Payment Terms | T/T,Western Union,MoneyGram |
Delivery Time | 5-8 work days |
Sensitivity (mV/A) | 100 |
Current (KA) | 0.06 |
Maximum noise (mV Vpp) | 4 |
Low frequency bandwidth -3dB(Hz) | 67 |
High frequency bandwidth -3dB(MHz) | 30 |
Insulation voltage value | 1KV |
Maximum output voltage | 6Vpk |
Terminal load | ≥100kΩ |
Brand Name | MEASTEK |
Model Number | HCTS0060A |
View Detail Information
Explore similar products
MDP4070B High Voltage Differential Probes,700V Range,100MHz Bandwidth Floating
MEASTEK MDP4070C High Voltage Differential Probe 700V 200MHz Electronics Test
MEASTEK MDP4150B 100MHz High Voltage Differential Probe, ±1500V Ultra High
MEASTEK MDP4150C High Voltage Differential Probe 200MHz Bandwidth, 500X
Product Specification
Payment Terms | T/T,Western Union,MoneyGram | Delivery Time | 5-8 work days |
Sensitivity (mV/A) | 100 | Current (KA) | 0.06 |
Maximum noise (mV Vpp) | 4 | Low frequency bandwidth -3dB(Hz) | 67 |
High frequency bandwidth -3dB(MHz) | 30 | Insulation voltage value | 1KV |
Maximum output voltage | 6Vpk | Terminal load | ≥100kΩ |
Brand Name | MEASTEK | Model Number | HCTS0060A |
High Light | Power Bus Monitoring Flexible Current Probe ,30MHz Flexible Current Probe ,0.06KA Flexible Current Probe |
HCTS0060A 100mV/A High Frequency Flexible Current Probe 30MHz Bandwidth , 0.06KA Peak Current For Power Bus Monitoring
Precise current measurement
Sensitivity 100mV/A, typical accuracy 2%, can accurately measure current, effectively measure the harmonic composition in the current, and provide reliable data for circuit analysis.
Excellent high-frequency response
The high-frequency bandwidth of 30MHz can accurately detect high-frequency sinusoidal current waveforms, and has obvious advantages in high-frequency scenarios such as semiconductor switch current measurement.
Adapt to small package devices
The small and soft induction loop has an outer diameter of 1.6mm (1.7mm Max) and a withstand voltage of 1KVpk, which is an ideal choice for current measurement of small package devices, such as IGBT and MOSFET pin current measurement.
Low insertion loss
The insertion loss is extremely low, only a few picohenries, and there is almost no interference to the circuit under test. The standard BNC interface is convenient for connecting various measurement devices.
Flexible power supply and operation
It adopts USB 5V power supply and is simple to operate. Follow safety precautions when using, such as checking the probe ring, staying away from interference sources, etc., to ensure accurate measurement.
Specifications
Model | HCTS0060A | |
Sensitivity (mV/A) | 100 | |
Peak | Current (KA) | 0.06 |
dI/dt(KA/μs) | 4 | |
Maximum noise (mV Vpp) | 20 | |
Attenuation characteristics(%/ms) | 65 | |
Low frequency bandwidth -3dB(Hz) | 67 | |
High frequency bandwidth -3dB(MHz) | 30 | |
Typical accuracy | 2% | |
Insulation voltage value | 1KV |
HCT(S)XXXXA Series Other Technical Parameters
Maximum output voltage | 6Vpk | |
Terminal load | ≥100kΩ | |
Power supply mode | USB 5V (standard adapter) | |
Operating temperature range | Integrator | 0℃ - 50℃ |
Probe ring | 0℃ - 100℃ | |
Storage temperature range | -40℃~80℃ |
Product Description
(Take HCTS0120A as an example)
1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)
4) Test connection diagram.
Mechanical specifications
Model | HCTSXXXXA |
Typical value of flexible probe circumference (customizable) | 80mm |
Typical value of induction ring body diameter | 1.6mm |
Typical value of flexible probe diameter (customizable) | 25mm |
Induction loop connection cable length | 1 M (customizable) |
BNC connection cable length | 1 M or 2 M, 1 M is Standard |
Integrator body dimensions (including BN port dimensions) | About 110(L)*47(W)*30(H)mm |
USB cable (AM-BM) | About 1.8m |
USB output adapter | About 59mm*30mm*20mm |
Probe weight | About 150g |
Box weight (including probe) | About 960g |
Care And Maintenance
1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.
Packing List
Name | Quantity |
Current probe integrator | 1 piece |
Current probe flexible induction coil | 1 piece |
USB output adapter (5V/1A) | 1 piece |
USB power cable | 1 piece |
BNC output cable | 1 piece |
Electronic manual | 1 serving |
Company Details
Business Type:
Manufacturer
Ecer Certification:
Verified Supplier
Shenzhen Knowhow Technology Co., Ltd. is a high-tech enterprise focusing on the research, development, production and sales of Fume Extractor equipment and industrial Smoke Extractors. The company was founded in Shenzhen, China and is committed to providing efficient and environmentally friend... Shenzhen Knowhow Technology Co., Ltd. is a high-tech enterprise focusing on the research, development, production and sales of Fume Extractor equipment and industrial Smoke Extractors. The company was founded in Shenzhen, China and is committed to providing efficient and environmentally friend...
Get in touch with us
Leave a Message, we will call you back quickly!