Payment Terms | T/T in advance, L/C |
Supply Ability | 50 sets/month |
Delivery Time | 15 working days |
Brand Name | KINGSINE |
Model Number | K3163i |
Certification | ISO9001, CE |
Place of Origin | China |
View Detail Information
Explore similar products
High Precision KFA310 Mini Protection Relay Tester Multi-Functional
K3063i GOOSE Message Analysis Relay Protection Tester Show GOOSE Control Block
K3166i Protective Relay Tester / Protection Relay Test Equipment
High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040
Product Specification
Payment Terms | T/T in advance, L/C | Supply Ability | 50 sets/month |
Delivery Time | 15 working days | Brand Name | KINGSINE |
Model Number | K3163i | Certification | ISO9001, CE |
Place of Origin | China | ||
High Light | Universal Protection Relay Testing Complying IEC61850 ,GOOSE Protection Relay Testing |
◆ Digital signal complying IEC61850-9-1 / IEC61850-9-2 protocols.
◆ Synchronize with GPS,IRIG-B.
◆ Suitable testing for all kinds of electromagnetic relays,microcomputer relays.
Model | Current Outputs | Voltage Outputs | ||||
K3166i | 6×35A@450VA max / 3×70A@850VA max | 7×310V@90VA max | ||||
K3163i | 6×35A@450VA max / 3×70A@850VA max | 4×310V@124VA max | ||||
K3130i | 3×35A@450VA max | 4×310V@124VA max |
1. Two 100Mbit Optical Fiber ports for SMV and GOOSE simulations(exchangeable with RJ45).
2. 6×35A & 4×310V independent high burden output channels.
3. 13 channels independent low-level signal outputs.
4. AC/DC measurement(8 channels inputs,class 0.05,0-600V/0-5A,auto range).
5. Transducer calibartion (class 0.02).
6. Energy meter calibration(Mechanical & Electronic meters).
7. Transient play back up to 3KHZ.
8. Light weight <18kg.
9.Fully function KRT software testing modules.
10.3-Years guarantee of free repair and life-long maintenance.
11.Free software upgrade.
Testing Items | ANSI® No. | |||||
IEC61850 numerical IEDs relay & merge unit | -- | |||||
Distance protection relay | 21 | |||||
Synchronising or synchronism-check relays | 25 | |||||
Undervoltage relays | 27 | |||||
Directional Power relays | 32 | |||||
Undercurrent or underpower relays | 37 | |||||
Negative sequence overcurrent relays | 46 | |||||
Overcurrent/ground fault relays | 50 | |||||
Inverse time overcurrent/ground fault relays | 51 | |||||
Power factor relays | 55 | |||||
Overvoltage relays | 59 | |||||
Voltage or current balance relays | 60 | |||||
Directional overcurrent relays | 67 | |||||
Directional ground fault relays | 67N | |||||
DC overcurrent relays | 76 | |||||
Phase-angle measuring or out-of-step protection relays | 78 | |||||
Automatic reclosing devices | 79 | |||||
Frequency relays | 81 | |||||
Motor overload protection relays | 86 | |||||
Differential protection relays | 87 | |||||
Directional voltage relays | 91 | |||||
Voltage and power directional relays | 92 | |||||
Tripping relays | 94 | |||||
Voltage regulating relays | -- | |||||
Overimpedance relays, Z> | -- | |||||
Underimpedance relays, Z | -- | |||||
Time-delay relays | -- |
1. 10 Channels (6×35A & 4×310V) outputs, each output channels are independent and simultaneous
control of magnitude, phase angle and frequency values, able to inject DC, AC sine wave and up
to 20 × harmonics.
2. Variable battery simulator, DC 0-350V, 140Watts max.
3. 13 Low-level channels outputs up to 8Vac/10Vdc max.
4. 0-600V / 0-5A AC/DC measurement in 0.05 class.
5. Graphical test modules and templates for testing of various relays.
6. Quick relay testing facility in Manual mode.
7. Shot/Search/Check, Point & Click testing.
8. RIO/XRIO import & export facility.
9. Switch on to fault test(SOTF).
10.Power system model for dynamic testing.
11.Inbuilt GPS and IRIG-B sync end-to-end testing.
12.Online Vector display.
13.Automatic test results assume.
14.Automatic test report creation.
15.Anti-clipping detect,wrong wiring connect alarm and self-protect, overload and overheat protection.
Voltage Outputs | ||||||
Output Range & Power | 4×310V ac (L-N) | 124VA max each | ||||
2×620V ac (L-L) | 248VA max each | |||||
3×350V dc (L-N) | 140W max each | |||||
Accuracy | AC:<0.03%Rd + 0.02Rg Typ. / <0.07%Rd + 0.03Rg Guar. | |||||
DC: ±10mV @<5V,±0.5% @ ≥5V | ||||||
Resolution | 1mV | |||||
Distortion | <0.05% Typ. / <0.1% Guar. | |||||
Current Outputs | ||||||
Output Range & Power | 6×35A ac(L-N) | 450VA max single | ||||
3×70A ac(2L-N) | 850VA max single | |||||
1×100A ac(6L-N) | 1200VA max | |||||
3×20A dc(L-N) | 300W max each | |||||
Accuracy | AC:<0.03%Rd + 0.02Rg Typ. / <0.15%Rd + 0.05Rg Guar. | |||||
DC: ±5mA @<1A,±0.5% @ ≥1A | ||||||
Resolution | 1mA | |||||
Distortion | <0.05%Typ. / <0.1% Guar. | |||||
Low-Level Output | ||||||
Quantity | 13 Channels, 16 pin aviation socket | |||||
Voltage outputs range | AC 0-8V, DC 0-10V | |||||
Current outputs range | Nominal 2mA, 10mA max transient | |||||
Output Power | ≥0.5VA | |||||
Accuracy | (0.01~0.8 Vrms):<0.05% Typ. / <0.1% Guar. | |||||
(0.8~8 Vrms):<0.02% Typ. / <0.05% Guar. | ||||||
Resolution | 0.25mV | |||||
Distortion(THD%) | <0.05%Typ. / <0.1% Guar. | |||||
Frequency & Phase Angle | ||||||
Frequency Range | DC~1KHZ, 3KHZ transient | |||||
Frequency Accuracy | ±0.5ppm | |||||
Frequency Resolution | 0.001Hz | |||||
Phase Range | 0°~360° | |||||
Phase Accuracy | <0.05°Typ. / <0.1° Guar. 50/60Hz | |||||
Phase Resolution | 0.001° | |||||
IEC61850 Fiber & GOOSE Ethernet Ports (Optional Function) | ||||||
Fiber Ports | 2×100 Base-FX Full Duplex, LC type
(Optional to 10/100Mbit, Ethernet RJ45 type) | |||||
Fiber Type | 62.5/125um (Multiple optical fiber, Orange Red) | |||||
Wavelength | 1310nm | |||||
Transmit Distance | >1Km | |||||
Indicator | Spd Green (light): Valid connection
| |||||
Note: Hardware is ready, to be actived. | ||||||
Aux. DC Voltage Source(Battery simulator) | ||||||
Range | 0~350V @ 180W max | |||||
Accuracy | 0.5%Rg Guar. | |||||
Binary Input | ||||||
Quantity | 8 pairs | |||||
Type | wet/dry, measurement | |||||
Threshold | 10~600Vdc or potential free, Programmable | |||||
Time resolution | 100us | |||||
Debounce time | 0~25ms (Software Controlled) | |||||
Time range | Infinite | |||||
Time errors | ±1ms @ 0.001~1s, ±0.1% @>1s | |||||
Galvanic isolation | 4 isolated with each 2 pairs | |||||
Binary Output (Relay Type) | ||||||
Quantity | 4pairs | |||||
Type | Potential free relay contacts,software controlled | |||||
Break Capacity AC | Vmax: 400Vac / Imax:8A / Pmax:2500VA | |||||
Break Capacity DC | Vmax: 300Vdc / Imax:5A / Pmax:150W | |||||
Binary Output (Semiconductor Type) | ||||||
Quantity | 4pairs | |||||
Type | Open-collector, 14 pin Aviation socket | |||||
Break Capacity DC | 5~15Vdc / 5mA, 10mA max
| |||||
Response time | 100us | |||||
Synchronization | ||||||
Synchronization Mode | GPS, SMA type antenna connector / IRIG-B / IEEE1588 | |||||
Power supply & Environment | ||||||
Nominal Input Voltage | 100~240Vac | |||||
Permissible Input Voltage | 85~264Vac, 125~350VDC | |||||
Nominal Frequency | 50/60Hz | |||||
Permissible Frequency | 45Hz~65Hz | |||||
Power Consumption | 1500 VA max | |||||
Connection Type | Standard AC socket 60320 | |||||
Operating Temperature | -10℃~55℃ | |||||
Storage Temperature | -20℃~70℃ | |||||
Humidity | <95%RH, non-condensing | |||||
Others | ||||||
PC Connection | RJ45 Ethernet, 10/100M | |||||
Grounding Terminal | 4mm banana socket | |||||
Weight | 18Kg | |||||
Dimensions(W×D×H) | 468×375×164(mm) |
DC Measurement Input(Transducer calibrator) * Hardware is ready,to be actived. | ||||||
Voltage input | Range | 0~±10V dc | ||||
Max Input | ±11V dc | |||||
Accuracy | <0.02% rg Typ. / <0.05% rg Guar. | |||||
Input Impedance | 1M ohm | |||||
Current Input | Range | 0~±1mA / 1~20mA, auto range | ||||
Max Input | 600mA | |||||
Accuracy | <0.02% rg Typ. / <0.05% rg Guar. | |||||
Input Impedance | 15 ohm | |||||
AC / DC Measurement Input( Standard meter ) * Require extra PCB installed in factory only | ||||||
Input Quantity | 8 channels (blend with binary input pairs) | |||||
Voltage rang | 0~600Vrms (Rg: 0.1V,1V,10V,60V,600V) | |||||
Voltage accuracy | <0.05% Rg | |||||
Current range | Shunt input: 0~5Arms / 0~30Arms (Optional) | |||||
Current accuracy | <0.1% Rg | |||||
Sample rate | 10KHz | |||||
Input impedance | 600KΩ | |||||
Frequency range | 45~65Hz, Accuracy<0.01Hz | |||||
Phase accuracy | 0~360°,<0.2° Typ. | |||||
| ||||||
Energy Meter Calibration * Hardware is ready,to be actived | ||||||
Sensor Usage | Mechanical meters / Electronic meters | |||||
Sensor Output | High level : >4.5V, Low level: <0.2V | |||||
Pulse Input | 1 pulse input port | |||||
Pulse Range | 500KHz pulse input Max. | |||||
Pulse Output | 1 Transistor output, Open-collector, 5-15Vdc/5mA |
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!