Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
Supply Ability | 75 Piece / Pieces Per Month |
Delivery Time | 15 Days After Order |
Packaging Details | Strong Wooden Case |
Usage | Constant Temperature and Humidity Testing Machine |
Temp. range | -70°C~150°C |
Humid. range | 10~ 98 percent R.H. |
Resolution | 0.01°C, 0.1 percent, P.I.D control |
Heating up | -40°C ~ +100°C within 45 min |
Interior material | Stainless steel plate(SUS304) |
Insulation | Rigid foam |
Power | AC220V±10 percent 50/60Hz |
Use | temperature humidity testing chamber |
Brand Name | Haida |
Model Number | HD-E702 |
Certification | CE,,ISO |
Place of Origin | China |
View Detail Information
Explore similar products
Environmental Temperature Humidity Test Chamber With Climatic Simulation
Programmable Temperature And Humidity Test Chamber LCD Display P.I.D control
Laboratory Incubator Temperature Humidity Chamber Programmable
Centrifugal Air Circulation Chamber LCD Display Temperature Humidity
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram | Supply Ability | 75 Piece / Pieces Per Month |
Delivery Time | 15 Days After Order | Packaging Details | Strong Wooden Case |
Usage | Constant Temperature and Humidity Testing Machine | Temp. range | -70°C~150°C |
Humid. range | 10~ 98 percent R.H. | Resolution | 0.01°C, 0.1 percent, P.I.D control |
Heating up | -40°C ~ +100°C within 45 min | Interior material | Stainless steel plate(SUS304) |
Insulation | Rigid foam | Power | AC220V±10 percent 50/60Hz |
Use | temperature humidity testing chamber | Brand Name | Haida |
Model Number | HD-E702 | Certification | CE,,ISO |
Place of Origin | China | ||
High Light | Temperature And Humidity Controlled Cabinets ,Constant Temperature And Humidity Chamber |
Professional Stability High Low Temperature And Humidity Test Chamber
Temperature and humidity chamber.pdf
1. Performance of Stability High Low Temperature and Humidity Test Machine:
Get a performance evaluation to help provide the suitable chambers to you.
For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.
Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.
Questions for Performance Evolution Request:
System & Performance Options
Professional Stability High Low Temperature And Humidity Test Chamber is suitable materials, electrical and electronic products, household appliances, auto parts, chemical coatings, humidity chamber at the same time for a variety of electronic components and other related product components stored at high temperature, low temperature environment, transport, use of adaptation test, assess its performance.
Uses:
Electrical, instrumentation, chemical, biological / pharmaceutical products such as high temperature, performance testing, Humidity Chamber low temperature environment is the product development process for high-temperature environment testing or
2. Specifications of Stability High Low Temperature and Humidity Test Machine:
Range – 70 to 150°C
Temp/Humidity | HD-E702-100-7 | HD-E702-150-7 | HD-E702-225-7 | |
| HD-E702-408-7 | HD-E702-800-7 | HD-E702-1000-7 | |
Temp-only | HD-E702-100T-7 | HD-E702-150T-7 | HD-E702-225T-7 | |
| HD-E702-408T-7 | HD-E702-800T-7 | HD-E702-1000T-7 | |
Temperature Range: | -70°C ~150°C | |||
Cooling Capacity | ~ 2.5 kW at -50°C | ~ 3 kW at -50°C | ~ 5 kW at -50°C | |
~ 6.5 kW at-50°C | ~ 8.5 kW at -50°C | ~ 9 kW at - -50°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 | |
| 850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 | |
Exterior dimensions | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | |
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
Range – 40 to 150°C
Temp/Humidity | HD-E702-100-4 | HD-E702-150-4 | HD-E702-225-4 | |
| HD-E702-408-4 | HD-E702-800-4 | HD-E702-1000-4 | |
Temp-only | HD-E702-100T-4 | HD-E702-150T-4 | HD-E702-225T-4 | |
| HD-E702-408T-4 | HD-E702-800T-4 | HD-E702-1000T-4 | |
Temperature Range: | -40°C ~150°C | |||
Cooling Capacity | ~ 2 kW at -20°C | ~ 2.5 kW at -20°C | ~ 4.5 kW at -20°C | |
~ 5.5 kW at-20°C | ~ 8 kW at -20°C | ~ 8.5 kW at - -20°C | ||
Heating System | ~ 5 kW | ~ 5 kW | ~ 5.5 kW | |
~6.5 kW | ~ 8.5 kW | ~ 9 kW | ||
Temperature Fluctuation: | ±0.5°C | |||
Temperature Gradient: | ±0.5°C~±0.2°C | |||
Heating Rate†: | ≥3℃ / min average ( Advance model 5 – 15 ℃ / min) | |||
Cooling Rate†: | ≥1℃ / min average (Advance model 5 - 15℃ / min) | |||
Humidity Range: | 10%~95%RH (Ref to Normal Humidity Range Diagramed) | |||
Humidity Fluctuation: | ±1.5%RH~±2.0%RH | |||
Humidity Gradient: | ±3%RH | |||
Dimensions | ||||
Workspace dimensions | 500x400x500 HD-E702-100 | 600x500x500 HD-E702-150 | 750x500x600 HD-E702-225 | |
| 850x650x800 HD-E702-800 | 1000x1000x800 HD-E702-800 | 1000x1000x1000 HD-E702-1000 | |
Exterior dimensions | 1400x850x1050 | 1500x950x1050 | 1650x950x1150 | |
| 1750x1050x1350 | 1900x1450x1350 | 1900x1450x1550 | |
Site Requirements | ||||
Electrical Supply: | 208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific) | |||
Humidity Water | Distilled Water | |||
Condensate Drain: | 1/2" hose connection (gravity drain) |
Control System
Imported microcomputer temperature controller wet integrated controller (display directly percent humidity).
Accuracy range setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% R · H, indicating accuracy: temperature ± 0.1 ℃, temperature ± 0.1% R · H temperature and humidity sensors platinum platinum resistance · PT100Ω.
Heating system is completely independent system, electric heating nichrome heater.
Isolated external humidification systems, stainless steel boiler type shallow surface evaporative humidifier.
Circulatory system temperature low noise air conditioning motors, leafy centrifugal wind wheel.
Heating system
Far-infrared heating using nickel-chromium alloy heating wire heating speed;
High temperature, low temperature completely independent systems;
Temperature control P · I · D + S · S · R system with channel coordination control;
Temperature control the output power by the microcomputer calculus, to achieve high accuracy and high efficiency power efficiency.
Cooling System
Refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption of the exhaust gas temperature, after the temperature of the refrigerant through the condenser and other places in and around medium heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. Finally, the refrigerant passes through the evaporator isothermal heat from high temperature object, the object to be cooled so that the temperature is lowered. This loop again and again to achieve the purpose of cooling.
Standard Features:
Energy-saving Design:
In addition to fully consider the safety of refrigeration units, efficient use of all sectors, but while taking multiple energy saving measures: such as: adjusting the cooling capacity of the refrigeration system, liquid-gas bypass regulation, evaporation temperature regulation, low temperature at any point when the thermostat without heat balance, operating power can be reduced to half, so that operating costs and failure rates of the refrigeration system down to a more state of the economy.
Intelligent automatic transfer system expansion, the load automatically adjust the refrigerant flow + intelligent electric power data value (%) to match heating and cooling (load) Analog output data automatically according to the output value. This design than the traditional design saving more than 30%.
4. Professional Stability High Low Temperature and Humidity Test Machine view:
Maintain:
1. cabinets outside temperature and humidity chamber cleaning and maintenance
(1) temperature and humidity chamber at operation should be preceded by internal impurities removed.
(2) distribution room be cleaned at least once a year
Or more, can take advantage of a vacuum cleaner to clean indoor dust can be removed by suction.
(3) the outer casing shall be cleaned once a year or more, first with soap and water to wipe cleaning.
2. Check the temperature and humidity of the storage chamber humidifier humidifier maintenance within and should be replaced once a month to ensure clean water, humidification water dish should be cleaned every month to ensure smooth flow of water.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2004
Total Annual:
$ 5 Million-US$ 10 Million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr... Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr...
Get in touch with us
Leave a Message, we will call you back quickly!