Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
Supply Ability | 300 Sets per Month |
Delivery Time | 20 days after order confirmed |
Packaging Details | each set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
Output Power | 24kw |
Input Current | 42.9A/Phase |
Noise | ≤65dB |
Input AC | AC 380V ±15%/50/60±5Hz |
Efficiency Of Charge And Discharge | >85% |
Storage Environment Temperature | -20ºC~50ºC |
Protection Level | IP20 |
Number Of Channels | 4 |
Dimensions(W*D*H)(mm) | 600*800*1300(mm) |
Brand Name | Haida |
Model Number | HD-H213 |
Certification | CE,,ISO |
Place of Origin | China |
View Detail Information
Explore similar products
High Voltage And High Current Lithium Battery Test System For New Energy Battery
High Voltage Battery Pack Testing System 750V/2000V
PCB Battery Protection Board Testing System Power Battery Pack Protection Board
Finished / Semi-Finished Power Battery Testing System Battery Test Machine
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram | Supply Ability | 300 Sets per Month |
Delivery Time | 20 days after order confirmed | Packaging Details | each set protected with resin fiber and PP film, then put into Strong wooden case with operation man |
Output Power | 24kw | Input Current | 42.9A/Phase |
Noise | ≤65dB | Input AC | AC 380V ±15%/50/60±5Hz |
Efficiency Of Charge And Discharge | >85% | Storage Environment Temperature | -20ºC~50ºC |
Protection Level | IP20 | Number Of Channels | 4 |
Dimensions(W*D*H)(mm) | 600*800*1300(mm) | Brand Name | Haida |
Model Number | HD-H213 | Certification | CE,,ISO |
Place of Origin | China | ||
High Light | Battery Pack Module Charge Discharge Equipment ,EV Battery Life Cycle Testing Equipment |
Battery Pack Module Charge and Discharge EV Battery Life Cycle Testing System
Description:
Lithium batteries for electric vehicles
Lithium battery for electric bicycle
Energy storage lithium battery
Input AC | AC 380V ±15%/50/60±5Hz | ||||||||||
Output Power | 24 | KW | |||||||||
Input Current | 42.9 | A/Phase | |||||||||
Input Power | 28.2 | KW | |||||||||
Voltage | CV output range | 3~60V | |||||||||
Min discharge voltage | 3 | V | |||||||||
Accuracy | ±(0.02% of FS+0.02% of RD) | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Current | Output range/channel | 0.5A~100A | |||||||||
Accuracy | ±(0.05% of FS+0.05% of RD) | ||||||||||
CV cut-off current | 0.2A | ||||||||||
Stability | ± 0.1% of FS | ||||||||||
Power | Output power/channel | 6KW | |||||||||
Stability | ±0.2% of FS | ||||||||||
Time | Current response time | Max rising time: 5ms (10% to 90% or 90% to 10%) | |||||||||
Working step time | ≤(365*24)h/step, Time format-00:00:00.000(h,m,s,ms) | ||||||||||
Data record | Data record conditions | Min data record interval:10ms (connected with AUX channel:100ms) | |||||||||
Min voltage change:0.12V | |||||||||||
Min current change:0.2A | |||||||||||
Frequency | 100Hz (connected with AUX channel:10Hz) | ||||||||||
Charge | Charge mode | Constant current, Constant voltage, Constant current and voltage, Constant power | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity,-ΔV | ||||||||||
Discharge | Discharge mode | Constant current, Constant power, Constant resistance | |||||||||
Cut-off condition | Main channel:Voltage, Current, ΔTime, Capacity | ||||||||||
Pulse Mode | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Min pulse width | 100ms | ||||||||||
Pulse cycles | up to 32 | ||||||||||
Chg and Dischg switch | Supported | ||||||||||
Cut-off condition | Voltage, Time | ||||||||||
Simulation | Charge | Constant current, Constant power | |||||||||
Discharge | Constant current, Constant power | ||||||||||
Cut-off condition | Time,Line number | ||||||||||
Continuous switching Chg and Dischg | One simulation step can realize continuous switching from charging to discharging | ||||||||||
Limit step number | 1 million | ||||||||||
Cycle | Max cycles | 65535 | |||||||||
Max steps | 254 | ||||||||||
Cycle nest | 3 | ||||||||||
Protection | Power-off data protection | ||||||||||
Off-line operation mode | |||||||||||
User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc. | |||||||||||
Efficiency of Charge and discharge | >85% | ||||||||||
Protection level | IP20 | ||||||||||
Channels parallel | supported, Parallel channels do not support pulse and simulation testing | ||||||||||
Channels feature | Independent pairs of closed loop for constant | ||||||||||
Energy feedback | The discharge energy can be fed back to the grid | ||||||||||
Channels control mode | Independent control | ||||||||||
Noise | ≤65dB | ||||||||||
Database | MySQL | ||||||||||
Communicatin | TCP/IP | ||||||||||
Data export | EXCEL,TXT,CSV,PDF,Plot/Graph | ||||||||||
Disk drive | 500GB | ||||||||||
Operating system | Windows 7/8/10 64 bit | ||||||||||
Communication port | Ethernet port, CAN communication supports communication with BMS to obtain cell voltage and temperature in BMS | ||||||||||
Items | Values | ||||||||||
Number of channels | 4 | ||||||||||
Dimensions(W*D*H)(mm) | W*D*H:600*800*1300(mm) | ||||||||||
Working Environment requirement | |||||||||||
Items | Values | ||||||||||
Operation environment temperature | -10ºC~45ºC(When the temperature is 25±10ºC, the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /ºC) | ||||||||||
Storage environment temperature | -20ºC~50ºC | ||||||||||
Operation environment humidity | ≤70% RH(no moisture condensation) | ||||||||||
Storage environment humidity | ≤80% RH(no moisture condensation) |
Other models (Voltage and Current) | |||||
60V20A | 60V30A | 60V50A | 60V60A | 60V100A | 60V120A |
60V400A | 60V240A | 120V50A | 120V100A | 120V200A | 120V400A |
200V50A | 500V100A | 200V200A | 400V200A | 750V500A | 800V600A |
Machine equips Charge and Discharge Port or Discharge voltage below 0V is Optional |
Details
Why choose us?
1.Design & Production : Solution Consultation for each order
Recommend the most cost -performance machine
Research & Develop the suitable one for Special- designed Model.
2.Shipping & Delivery: One-Stop Service
Production- Deliver to your door - Installation & Training- Technical Support
3.Warranty
1 year warranty with lifetime technology support
4.After-Sale Service
React within 2 Hours
Video inspection & on-site service combined
FAQ
Q: How about your warranty?
Q: What is the order process?
Q: Can we visit your factory before order?
Q: Do you accept customization service?
Description:
BMS battery management testing system is used for parameter calibration, verification, and testing during the developm
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2004
Total Annual:
$ 5 Million-US$ 10 Million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr... Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr...
Get in touch with us
Leave a Message, we will call you back quickly!