
Dry node output     2 Channel Rated 2A, passive output
Temperature detection     4 Channel +2℃℃,-40~125°℃,supports NTC-10K,100K
Total voltage detection channel     3 Channel 1 channel supports main and negative relayadhesion detection
Total voltage detection range 12   1500 V Total pressure detection error ≤ 0.3%
Manage the rated voltage ofthe battery pack   1500   V Rasrocltage ssoy, withstand voltage
AC3100+,DC4380+
Supports the number of BMU     40 PCS  
Detect the total 6   500 Strand Used in
Number of battery strings         Conjunction with BMU
Current detection     2 Channel Supports 1 splitter,1 Hall(supports 5v,12v),
and can collect data simultaneously
Current detection range -1500   1500 A Range optional
Current detection error 0 1 1%FSR A Typical error 0.5% FSR, maximum error 1% FSR
Insulation testing     15% 0-200KΩ,error<15KΩ;>200KΩ,eror≤+15%
BCU automatic addressing   support     lsolation type, level signal addressed
SOC estimation error 0 3% 5%   ≤5%
SOH estimation accuracy 0 3% 10%    
SOE estimation accuracy 0 3% 5%    

 

Products Function configuration
BAU Parameter MinimumValue TypicalValue Maximum UnitValue Description
Power input 9 24 32 v  
Working current 180 200 220 mA  
Rated power     ≤5 W  
CAN Bus     4 Channel lsolation communication
485 Bus     4 Channel lsolation communication
USB interface     1 Channel Used for external data storage, default 32/64G
LAN interface (TCP/IP)     2 Channel  
Relay drive output (RL)     4 Channel  
Dry node output (DO)     4 Channel Rated 2A, passive dry node
Digital Input (DlH)     2 Channel High level detection
Digital Input (DlL)     2 Channel Low level detection
Digital signal power input     1 Channel lsolation signal detection power supply
Supports the number of BCU     30 PCS  

 

Products   Function configuration
BMU Parameter BMU16 BMU32 BMU48 BMU64
Working voltage range 9~32V
Working voltage range S50mA(12V)/s25mA(24V)
Rated power ≤0.6W
CAN communication 1 Channel
Number of voltage acquisitionstrings 16 32 48 64
Temperature detection point 4 8 12 16
Single cell detection range 0-5000mV; Exceeding the range of -0.5~6V can cause AFE damage
Voltage acquisition accuracy ±5mV
Temperature detection accuracy ±2°C ±2°C
Balance function Support, passive balancing
Balanced number of opening routes Every 8 channels can activate 1 channel equalization
Digital signal power input Max120mA,effective value 30-50mA
Automatic address allocation Support
Io output 2-way dry contact, rated 2A, passive output
Analog input detection 2-way (high edge detection)
Bootloader Support CAN bus burning and writing
CAN communication 1 Channel
Anti reverse connection of power supply Support
Power surge prevention Support
Voltage resistance Voltage withstand AC3100+,DC4380+
Working temperature -40°C~85°C
Storage temperature -40°C~125°C
Protection level IP43, Not waterproof
Humidity <95%,No condensation
Shock ≤5500m
Automatic address allocation At 10-25Hz,the amplitude is 1.2mm: At 26-500Hz,maximum 30m/S
Drop 1.5m, 5 times in both horizontal and vertical directions, no damage to PCBA, no change in performance

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2014

  • Total Annual:

    10,000000-15000000

  • Employee Number:

    50~80

  • Ecer Certification:

    Verified Supplier

Hefei Ecolite Energy Co., Ltd., founded in 2014,is a China leading manufacturer who specialized in R&D,production,sales and technology support of Lithium battery (LFP and LTO) and BMS. We provide full solution for your battery inquiry.One-stop service from battery design to delivery.  ... Hefei Ecolite Energy Co., Ltd., founded in 2014,is a China leading manufacturer who specialized in R&D,production,sales and technology support of Lithium battery (LFP and LTO) and BMS. We provide full solution for your battery inquiry.One-stop service from battery design to delivery.  ...

+ Read More

Get in touch with us

  • Reach Us
  • HEFEI ECOLITE ENERGY CO., LTD.
  • Building 4,No.33,Qiuju Road,Boyan Science Park, high tech Zone,Hefei City,Anhui Province,China P.C 230000
  • https://www.lifepo4-lithiumbatteries.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement