China factories

China factory - Chongqing Leeb Instrument Co.,Ltd

Chongqing Leeb Instrument Co.,Ltd

  • China,Chongqing ,Chongqing
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Leeb231 1250µm Metal Shell Coating Thickness Gauge For Eddy Current
China Leeb231 1250µm Metal Shell Coating Thickness Gauge For Eddy Current

  1. China Leeb231 1250µm Metal Shell Coating Thickness Gauge For Eddy Current

Leeb231 1250µm Metal Shell Coating Thickness Gauge For Eddy Current

  1. MOQ: 1 Set
  2. Price: Based on quantity
  3. Get Latest Price
Payment Terms T/T, PayPal, Western Union, L/C
Supply Ability 500 sets per month
Delivery Time In 7-10 work days
Packaging Details Equipment Box
Name paint thickness gauge
Application on Non-Ferrous metal
Principle Eddy current
Shell Metal
Memory 300 groups measured data
Range (µm) 0~1250
Brand Name LEEB
Model Number Leeb231
Certification CE, FCC EAC & ISO
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, PayPal, Western Union, L/C Supply Ability 500 sets per month
Delivery Time In 7-10 work days Packaging Details Equipment Box
Name paint thickness gauge Application on Non-Ferrous metal
Principle Eddy current Shell Metal
Memory 300 groups measured data Range (µm) 0~1250
Brand Name LEEB Model Number Leeb231
Certification CE, FCC EAC & ISO Place of Origin China
High Light 1250µm Coating Thickness GaugeLeeb231 Coating Thickness GaugeLeeb 231 Thickness Gauge

Leeb231 1250µm Metal Shell Coating Thickness Gauge For Eddy Current

 

High Precision Changeable NFe Probe Metal Shell Coating Thickness Gauge For Eddy Current

 

 

Functions & Features

As the hot-sale item with  Changeable NFe probes and back-light screen.

This equipment(Leeb231) has two softward for PC connection and data analysis
User can switch off automatically or manually, and set the limit according to the different request.

 

 

Technical Parameter

Technical Parameters
Model No. Leeb231
Measuring principle NFe
Measuring range (µm) 0~1250μm
Probe Changeable
Shell Metal
Accuracy ±(1~3%H+1) μm; H refers to the thickness of testing piece
Minimum resolution (µm) 0.1μm
Min curvature of the min area (mm) Convex1.5 Concave9
Diameter of the min area (mm) Φ7
Critical thickness of substrate (mm) 0.5
Memory 300 groups measured data
Dimensions 115*70*31mm
Power supply AAA Alkaline battery
Standard Configuration Main unit, 1 probe & substrate,

5 calibration specimens (48.5μm,99.8μm,249μm,513μm,1024μm)

Optional Accessories Probes,Specimens

 

 
Basic Calibration Correction
     Basic calibration in the following cases, the change is necessary:
     -The probe frayed at the top.
     -Replace a new probe.
     -Special purpose.
     In measuring, if error is clearly beyond the scope, should be made for the
     properties of the probe to the calibration is called basic calibration.
     By entering the six calibration values (a thickness of zero and five values), can realign the measuring head.
     
 
Steps of basic calibration;
Step 1: Under normal condition, continuous press “Clear” three times;
Step 2: Press“Menu”and up & down key to select“Calibrate”,press“Menu”to into the correct Zero;
Step 3: Place the probe vertically in the middle of the matrix and hold still; after completion of shows such as 5 seconds away again.To the next.
Step 4: When show the“S1”(The first specimens),put the minimum value (48.5 μm)specimens on the standard substrate,probe vertically on the S1 hold still,
such as display again after 5 seconds.Display real thickness“Real thickness(0049.4μm)”,press“Menu”and up & down key to select to enter the value
from“(0049.4 μm)”to the real one“(0048.5 μm)” and go to the next;
Step 5: Display“S2”,remove“S1”,put ( 99.8μm)piece on the standard
substrate,probe vertically on the S2 hold still, such as display again after 5 seconds,display“real thickness(0096.7μm)”,press“Menu”and up & down key to select to enter the value from“(0096.7 μm)”to the real one“(0099.8um)”and go to the next;
Step 6: Use“Step 5”to complete the real value calibration of“S3(249μm),S4(513μm),S5(1024μm)”
Step 7: After calibrate S5will display“Loading...”,about 2 seconds later it will come back to boot interface.Measured again after 5 seconds, such as standard substrate(Or you will enter the continuous mode),correct Zero to ensure that the display value to 0 after the test piece (or measured values are not accurate). The basic calibration complete.
 
        Note:Specimens with other basic calibration, on the specimens of each thickness should be at least 1.6 times the thickness of a specimen.Such as:20,50, 100,250,500μm.
        After the calibration, the instrument will work according to the new calibration value.
 
 

High quality Equipment Box:

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Seller

  • Year Established:

    2001

  • Total Annual:

    7500000-12000000

  • Employee Number:

    100~200

  • Ecer Certification:

    Active Member

Chongqing Leeb Instrument Co.,Ltd, the largest NDT instruments factory in the southwest of China, located at High-tech Industrial Development Zone of Chongqing, China. We specialize in manufacturing, researching and marketing of NDT Instruments, including various kinds of Hardness Tester, Thickness ... Chongqing Leeb Instrument Co.,Ltd, the largest NDT instruments factory in the southwest of China, located at High-tech Industrial Development Zone of Chongqing, China. We specialize in manufacturing, researching and marketing of NDT Instruments, including various kinds of Hardness Tester, Thickness ...

+ Read More

Get in touch with us

  • Reach Us
  • Chongqing Leeb Instrument Co.,Ltd
  • High&New Technology Industrial Park, Yubei District, Chongqing, China
  • https://www.leebtester.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement