Payment Terms | T/T,Western Union,MoneyGram |
Delivery Time | 5-8 work days |
Sensitivity (mV/A) | 50 |
Current (KA) | 0.12 |
Maximum noise (mV Vpp) | 3 |
Attenuation characteristics (%/ms) | 70 |
Low frequency bandwidth -3dB(Hz) | 80 |
High frequency bandwidth -3dB(MHz) | 10 |
Typical accuracy | 1% |
Insulation voltage value | 10KV |
Brand Name | MEASTEK |
Model Number | HCTL0120A |
View Detail Information
Explore similar products
MDP4070B High Voltage Differential Probes,700V Range,100MHz Bandwidth Floating
MEASTEK MDP4070C High Voltage Differential Probe 700V 200MHz Electronics Test
MEASTEK MDP4150B 100MHz High Voltage Differential Probe, ±1500V Ultra High
MEASTEK MDP4150C High Voltage Differential Probe 200MHz Bandwidth, 500X
Product Specification
Payment Terms | T/T,Western Union,MoneyGram | Delivery Time | 5-8 work days |
Sensitivity (mV/A) | 50 | Current (KA) | 0.12 |
Maximum noise (mV Vpp) | 3 | Attenuation characteristics (%/ms) | 70 |
Low frequency bandwidth -3dB(Hz) | 80 | High frequency bandwidth -3dB(MHz) | 10 |
Typical accuracy | 1% | Insulation voltage value | 10KV |
Brand Name | MEASTEK | Model Number | HCTL0120A |
High Light | High-frequency Flexible Current Probe ,Power Bus Monitoring Current Probe ,10KV Insulation Current Probe |
MEASTEK HCTL0120A High-frequency Flexible Current Probe - 10KV Insulation High-voltage And High-current Test For Power Bus Monitoring
High-frequency flexible design, bandwidth up to 10MHz, can accurately detect high-frequency sinusoidal current waveforms, meet the needs of high-frequency current measurement, and perform well in semiconductor switch current measurement scenarios.
50mV/A high sensitivity, with 1% typical accuracy, can accurately measure 50/60Hz tiny currents, is a high-quality choice for high-precision current probes, and is often used for capacitor ripple current measurement.
10KV insulation voltage value, safe and reliable, suitable for power bus monitoring under high-voltage environment, in line with the search trend of high-voltage current measurement equipment.
The outer diameter of the probe ring is 8mm, and the induction ring is soft and can shuttle through narrow spaces, easily dealing with complex wiring in distributed current monitoring scenarios.
USB power supply, easy to use, with a standard BNC output interface, convenient to connect to oscilloscopes and other equipment, to meet data acquisition and current waveform observation needs.
Specifications
Model | HCTL0120A | |
Sensitivity (mV/A) | 50 | |
Peak | Current (KA) | 0.12 |
dI/dt(KA/μs) | 0.8 | |
Maximum noise (mV Vpp) | 3 | |
Attenuation characteristics(%/ms) | 70 | |
Low frequency bandwidth -3dB(Hz) | 80 | |
High frequency bandwidth -3dB(MHz) | 10 | |
Typical accuracy | 1% | |
Insulation voltage value | 10KV |
HCT(S)XXXXA Series Other Technical Parameters
Maximum output voltage | 6Vpk | |
Terminal load | ≥100kΩ | |
Power supply mode | USB 5V (standard adapter) | |
Operating temperature range | Integrator | 0℃ - 50℃ |
Probe ring | 0℃ - 100℃ | |
Storage temperature range | -40℃~80℃ |
Product Description
(Take HCTS0120A as an example)
1) Input interface: current probe test signal input terminal.
2) Output interface: current probe integrator signal output terminal.
3) USB 5V power supply interface: standard USB (type B) interface. (USB power supply cable and power adapter are standard)
4) Test connection diagram.
Mechanical specifications
Model | HCTSXXXXA |
Typical value of flexible probe circumference (customizable) | 80mm |
Typical value of induction ring body diameter | 1.6mm |
Typical value of flexible probe diameter (customizable) | 25mm |
Induction loop connection cable length | 1 M (customizable) |
BNC connection cable length | 1 M or 2 M, 1 M is Standard |
Integrator body dimensions (including BN port dimensions) | About 110(L)*47(W)*30(H)mm |
USB cable (AM-BM) | About 1.8m |
USB output adapter | About 59mm*30mm*20mm |
Probe weight | About 150g |
Box weight (including probe) | About 960g |
Care And Maintenance
1) Keep the probe clean and dry.
2) If cleaning is required, wipe with a soft dry cloth. Do not use chemical cleaning agents.
3) When the probe is not in use, please put it in the packaging provided and place it in a cool, clean and dry place.
4) When transporting the probe, be sure to put it in the packaging provided by our company to prevent shock.
5) Do not pull the input and output lines hard to avoid excessive twisting, bending or knotting.
Packing List
Name | Quantity |
Current probe integrator | 1 piece |
Current probe flexible induction coil | 1 piece |
USB output adapter (5V/1A) | 1 piece |
USB power cable | 1 piece |
BNC output cable | 1 piece |
Electronic manual | 1 serving |
Company Details
Business Type:
Manufacturer
Ecer Certification:
Verified Supplier
Shenzhen Knowhow Technology Co., Ltd. is a high-tech enterprise focusing on the research, development, production and sales of Fume Extractor equipment and industrial Smoke Extractors. The company was founded in Shenzhen, China and is committed to providing efficient and environmentally friend... Shenzhen Knowhow Technology Co., Ltd. is a high-tech enterprise focusing on the research, development, production and sales of Fume Extractor equipment and industrial Smoke Extractors. The company was founded in Shenzhen, China and is committed to providing efficient and environmentally friend...
Get in touch with us
Leave a Message, we will call you back quickly!