Product Specification
Delivery Time | 15 working days | Payment Terms | T/T in advance ,L/C |
Supply Ability | 5000PCS/Month | Place of Origin | China |
Brand Name | Kingsine | Model Number | PMC100 |
Certification | ISO9001,CE | ||
High Light | PMC100 Multifunctional Power Meter ,Single Phase Multifunctional Power Meter ,2 Channel PMC100 Multifunctional Power Meter |
Single Phase Multifunctional Power Meter , 2-Channel PMC100
Single phase electric parameter measurment and energy metering
On-line monitoring of electric parameter limit alarm, relay relevance alarm output
Support 2 channel DI/DO, can configure transducer output
Support MODBUS-RTU, RS485 communication
Overview
PMC100 series single phase digital power meter adopts customized, modularized, high brightness LED display, very beautiful and grand; use low-power microprocessor as core, to achieve all-electric parameter measurement and energy metering. Can optional configure various binary, relay, analog output interface to achieve user’s various needs; integrates RS-485 communication ports, can easily fulfill the integration of various intelligent distribution System. The product function is practical, easy to use and maintenance. Can be used in on-site equipment monitoring and control , provide measure support for electric application experts, provide data basis for SCADA and Smart Grid, provide decision-making basis for effective intelligent energy management.
Function Features
Function Features | PMC100Z | PMC100C | PMC100P | PMC100F | PMC100U | PMC100I | PMC100N |
Instantaneous real virtual value |
|
|
|
|
|
|
|
Current | ◆ |
| ◆ |
|
| ◆ | ◆ |
Voltage | ◆ |
| ◆ |
| ◆ |
| ◆ |
Frequency | ◆ |
|
| ◆ |
|
| ◆ |
Active power | ◆ |
| ◆ |
|
|
| ◆ |
Reactive power | ◆ |
|
|
|
|
| ◆ |
Power factor | ◆ | ◆ |
|
|
|
| ◆ |
Energy |
|
|
|
|
|
|
|
Active energy | ◆ |
|
|
|
|
| ◆ |
Communication |
|
|
|
|
|
|
|
RS485 /MODBUS protocol | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Display |
|
|
|
|
|
|
|
LED display | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
Other |
|
|
|
|
|
|
|
2-channel DI | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
2-channel DO | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
1 channel AO :4-20mA | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
|
2-channel limits alarm | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Support program online upgrade | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ | ◆ |
Technical Parameter
Electrical Characteristics | ||
Measurement Type | Single phase AC system | |
| Sampling rate per cycle: 64 times | |
Data refresh rate | 1S | |
Measurement Accuracy
| Current | 0.2% |
Voltage | 0.2% | |
Power | 0.5% | |
Frequency | 0.05Hz | |
Active Energy | 1.0% | |
AO | 1% | |
Input voltage characteristics | Measuring voltage | 0~600 V (Direct Access) |
Allowed overload | 1.2 times / continuous | |
Input impedance | 1.8MΩ | |
Input current characteristic | Measuring current | 5A or 1A (Via CT Connect) |
Allowed overload | 1.2 times / continuous | |
Input impedance | <0.1Ω | |
Binary INPUT | Working voltage | 12~24 VDC (external power supply) |
Input impedance | 12KΩ | |
Isolation voltage | 2KV | |
Relay output | Node Type | Mechanical shock |
Node capacity | 220 VAC/5A, 30 VDC/5A | |
4-20mA DC Output | Open circuit voltage | 5VDC |
Overload capacity | ≤200Ω | |
Isolation voltage | 2KV | |
Working power supply | AC | 85~265 VAC/45-65Hz |
DC | 100~300 VDC | |
Power dissipation | <2.5W | |
Mechanical properties | ||
Weight | 0.3kg | |
IP protection grade | panel IP52, body IP30 | |
Size | 96 X 48 X 72 mm | |
Operating temperature | -25~70℃ | |
Storage Temperature | -40~85℃ | |
Relative Humidity | 5% - 90%RH, No condensation | |
EMC | ||
Electrostatic discharge interference | IEC 61000-4-2, Level 4 | |
Group of anti-fast transient pulse | IEC 61000-4-4, Level 4 | |
Anti-impact | IEC 61000-4-5, Level 3 | |
Anti-frequency magnetic field | IEC 61000-4-8, Level 3 | |
Electrical insulation performance | ||
Insulation resistance | GB/T13729, >50MΩ | |
Frequency withstand voltage | GB/T13729, AC 2KV 50Hz /1min | |
Impulse voltage | GB/T13729, 5KV, 1.2/50us |
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!