China factories

China factory - Chongqing Leeb Instrument Co.,Ltd

Chongqing Leeb Instrument Co.,Ltd

  • China,Chongqing ,Chongqing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Changeable Ferrous Probe Automotive Paint Thickness Gauge For Magnetoresistance
China Changeable Ferrous Probe Automotive Paint Thickness Gauge For Magnetoresistance

  1. China Changeable Ferrous Probe Automotive Paint Thickness Gauge For Magnetoresistance

Changeable Ferrous Probe Automotive Paint Thickness Gauge For Magnetoresistance

  1. MOQ: 1 Set
  2. Price: Based on quantity
  3. Get Latest Price
Payment Terms T/T, PayPal, Western Union, L/C
Supply Ability 500 sets per month
Delivery Time In 7-10 work days
Packaging Details Equipment Box
Name Magneto-resistance thickness gauge
Application on Ferrous metal
Principle Magnetic measurement
Shell Metal shell
Probe Changeable
Memory 300 groups
Brand Name LEEB
Model Number Leeb230
Certification CE, FCC EAC & ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, PayPal, Western Union, L/C Supply Ability 500 sets per month
Delivery Time In 7-10 work days Packaging Details Equipment Box
Name Magneto-resistance thickness gauge Application on Ferrous metal
Principle Magnetic measurement Shell Metal shell
Probe Changeable Memory 300 groups
Brand Name LEEB Model Number Leeb230
Certification CE, FCC EAC & ISO Place of Origin China
High Light Leeb 230 Automotive Paint Thickness GaugeLeeb 230 Paint Thickness GaugeLEEB Automotive Paint Thickness Gauge

Changeable Ferrous Probe Automotive Paint Thickness Gauge For Magnetoresistance

 

High Accuracy Changeable Ferrous Probe & Metal Shell Coating Thickness Gauge For Magneto-Resistance

 

 

Functions & Features

 

1)  Software for PC connection and data analysis

2)  High quality metal sheel
3)  With back-light
4)  Easy operation: Switch off automatically or manually.
5)  With five calibration specimens: 1024μm,513μm,249μm 99.8μm,48.5μm)

 

 

Technical Parameters

 

Technical Parameters
Model No. Leeb230
Measuring principle Fe
Measuring range (µm) 0~1250μm
Probe Changeable
Shell Metal
Accuracy ±(1~3%H+1) μm; H refers to the thickness of testing piece
Minimum resolution (µm) 0.1μm
Min curvature of the min area (mm) Convex1.5 Concave9
Diameter of the min area (mm) Φ7
Critical thickness of substrate (mm) 0.5
Memory 300 groups measured data
Dimensions 115*70*30mm
Power supply AAA Alkaline battery
Standard Configuration Main Machine, 1 probe & substrate*1,

5 calibration specimens (48.5μm,99.8μm,249μm,513μm,1024μm)

Optional Accessories Probes,Specimens

 

 
Measuring Principle
 
Magnetic measurement method (With Fe Probe)
 
Measuring Non-magnetic coatings on magnetic substrates (such as aluminum, chromium, copper, rubber coatings on steel, iron, alloy and hard magnetic steel substrates).
When the probe contact with cover, measuring probe and magnetic metal matrix form a closed magnetic circuit, as a result of the existence of a non-magnetic layer, make the magnetic circuit magnetic resistance change, can be derived by measuring the change the thickness of coating.
 
 
Substrate
 
a) Standard methods for magnetic substrate metal magnetic properties and surface roughness, tested should stay with the substrate metal magnetic and surface roughness is similar.For eddy current method, standard pieces of the electrical properties of the metal matrix, and the tested should stay with the substrate similar to the electrical properties of the metal.To confirm the applicability of the standard piece, available
standard piece of base metal and under test on a substrate metal comparing measured by the readings.
 
b) If under test pieces of metal substrate thickness is no more than the critical thickness stipulated in the table 1, the following two methods can be used for calibration:
 
  1) Stay with the same test pieces of metal substrate thickness metal on-chip calibration standard;
  2) With a sufficient thickness, electrical properties of similar metal liner metal standard or specimen, but it must be made between base metal and liner metal without clearance. On the two sides have cladding specimens, cannot use liner method.
 
c) If the curvature of the coating under test has reached the calibration can't on the plane, have the covering layer of the curvature of the standard piece or of the curvature of the substrate metal under calibration foils, shall be the same with the curvature of the specimen.

 

 

5 calibration specimens (48.5μm,99.8μm,249μm,513μm,1024μm)

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2001

  • Total Annual:

    7500000-12000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Chongqing Leeb Instrument Co.,Ltd, the largest NDT instruments factory in the southwest of China, located at High-tech Industrial Development Zone of Chongqing, China. We specialize in manufacturing, researching and marketing of NDT Instruments, including various kinds of Hardness Tester, Thickness ... Chongqing Leeb Instrument Co.,Ltd, the largest NDT instruments factory in the southwest of China, located at High-tech Industrial Development Zone of Chongqing, China. We specialize in manufacturing, researching and marketing of NDT Instruments, including various kinds of Hardness Tester, Thickness ...

+ Read More

Get in touch with us

  • Reach Us
  • Chongqing Leeb Instrument Co.,Ltd
  • High&New Technology Industrial Park, Yubei District, Chongqing, China
  • https://www.leebtester.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!