China factories

China factory - Labnovation Technologies, Inc.

Labnovation Technologies, Inc.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Universal Dengue Antigen And Antibody Test Kit Immunochromatography
China Universal Dengue Antigen And Antibody Test Kit Immunochromatography

  1. China Universal Dengue Antigen And Antibody Test Kit Immunochromatography
  2. China Universal Dengue Antigen And Antibody Test Kit Immunochromatography

Universal Dengue Antigen And Antibody Test Kit Immunochromatography

  1. MOQ: 10000/Pcs
  2. Price: US$1.0-1.3/pcs
  3. Get Latest Price
Payment Terms D/A, D/P, T/T
Supply Ability 500000/Day
Delivery Time 5-7 work day
Packaging Details Carton
Shele Life 24 Months
Total Accuracy >95%
Humidity ≤60%,
Group Universal
Storage Condition Store 2-30℃
Test Speed Within 15 minutes
Brand Name LABNOVATION
Model Number LQ-000101
Certification ISO13485, ISO9001,
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms D/A, D/P, T/T Supply Ability 500000/Day
Delivery Time 5-7 work day Packaging Details Carton
Shele Life 24 Months Total Accuracy >95%
Humidity ≤60%, Group Universal
Storage Condition Store 2-30℃ Test Speed Within 15 minutes
Brand Name LABNOVATION Model Number LQ-000101
Certification ISO13485, ISO9001, Place of Origin China
High Light Universal dengue antigen and antibody testISO dengue antigen and antibody testImmunochromatography dengue ns1 rapid test kit

Rapid Test Kit Dengue Antigen And AntibodY Rapid Test Kit NS1/IgG/IgM Antigen And Antibody Combo Test Kit


Intenden Use
Dengue NS1 Antigen & IgG/IgM Antibody Rapid Test Kit is a rapid Immunochromatography for the qualitative detection of antibodies (IgM and IgG) and dengue virus NS1 antigen to dengue virus in serum/plasma/whole blood to aid in the diagnosis of Dengue viral infection.
Specifications

Name Dengue NS1 Antigen & IgM/IgG Antibody Rapid Test Kit
No LQ-000101
Sample Type Serum, Plasma, Whole Blood
Sample Volume NS1:3 Drops(80-100μ), IgG/IgM:1 Drop(30μl)
Package Size 25 Tests/Kit
Product Shelf Life 24 Months
Test Speed Within 15 minutes
Storage Condition Store 2-30℃


 
Main Components

  • 25 Test Cassettes
  • 25 Disposable Pipettes
  • 1 Specimen Buffer
  • 1 Instruction Manual

Material Needed But Not Provided

  • Specimen Collection Containers
  • Centrifuge (for serum/plasma sample)
  • Timer

Product Features

  • Rapid testing for antigen within 15 minutes
  • Facilitates patient treatment decisions quickly
  • Simple step to test with easy interpretation
  • Shorter test period with higher performance
  • Excellent sensitivity and quality

Advantage

  • Simple Operation:

Do not require additional instruments to process the test and read the result.

  • Quick Check:

Easy to use in simple step,15 minutes out of results.

  • Clear Result:

The detection board is divided into two lines, the result is clear and easy to read.

Notic 

Instructions must be read entirely before taking the test. Allow the test device controls to equilibrate to room temperature for 30 minutes (20℃-30℃) prior to testing. Do not open the inner packaging until ready, it must be used in one hour if opened (Humidity≤60%, Temp: 20℃-30℃). Please use immediately when the humidity>60%.

Use Step

  • Take off the outer packing, put the panel onto the desk with the sample window up.
  • NS1: Drop 3 drops (80-100μl) of serum/plasma/whole blood vertically into the sample well of NS1. If the whole blood sample is thick, add about 1 drop (40-50μl) of specimen buffer into the sample well of NS1
  • IgG/IgM: Drop 1 drop (30μl) of serum/plasma/whole blood vertically into the sample well of IgG/IgM, add about 2 drops (80-100μl) of specimen buffer into the sample well of IgG/IgM.
  • Observe the test results immediately within 15-20 minutes, the result is invalid after 20 minutes.

Analytical Resualts

Item IgG IgM NS1
Specificity 98.46% 98.44% 99.02%
Sensitivity 96.19% 95.37% 97.92%
Accuracy 97.67% 97.33% 98.67%

Interpreation Of Result
 

  • For Dengue NS1:
  1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and the other line should be in the test region (T).
  2. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (T).
  3. INVALID: No red lines appear or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.
  • For Dengue IgG/IgM:

  1. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgG test region (G), indicating the Dengue IgG positive.
  2. POSITIVE: Two distinct red lines appear. One line should be in the control region (C) and another line should be in the IgM test region (M), indicating the Dengue IgM positive.
  3. POSITIVE: Three distinct red lines appear in the control region (C), the IgG test region (G) and the IgM test region (M), indicating the Dengue IgG and Dengue IgM positive.
  4. NEGATIVE: One red line appears in the control region(C). No apparent red or pink line appears in the test region (G and M).
  5. INVALID: No red bands appear or control line fails to appear, indicating that the operator error or reagent failure. 


Storage And Expiry

Store as packaged in the sealed pouch at 2-30℃, avoid hot and sunshine, dry place, valid for 24 months. DO NOT FREEZE. Some protective measures should be taken in hot summer and cold winter to avoid high temperature or freeze-thaw.

Other Informations

  • The results of the reagent are only for clinical reference, which is not the only basis for clinical diagnosis and treatment.
  • A confirmed diagnosis and treatment should only be made by a physician after all clinical and laboratory findings have been evaluated.
  • Cannot be used for screening the general population, but can only be used for the screening of patients with clinical symptoms or when there is suspicious exposure.
  • The continued existed or not existed of antibodies cannot be used to determine if the treatment is succeeded or not.

FAQ

  • MOQ?

MOQ is 10000 pcs

  • Shippment?

We choose Air cargo or Ocean cargo.

  • Delivery date?

It will depend on your order quantities. We will confirm with you after you placed the order.

  • Payment Method?

Business to business account.

  • Do you support OEM/ODM order?

Of couse, we support OEM/ODM order.

  • Are you a manufacturer or trading company?

We are manufacturer.

  • After-sales Service

Any questions or needs you can contact us online / by e-mail, ect. we will get back to you within 24 hours.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement