Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram |
Supply Ability | 75 Piece / Pieces Per Month |
Delivery Time | 15 Days After Order |
Packaging Details | Strong Wooden Case |
Temp. fluctuation *2 | ±1.8°C |
Pre-heat upper limit | +200°C |
Temp. heat up time*3 | Ambient temp. to +200°C within 30min |
Pre-cool lower limit | -65°C |
Temp. pull down time*3 | Ambient temp. to -65°C within 70min |
External material | Cold-rolled rust-proofed steel plate |
Power supply | AC380V, 50/60Hz, three phase , 30A |
Cooling water supply pressure*6 | 02~0.4Mpa |
Brand Name | Haida |
Model Number | HD-E703 |
Certification | CE,,ISO |
Place of Origin | China |
View Detail Information
Explore similar products
Environmental High And Low Temperature Thermal Shock Test Chamber
Electronics Dust Resistance Aging Test Environmental Equipment
Temperature Cycling Altitude Environmental Test Chamber
ISO Certificated Professional High And Low Temperature Thermal Shock Environment
Product Specification
Payment Terms | L/C, T/T, D/A, D/P, Western Union, MoneyGram | Supply Ability | 75 Piece / Pieces Per Month |
Delivery Time | 15 Days After Order | Packaging Details | Strong Wooden Case |
Temp. fluctuation *2 | ±1.8°C | Pre-heat upper limit | +200°C |
Temp. heat up time*3 | Ambient temp. to +200°C within 30min | Pre-cool lower limit | -65°C |
Temp. pull down time*3 | Ambient temp. to -65°C within 70min | External material | Cold-rolled rust-proofed steel plate |
Power supply | AC380V, 50/60Hz, three phase , 30A | Cooling water supply pressure*6 | 02~0.4Mpa |
Brand Name | Haida | Model Number | HD-E703 |
Certification | CE,,ISO | Place of Origin | China |
High Light | environmental test chamber ,environmental lab testing equipment |
Evaporative Condenser Thermal BTC Tye Air Circulation Thermal Shock Chamber
Description:
Evaporative Condenser Thermal BTC Tye Air Circulation Thermal Shock Chamber is used to test or composite material structure, in an instant by the extremely high temperature and low temperature under continuous environment can endure degree, in order to in the shortest possible time to test its heat bilges cold shrink caused by chemical or physical damage
Meet The Standard:
GB/T2423.1 test method at low temperature;GB/T2423.2 high temperature test method;
GB/T2423.22 temperature test;GJB150.5 temperature impact test;
GJB360.7-87 temperature impact test;GJB367.2-87, 405 temperature impact test.
SJ/y73 T10187-91 series temperature test chamber SJ/y73 T10186-91 series temperature test chamber
IEC68-2-14 _ test method of GB/T2424.13 N_ temperature changes - 2002 test method for temperature change test guideline
GB/T2423.22-2002 temperature weathering test QC/T17-92 auto parts general rules
EIA364-32 thermal shock test program (temperature cycle) electric connector and socket of the environmental impact assessment
The Refrigeration System
refrigeration systems and compressors: To ensure the chamber cooling rate and minimum temperature requirements, the test chamber using binary cascade freon refrigeration system of a German COPELANDBAN composed of semi-hermetic compressors. Cascade refrigeration cycle system includes a high pressure and a low pressure refrigeration cycle, which is connected to the container evaporation condenser, evaporator and condenser will function as a low pressure circulation evaporator as a condenser of the high pressure circulation with.
Design and Application of refrigeration system energy regulation technology, an effective treatment can guarantee but also on energy and cooling capacity refrigeration systems can be adjusted in the case of the normal operation of the refrigeration unit, so that operating costs of the refrigeration system and failure down to a more state of the economy.
Refrigeration Works:
the level of the refrigeration cycle are used against the card if the cycle, which consists of two isothermal and two adiabatic processes, whose process is as follows: a refrigerant through the compressor adiabatic compression to a higher pressure, the power consumption the exhaust gas temperature after the refrigerant through the condenser isothermally in and around medium heat exchange medium heat to four weeks. After the refrigerant flows through the shutoff valve adiabatic expansion work, when the refrigerant temperature decreases. This loop again and again to achieve the purpose of cooling.
Specifications
System | Two-zone test by means of damper switching | |||||||
Three-zone chamber | ||||||||
Model | HD-E703-50A/HD-E703-50W | HD-E703-100A/HD-E703-100W | Customized | |||||
Performance | Test area | High temp. exposure range*1 | +60~ to +200°C | |||||
Low temp. exposure range*1 | -65to 0 °C | |||||||
Temp. fluctuation *2 | ±1.8°C | |||||||
Hot chamber | Pre-heat upper limit | +200°C | ||||||
Temp. heat up time*3 | Ambient temp. to +200°C within 30min | |||||||
Cold chamber | Pre-cool lower limit | -65°C | ||||||
Temp. pull down time*3 | Ambient temp. to -65°C within 70min | |||||||
Temp. recovery (2-zone) | Recovery conditions | Two-zone: High temp. exposure +125°C 30 min, Low temp. exposure -40°C 30 min; Specimen 6.5 kg (specimen basket 1.5kg) | ||||||
Temp. recovery time | Within 10 min. | |||||||
Construction | External material | Cold-rolled rust-proofed steel plate | ||||||
Test area material | SUS304 stainless steel | |||||||
Door*4 | Manually operated door with unlock button | |||||||
Heater | Strip wire heater | |||||||
Refrigeration unit | System*5 | Mechanical cascade refrigeration system | ||||||
Compressor | Hermetically sealed scroll compressor | |||||||
Expansion mechanism | Electronic expansion valve | |||||||
Refrigerant | High temp side:R404A, Low temp side R23 | |||||||
Cooler | Stainless steel welded plate heat exchanger | |||||||
Air circulator | Sirocco fan | |||||||
Damper driving unit | Air cylinder | |||||||
Fittings | Cable port with diameter 100mm on the left side (right side and tailor made diameter size are available as options), specimen power supply control terminal | |||||||
Inside dimensions (W x H x D) | 350 x 400 x 350 | 500 x 450 x 450 | Customized | |||||
Test area capacity | 50L | 100L | Customized | |||||
Test area load | 5 kg | 10 kg | Customized | |||||
Outside dimensions (W x H x D) | 1230 x 1830 x 1270 | 1380 x 1980 x 1370 | Customized | |||||
Weight | 800kg | 1100kg | N/A | |||||
Utility requirements
| Allowable ambient conditions | +5~30°C | ||||||
Power supply | AC380V, 50/60Hz, three phase , 30A | |||||||
Cooling water supply pressure*6 | 02~0.4Mpa | |||||||
Cooling water supply rate*6 | 8m³ /h | |||||||
Operating cooling water temp. range | +18 to 23 °C | |||||||
Noise Level | 70 dB or lower |
Notes
1. If the high-temp exposure range lower limit + 60°C is required or the low temp exposure range lower limit -60°C, please select the “ambient-temperature exposure” option
2. If the temp fluctuation need to below ±1.8°C please select the “Low temp fluctuation package”
3. Temperature heat-up/pull down time are applicable only during independent chamber operation
4. If the automatically operated sliding door required, please select the “Automatically door package”
5. Air-cooled condenser / Water-cooled condenser both available
6. Apply on water-cooled condenser only
Company Details
Business Type:
Manufacturer,Seller
Year Established:
2004
Total Annual:
$ 5 Million-US$ 10 Million
Employee Number:
200~300
Ecer Certification:
Verified Supplier
Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr... Haida International Equipment Co., Ltd Company Profile Haida established in 2004 in Dongguan City, where is the “silicon valley” of world manufacturing industry. It is a certified national high-tech enterprise engaged in design, research and development, production, sales, calibr...
Get in touch with us
Leave a Message, we will call you back quickly!