LD-100 POCT HbA1c Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Which is a semi-automatic instrument used to analyze glycated hemoglobin and it's suitable for the detection of HbA1c in medical units at all levels.
Specifications
Model
LD-100
Method
Boronate Affinity
Operating Type
1-Step, fully automatic
Measurement Time
Less than 3 minutes
Sample Type
Whole blood
Sample Volume
4ul
Measurement Range
HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l)
Data storage
7000
Operating Condition
Temperature:15~35℃ Humidity:15~80%R.H
Storage Condition
Analyzer:10-60℃; Test kit: 2~8℃
Voltage
12VDC-3.33A
Device category
Fixed
PRINCIPLE
Uses the (borate affinity) fluorescent immunoturbidimetry
Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
The percentage of glycosylated hemoglobin in total hemoglobin can be determined.
Feature
One-step Operation, simple use process easy to test HbA1c
Protable, easy to carry
Fast tets speed, Real-time detection
Battery Integrated
Portable, Compact
Cv<3%, Excellent Correlation With HPLC
RFID For Batch Management
Color touch screen
External printer (Blue-tooth)
USB Port
LIS Support
Reliable
IFCC calibrator
Normal
Abnormal
Normal
Abnormal
Mean HbA1c%
5.4
9.6
5.3
9.2
CV (%)
2.5%
1.9%
2.4%
1.8%
Use Step
Place cartridge in analyzer
Push bead into reagents
Insert sample into cartridge
Performance Parameters
Accuracy:The accuracy is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
Result reporting unit:Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
Precision:Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
Appearance:The appearance of the instrument is neat and clean, and there is no obvious peeling, abrasion, disbonded coating and dirt on the surface coating; The nameplate and logo should be clear. All fasteners should not be loosened. Various adjusting elements can rotate flexibly and function normally. Readouts should be clear on the display screen.
Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
Functions of the analyzer:The function of report output in English; Abnormal alarm function.
Permission: The authority is the first-level authority, and the login authority is the first-level authority
Certificated
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer
Year Established:
2001
Total Annual:
10000000-50000000
Employee Number:
100~600
Ecer Certification:
Active Member
Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...