China factories

China factory - Labnovation Technologies, Inc.

Labnovation Technologies, Inc.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type
China Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type

  1. China Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type

Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type

  1. MOQ: 1
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms D/A, D/P, T/T
Supply Ability 100/Day
Delivery Time 15-20 working days
Packaging Details Carton
Name POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test
Sample Type Whole blood
Test Time ≤2 Minutes
Sample Volume 4μL
Test Range 4%-15%
Shelf life of test kit 9 Months
Brand Name LABNOVATION
Model Number LD-100
Certification IFCC, NGSP, CE
Place of Origin Shenzhen, China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms D/A, D/P, T/T Supply Ability 100/Day
Delivery Time 15-20 working days Packaging Details Carton
Name POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test Sample Type Whole blood
Test Time ≤2 Minutes Sample Volume 4μL
Test Range 4%-15% Shelf life of test kit 9 Months
Brand Name LABNOVATION Model Number LD-100
Certification IFCC, NGSP, CE Place of Origin Shenzhen, China
High Light POCT HbA1c Analyzer 2 minutesBoronate Affinity POCT HbA1c Analyzer

POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test​

 

POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test is intended for detecting  glycoslated hemoglobin (HbA1c) in human blood.

 

According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021.

 


Specification

 

Model LD-100
Method Boronate Affinity
Measurement Time ≤2 minutes
Sample Type Whole blood
Measurement Range 4.0-15%
Sample Volume 4μL
Shelf life of test kit 9 months
Weight ≤800g
Dimensions 192(L)*128(W)*108(H)mm
 

 


Principle

 

The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.

 

 

 

 

The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.

 

After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence

After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.

After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.

Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.

 

 

 


Feature

 

Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).


 

 


Certificate

 

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement