Delivery Time | 15 working days |
Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month |
Place of Origin | China |
Brand Name | Kingsine |
Certification | ISO9001,CE |
Model Number | KS813 |
View Detail Information
Explore similar products
High Precision Energy Meter Calibration Equipment 220VAC / 50Hz
Easy To Operation AC Power Calibrator , 50Hz / RS232 KS803
High Accuracy Power Meter Calibrator 25VA Voltage / RS232 Port
Electrical Power Calibrator with 100V / 300V , RS232 KS823
Product Specification
Delivery Time | 15 working days | Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month | Place of Origin | China |
Brand Name | Kingsine | Certification | ISO9001,CE |
Model Number | KS813 | ||
High Light | RS232 Connector Electricity Meter Calibration ,power meter calibrator KS813 |
Power Calibrator With RS232 Connector KS813
Current (AC) Output Shift:100mA/1A/5A/10A/25A Auto switch
Voltage (AC) Output Shift:10V/30V/100V/300V/750V Auto switch
Work power supply range:220VAC±15%, 50Hz
PC connection:RS232
Large LCD display, English pop-up menus in operations!
Features &Function
1. Capable of calibrating all kinds of indicating instruments such as DC meters, AC meters, phase meters, frequency meters, power meters, power factor meters, multimeters, energy meters and electric measurement transducers, etc. Automatic calibration mode and manual calibration mode are built-in of KS833.
2. These built-ins are high precision standard sources that respectively relate to voltage, current, phase, power factor and harmonic.Capable of outputting standard voltage, current, phase, active power, cross-phase reactive power and true reactice power, make use of software to realize closed loop control on all outputs guaranteeing its low drift and its annual stability. Current generator provides the function of open-circuit protection and open-circuit alert in itself. While voltage generator possesses the function of short-circuit protection.
3. Can freely output 2-31 times harmonics, including: Standard output at Grade 0.1 for 2nd-19th harmonics, and satandard output of Grade 0.2 for 20th-31st harmonics.
4. Large LCD display, all English pop-up menus for these operations:①rotary encoder operation ② slight-touch keyboard operation ③operation under PC Windows System.
5. Built-in RS232 port, allows software upgrade without opening up the external box of the equipment; and calibrated data can be uploaded into PC computer at users’ convenience.
6. The shock and impact resistance external box is made of high intensity aluminum alloy. Inside are reliable high-power heating radiator units, and the equipment is durable to use.
Technical Data of KS813
Voltage (AC) Output/Measure |
|
Shift |
10V/30V/100V/300V/750V Auto switch |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG (RG abbr. range) |
Stability |
0.01%/1min |
Voltage (DC) Output/Measure |
|
Shift |
100mV/1V/10V/30V/100V/300V/750V |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG (RG abbr. range) |
Stability |
0.01%/1min |
Current (AC) Output/Measure |
|
Shift |
100mA/1A/5A/10A/25A Auto switch |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG |
Stability |
0.01%/1min |
Current (DC) Output/Measure |
|
Shift |
1mA/10mA/100mA/1A/5A/10A/25A Auto switch |
Adjusting range |
0 ... 120% |
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG |
Stability |
0.01%/1min |
Power Output/Measure |
|
Min Adjusting Unit |
Shift x 0.01% |
Resolution |
Shift x 0.01% |
Accuracy |
0.05%RG (PF≥0.5) |
Stability |
0.01%/1min |
Frequency Output/Measure |
|
Range |
45.000...65.000Hz |
Min Adjusting Unit |
0.001Hz |
Accuracy |
0.01%RD |
Phase Output/Measure |
|
Range |
0.00° ... 359.99° |
Min Adjusting Unit |
0.01° |
Resolution |
0.01° |
Accuracy |
0.05° |
Power factor Output/Measure |
|
Output range |
-1 ... 0 ... +1 |
Min Adjusting Unit |
0.0001 |
Accuracy |
0.0005 |
Harmonic Output/Measure |
|
Set range |
2 ... 31 times |
Content |
Voltage, Current≤30%( compared with Fundamental Wave) |
Harmonic output accuracy |
0.1%(2 ... 19 times, compared with Fundamental Wave) |
Resolution |
0.2%(20 ... 31 times, compared with Fundamental Wave) |
Harmonic Phase |
0.00° ... 359.99° |
Output Voltage and Current distortion |
|
<0.2%(non capacitance load) |
|
Max AC Output Load |
|
Voltage 25VA, Current 25VA |
|
Index measure reference condition |
|
Environment temperature |
22±1 °C |
Work temperature |
0°C ... 40°C |
Humidity range |
≤85 % |
Work power supply range |
220VAC±15%, 50Hz |
Weight |
24KG |
Dimensions |
450(D)×180 (W)×380 (H) mm |
PC connection |
RS232 |
Major functions:
|
KS803 |
KS813 |
KS823 |
KS833 |
AC Standard Sources |
● |
● |
● |
● |
DC Standard Sources |
○ |
● |
● |
● |
Harmonic Standard Sources |
● |
● |
● |
● |
Indicator Test |
○ |
○ |
● |
● |
Transmitter Test |
○ |
○ |
○ |
● |
Energy Meter Test |
○ |
○ |
○ |
● |
Note: Without the corresponding function modules.
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!