Payment Terms | D/A, D/P, T/T |
Supply Ability | 100 Units/Day |
Delivery Time | 5-7 work day |
Packaging Details | Carton |
Method | HPLC |
Test Speed | 90 seconds/test |
Sample Type | Whole Blood, Pre-diluted blood |
Column Capacity | 3000 Test |
Dimensions | 378*380*510mm |
Certificated | NGSP,IFCC |
Data Storage | 5000 Test |
Precision | CV<2% |
Brand Name | LABNOVATION |
Model Number | LD-560 |
Certification | IFCC, NGSP, CE |
Place of Origin | Shenzhen, China |
View Detail Information
Explore similar products
HbA1c Analyzer Fully Automated HbA1c Analyzer LD-600 (HPLC)
Human Blood Smart Auto Hematology Analyzer 9027809990
Whole Blood Prediluted Blood HbA1c Test Analyzer Hematology Instruments
90 Second 420nm HbA1c Test Analyzer Full Modular Hematology Equipment
Product Specification
Payment Terms | D/A, D/P, T/T | Supply Ability | 100 Units/Day |
Delivery Time | 5-7 work day | Packaging Details | Carton |
Method | HPLC | Test Speed | 90 seconds/test |
Sample Type | Whole Blood, Pre-diluted blood | Column Capacity | 3000 Test |
Dimensions | 378*380*510mm | Certificated | NGSP,IFCC |
Data Storage | 5000 Test | Precision | CV<2% |
Brand Name | LABNOVATION | Model Number | LD-560 |
Certification | IFCC, NGSP, CE | Place of Origin | Shenzhen, China |
Labnovaion Analyzer LD-560 For HbA1c Testing CV<2% HPLC Method IFCC Certificated HbA1c Analyzer
Intended Use
LD-560 is a fully Automated HbA1c Analyzer which is used in conjunction with suitable reagents for the quantitative detection of glycosylated hemoglobin (HbA1c) in human blood.
Specification
Model | LD-560 |
Method | HPLC |
Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
Test Speed | 90 seconds per test |
Reagents kit | Eluent A, Eluent B, Hemolysis |
Autoloader Capacity | 20 tubes |
Precision | CV<2% |
Dimension | 378(L) ×380(W)×510(H)mm |
Weight | 28kg |
Operation Preparation
Before operating this analyzer, please read the operation manual carefully to avoid malfunction or damage.
If the analyzer is used in a manner not specified by the manufacturer, the protection provided by the analyzer may be destroyed.
Before turning on the analyzer, the operator must check the following requirements to ensure that the system is ready.
(1) Check the remaining amount of reagents
Check whether the remaining amount of eluent A, eluent B, eluent C and hemolysis agent is sufficient.
(2) Check the waste liquid barrel
Check whether the waste liquid barrel has been emptied before starting the analyzer every day.
(3) Check the liquid tubes and power supply
Check whether the tubes of reagent and waste liquid are bent and whether the connections are reliable.
Check the analyzer for fluid leakage.
Check whether the power plug of the analyzer is securely inserted into the power socket.
(4) Check the printer
Check whether the paper roll is sufficient and whether it is installed in correct place.
Certificate
FAQ
A: Yes , we have. The display is a minicap computer.
A: Yes, we have. LD-560 install the built-in printer.
A: Yes. The instrument has been tested by safety regulations and EMC to meet regulatory requirements.
A: Ring injection, 20 sample positions.
Company Details
Business Type:
Manufacturer
Year Established:
2001
Total Annual:
10000000-50000000
Employee Number:
100~600
Ecer Certification:
Active Member
Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...
Get in touch with us
Leave a Message, we will call you back quickly!