China factories

China factory - Labnovation Technologies, Inc.

Labnovation Technologies, Inc.

  • China,Shenzhen
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Portable Hospital Saliva Antigen Test Kit SARS-CoV-2 Rapid Test Machine
China Portable Hospital Saliva Antigen Test Kit SARS-CoV-2 Rapid Test Machine

  1. China Portable Hospital Saliva Antigen Test Kit SARS-CoV-2 Rapid Test Machine
  2. China Portable Hospital Saliva Antigen Test Kit SARS-CoV-2 Rapid Test Machine

Portable Hospital Saliva Antigen Test Kit SARS-CoV-2 Rapid Test Machine

  1. MOQ: 10000 Pieces
  2. Price: Negotiation
  3. Get Latest Price
Payment Terms T/T, D/A, D/P
Supply Ability 500000/Day
Delivery Time 5-7 work day
Packaging Details Carton
Total Accuracy 98.02%
Specimen Saliva
Test Time <15 min
Quanlity Guarantee Period 18 months
Storage Condition 2℃-30℃
Application Hospital, Medical Center, School, Lab, etc
Brand Name LABNOVATION
Model Number LX-401603
Certification ISO13485,ISO9001,CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, D/A, D/P Supply Ability 500000/Day
Delivery Time 5-7 work day Packaging Details Carton
Total Accuracy 98.02% Specimen Saliva
Test Time <15 min Quanlity Guarantee Period 18 months
Storage Condition 2℃-30℃ Application Hospital, Medical Center, School, Lab, etc
Brand Name LABNOVATION Model Number LX-401603
Certification ISO13485,ISO9001,CE Place of Origin China
High Light Hospital Saliva Antigen Test Kit94.29% Saliva Antigen Test KitMSDS SARS CoV 2 Rapid Test Machine

Rapid Tets Kit Antigen Rapid Test SARS-CoV-2 Antigen Saliva Rapid Test Kit

Intend Use

The rapid test kit is intended for the qualitative detection of SARS-CoV-2 antigen in hunman saliva samples from novel coronavirus suspected person with symptoms within 9 days from onset.

 
Product Details

Item Value
Model Number LX-401603
Type 20 Test
Warranty 18 Months
Quality Certification CE, MSDS
Safty Standard ISO13485
Sample volume 3 Full drops
specificity 99.00%
sensitivity 94.29%
Storage Temperature 2℃-30℃

 
Product  Feature

  • Fast: Quick test speed, you can read the result within 15 minutes
  • Accurate: High accuracy, specificity and sensitivity, accuracy rate more than 95%
  • Protable:  Easy to collect sample, you can do the test anywhere, anytime
  • Simple: Easy to operate, one step testing process

Test Principle

  • Immunochromatography assay.
  • Gold immunochromatographic test principle, double antibody sandwich method was used to detect SARS-CoV-2 nucleocapsid antigen in the samples.
  • There is virus antigen presence in the sample, the antigen binds with the corresponding colloidal gold monoclonal antibody and the coated monoclonal antibody at the detection line to form a compound and then condenses into a red band, indicating a positive result.
  • There is no antigen in the sample, complex cannot be formed at the detection line, and no red band is shown, indicating negative result.
  • Notic: Whether the sample contains antigen or not, the gold monoclonal antibody will bind to the enveloped antibody at the quality control line, form a compound and condense into a red band.

  • Main Components
  • Test Cassettes
  • Saliva Collectors With Collection Tubes 
  • Sample Extraction Buffers
  • Tube stand
  • Package Insert


 
Use Step

  • Open the cap of the collection tube and istall saliva collector.
  • Put the collection tube with saliva collector close to lips and let the saliva flow into the collection tube. Tje volum of saliva needs to be half of 0.5 scal mark(0.25).
  • Screw the sample extraction buffer carefully.

  • Add all sample extration buffer to the collection tube. Discard the saliva collector, tighten the cap onto the specimen collection tube.
  • Shake the specimen collection tube at least three time vigorously to mix the saliva and the extraction buffer. Squeeze bottom of the collection tube ensure the saliva is thoroughly mixed.
  • Add 3 full drops of the solution to the sample well(S). Read the result at 15 minutes. Do not interpret the result after 20 minutes.

 
Result Interpretation

  • POSITIVE: Two (2) distinct colored lines appear. One line should be in the control region (C) and the other line should be in the test region (T).

  • NEGATIVE: One (1) colored line appears in the control region(C). No apparent colored line appears in the test region (T). The negative result does not indicate the absence of analytes in the sample, it only indicates the level of tested analytes in the sample is less than the minimum detection limit.

  • INVALID: No colored lines appear, or control line fails to appear, indicating that the operator error or reagent failure. Verify the test procedure and repeat the test with a new testing device.

 
 
Virus Sources

Global high frequency mutation Alpha / B.1.1.7(U.K.) Beta I B.1.351(South Africa)
Gemma I P.1(Brazil) Kappa I B.1.617.1(India) Delta I B.1.617.2(India)
C.37,ect Alpha I B.1.17(U.K.) B.1.36.16.etc
A.2.5,etc A.23.1 Alpha I B.1.17(U.K.)
B.1.1.33.etc C.1.1.etc.  

 
Certificate

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer

  • Year Established:

    2001

  • Total Annual:

    10000000-50000000

  • Employee Number:

    100~600

  • Ecer Certification:

    Active Member

Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent... Labnovation Technologies, Inc. is an original manufacturer established in Shenzhen, China since 2001. We are dedicated in developing and manufacturing IVD instruments and reagents including HbA1c analyzer and reagents, rapid test reader & reagents, hematology reagents, clinical chemistry reagent...

+ Read More

Get in touch with us

  • Reach Us
  • Labnovation Technologies, Inc.
  • 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
  • https://www.labnovationtest.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement