Payment Terms | L/C, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 10 unit / month |
Packaging Details | plywood case |
SKYLINE | Cleveland Open Cup Flash Point Tester |
Standard | ASTM D92 |
Working power supply | AC (220 ± 10%) V, 50Hz |
Temperature measurement range | room temperature~400 ℃; Temperature display unit 0.1 ℃ |
Repeatability | ≤ 8 ℃ (flash point and fire point) |
Reproducibility | ≤ 17 ℃ (flash point), ≤ 14 ℃ (fire point) |
Heating rate | in accordance with GB/T3536-2008 standard |
Ignition mode | gas flame, electronic ignition, optional |
Ambient temperature | (10~40) ℃ |
Relative humidity | ≤ 80% |
Power consumption of the whole machine | no more than 500W |
Boundary dimension | (when the lifting arm is not lifted) 520mm × 360㎜ × 310 ㎜ (long × wide × High); (When the lifting arm is lifted) 520mm × 360㎜ × 420 ㎜ (long × wide × High) |
Brand Name | SKYLINE |
Model Number | SL-OA09 |
Certification | CE , Calibration Certificate |
Place of Origin | CHINA |
View Detail Information
Explore similar products
ISO4406 Portable Particle Counter For Hydraulic And Lubricating Oil Analysis
SL-OA59 Copper Sheet Corrosion Tester LED Digital Display
ASTM D3828 Oil Analysis Testing Equipment Low Temp 8in Screen Closed Cup Flash
Automatic oil dielectric loss and volume resistivity tester
Product Specification
Payment Terms | L/C, D/P, T/T, Western Union, MoneyGram | Supply Ability | 10 unit / month |
Packaging Details | plywood case | SKYLINE | Cleveland Open Cup Flash Point Tester |
Standard | ASTM D92 | Working power supply | AC (220 ± 10%) V, 50Hz |
Temperature measurement range | room temperature~400 ℃; Temperature display unit 0.1 ℃ | Repeatability | ≤ 8 ℃ (flash point and fire point) |
Reproducibility | ≤ 17 ℃ (flash point), ≤ 14 ℃ (fire point) | Heating rate | in accordance with GB/T3536-2008 standard |
Ignition mode | gas flame, electronic ignition, optional | Ambient temperature | (10~40) ℃ |
Relative humidity | ≤ 80% | Power consumption of the whole machine | no more than 500W |
Boundary dimension | (when the lifting arm is not lifted) 520mm × 360㎜ × 310 ㎜ (long × wide × High); (When the lifting arm is lifted) 520mm × 360㎜ × 420 ㎜ (long × wide × High) | Brand Name | SKYLINE |
Model Number | SL-OA09 | Certification | CE , Calibration Certificate |
Place of Origin | CHINA | ||
High Light | oil analysis lab equipment ,oil analysis equipment |
The fully automatic open flash point tester is designed and manufactured in accordance with the requirements specified in the People's Republic of China standard GB/T3536-2008 Determination of Flash Point and Ignition Point of Petroleum Products Cleveland Open Cup Method. It is applicable to the determination of the flash point and ignition point of petroleum products other than fuel oil, whose open cup flash point is higher than 79 ℃ according to the method specified in this standard.
This instrument is a fully automatic open flash point tester, which is an ideal substitute for similar imported instruments. It can be widely used in railway, aviation, electric power, oil industry and scientific research departments.
1. It adopts 8-inch true color LCD, touch screen and Chinese man-machine dialogue interface. It has prompt menu and guided input mode for expected flash point, sample label, atmospheric pressure, test date and other parameters.
2. The function curve of temperature rise and test time is simulated and tracked, with Chinese misoperation software prompt modification function, test date, test time and other parameters prompt function.
3. Equipped with a standard 232 interface or USB interface to connect with the computer to automatically upload data. It can be connected to the LIMIS system.
4. 120 groups of data can be stored, which can be connected with the computer to store data in large capacity and for a long time.
5. Automatically correct the influence of atmospheric pressure on the test and calculate the correction value.
6. Differential detection, automatic correction of system deviation.
7. The data scanning, detection and printing are completed automatically, and the test arm is raised and lowered automatically.
8. Automatic air cooling
Working power supply | AC (220 ± 10%) V, 50Hz |
Temperature measurement range | room temperature~400 ℃;Temperature display unit0.1 ℃ |
Repeatability | ≤ 8 ℃ (flash point and fire point) |
Reproducibility | ≤ 17 ℃ (flash point), ≤ 14 ℃ (fire point) |
Heating rate | in accordance with GB/T3536-2008 standard |
Ignition mode | gas flame, electronic ignition, optional |
Ambient temperature | (10~40) ℃ |
Relative humidity | ≤ 80% |
Power consumption of the whole machine | no more than 500W |
Boundary dimension | (when the lifting arm is not lifted) 520mm × 360㎜ × 310 ㎜ (long × wide × High); (When the lifting arm is lifted) 520mm × 360㎜ × 420 ㎜ (long × wide × High) |
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Importer,Exporter,Seller
Year Established:
2011
Total Annual:
120000-350000
Employee Number:
100~107
Ecer Certification:
Verified Supplier
SKYLINE (DONGGUAN SKYLINE INDUSTRIAL CO.,LTD) provides full line of Toys Testing Equipment, Fire Testing Equipment ,Flammability Testing Equipment,Tensile Test Machine, Furniture Testing Machines ,Textile Testing Equipment and other lab test equipment .We also offers value added support service... SKYLINE (DONGGUAN SKYLINE INDUSTRIAL CO.,LTD) provides full line of Toys Testing Equipment, Fire Testing Equipment ,Flammability Testing Equipment,Tensile Test Machine, Furniture Testing Machines ,Textile Testing Equipment and other lab test equipment .We also offers value added support service...
Get in touch with us
Leave a Message, we will call you back quickly!