Payment Terms | L/C,T/T |
Supply Ability | 100 sets/month |
Delivery Time | 15 working days |
Voltage Range | 0~300V |
Voltage Accuracy | ±0.1% |
Size (W x H x D) | 360 x 140 x 325mm |
Weight | <8 kg (without accessories) |
Operating Temperature | -10°C up to + 55°C |
Humidity | Relative humidity 5% up to 95% not condensing |
Brand Name | Kingsine |
Model Number | KT210 |
Certification | CE/ISO9001 |
Place of Origin | China |
View Detail Information
Explore similar products
CT / PT Analyzer
CT Transformer Measurement
KT210 TFT LCD Display Portable Automatic CT PT Analyzer
KT210 CT/PT Analyzer
Product Specification
Payment Terms | L/C,T/T | Supply Ability | 100 sets/month |
Delivery Time | 15 working days | Voltage Range | 0~300V |
Voltage Accuracy | ±0.1% | Size (W x H x D) | 360 x 140 x 325mm |
Weight | <8 kg (without accessories) | Operating Temperature | -10°C up to + 55°C |
Humidity | Relative humidity 5% up to 95% not condensing | Brand Name | Kingsine |
Model Number | KT210 | Certification | CE/ISO9001 |
Place of Origin | China | ||
High Light | IEC 60044-1 CT Analyzer ,IEC 61869-2 CT Analyzer ,IEC 60044-1 Current Transformer Test Set |
Current Transformer Test Set IEC60044-1 CT Analyzer KT210
Description Of Current Transformer Analyzer
Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard.
Feature Of Current Transformer Test Set
● | High measurement accuracy, resistance accuracy is 0.1%+1mΩ, phase accuracy±0.05 degree, variable accuracy is ±0.1% (1-5000 ), variable accuracy is ±0.2%(5000-10000). |
● | It can test current transformer according to IEC60044-1, IEC60044-6, IEC61869-2 and ANSI30/45 standard etc. |
● | Complete measurement function, it can test all type current transformer for secondary overload, secondary loop resistance, excitation characteristic, transient characteristic, ratio difference, angle difference and polarity. It can also test exact limit coefficient(ALF), device security coefficient(FS), secondary time constant(Ts), remanence coefficient(Kr), transient area coefficient(Ktd), inflexion voltage, current, level, saturation inductance, un-saturation inductance, 5% 10% error curve, of current transformer, hysteresis loop for current transformer, and evaluate test result according to defined standard. |
● | PT Test As for those inductive PT based on the definition of GB1207-2006(IEC60044-2), KT210 CT/PT Analyzer can also test them. KT210 CT/PT Analyzer can do variable ratio, polarity and secondary winding excitation test of inductive PT. |
Specification Of Current Transformer Test Device
Voltage Measurement Input | |
Secondary Input Range | 0~300V |
Max Knee point | 30KV |
Secondary Input Accuracy | ±0.1% |
Primary Input Range | 0~30V |
Primary Input Accuracy | ±0.1% |
Output | |
Output Voltage | 0 Vac to 120 Vac |
Output Current | 0 A to 5 A (15 A peak) |
Output Power | 0 VA to 450 VA (1500 VA peak) |
Main Power Supply | |
Input Voltage | 176 Vac to 264 Vac @ 10A Max |
Permissible Input Voltage | 120 Vdc to 370 Vdc @ 5A Max |
Frequency | 50 / 60 Hz |
Permissible Frequency | 47 Hz to 63 Hz |
Connection | Standard AC socket 60320 |
Physical Dimensions | |
Size (W x H x D) | 360 x 140 x 325mm |
Weight | <8 kg (without accessories) |
Environment Conditions | |
Operating Temperature | -10°C up to + 55°C |
Storage Temperature | -25°C up to + 70°C |
Humidity | Relative humidity 5% up to 95% not condensing |
Advantage Of Current Transformer Test System
Easy to operate CT / PT Analyzer,
120V / 15A Current Output,
9.7 inch touch screen operation,
IEC60044-1, IEC60044-6, IEC61869-2, ANSI30/45 standard
High stability for bushing CT testing;
FAQ
Q: Can the device test the function of Synchronising or synchronism-check relays?
A: Yes.
Q: How about the guarantee of repair?
A: All of our products have 3-years guarantee of free repair, and life-long maintenance.
Q: What is your technical advantages?
A: Easy to operate, measure quickly, all test can be done automatically based on the same connection line type except overload impedance measurement.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!