Delivery Time | 15 working days |
Payment Terms | T/T in advance ,L/C |
Supply Ability | 5000PCS/Month |
Place of Origin | China |
Brand Name | Kingsine |
Certification | ISO9001,CE |
Model Number | PMC100N |
View Detail Information
Explore similar products
Engybrick Distributed Intelligent Power Monitoring Module
Single Phase Multifunctional Power Meter , 2 Channel PMC100
MODBUS-RTU Protocol , Multifunctional Power Meter , RS485 PMC100N
Digital Multifunctional Power Meter , Three-Phase PMC180
Product Specification
Delivery Time | 15 working days | Payment Terms | T/T in advance ,L/C |
Supply Ability | 5000PCS/Month | Place of Origin | China |
Brand Name | Kingsine | Certification | ISO9001,CE |
Model Number | PMC100N | ||
High Light | power quality in electrical systems ,portable power quality analyzer |
MODBUS-RTU Protocol Multifunctional Power Meter
single phase electric parameter measurment and energy metering
On-line monitoring of electric parameter limit alarm
Network meter without LCD operation panel, optional transducer function output
Support MODBUS-RTU, RS485 communication
Overview
PMC100N single phase network power meter is a multifunctional network meter without LCD operation panel. It adopts low power dissipation microprocessor, can measuring complete power parameter, energy measurement. It has RS-485 communication port and could be easily integrated to any intelligent power distribution system. PMC180N has the practical function, easy use, easy maintenance. It can use to monitor and control of the on-site equipment, supply the measuring & testing support to the power application specialist, supply the data base to the SCADA and Smart Grid, provide scientific basis for intelligent energy management.
Function Features
Function Features
|
PMC100Z |
PMC100C |
PMC100P |
PMC100F |
PMC100U |
PMC100I |
PMC100N |
Instantaneous real virtual value |
|
|
|
|
|
|
|
current |
◆ |
|
◆ |
|
|
◆ |
◆ |
voltage |
◆ |
|
◆ |
|
◆ |
|
◆ |
frequency |
◆ |
|
|
◆ |
|
|
◆ |
active power |
◆ |
|
◆ |
|
|
|
◆ |
reactive power |
◆ |
|
|
|
|
|
◆ |
power factor |
◆ |
◆ |
|
|
|
|
◆ |
Energy |
|
|
|
|
|
|
|
active energy |
◆ |
|
|
|
|
|
◆ |
Communication |
|
|
|
|
|
|
|
RS485 /MODBUS protocol |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
Display |
|
|
|
|
|
|
|
LED display |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
|
other |
|
|
|
|
|
|
|
2 channel DI |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
|
2 channel DO |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
|
1 channel AO :4-20mA |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
|
2 channel limits alarm |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
support program online upgrade |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
◆ |
Technical parameter
Electrical Characteristics |
||
Measurement Type
|
single phase AC system |
|
|
Sampling rate per cycle: 64 times |
|
Data refresh rate |
1S |
|
Measurement Accuracy
|
Current |
0.2% |
Voltage |
0.2% |
|
Power |
0.5% |
|
Frequency |
0.05Hz |
|
Active Energy |
1.0% |
|
Input voltage characteristics
|
Measuring voltage |
0~600 V (Direct Access) |
Allowed overload |
1.2 times / continuous
|
|
Input impedance |
1.8MΩ |
|
Input current characteristic |
Measuring current |
5A or 1A (Via CT Connect) |
Allowed overload |
1.2 times / continuous |
|
Input impedance |
<0.1Ω |
|
Binary input |
Working voltage |
12~24 VDC external power supply) |
Input impedance |
12KΩ |
|
Isolation voltage |
2KV |
|
Relay output |
Node Type
|
Mechanical shock |
Node capacity |
220 VAC/5A, 30 VDC/5A |
|
4-20mA AC input |
Open circuit voltage
|
5VDC |
overload capacity |
≤200Ω |
|
Isolation voltage |
2KV |
|
|
AC |
85~265 VAC/45-65Hz |
DC |
100~300 VDC |
|
Power dissipation |
< 2.5W |
|
Mechanical properties
|
||
Weight |
0.3kg |
|
IP protection grade |
IP52 |
|
Size |
75 X 55 X120 mm |
|
Operating temperature |
-25~70℃ |
|
Storage Temperature |
-40~85℃ |
|
Relative Humidity |
5% - 90%RH, No condensation |
|
EMC |
||
Electrostatic discharge interference |
IEC 61000-4-2, Level 4 |
|
Group of anti-fast transient pulse |
IEC 61000-4-4, Level 4 |
|
Anti-impact
|
IEC 61000-4-5, Level 3 |
|
Anti-frequency magnetic field |
IEC 61000-4-8, Level 3 |
|
Electrical insulation performance |
||
Insulation resistance |
GB/T13729, >50MΩ |
|
Frequency withstand voltage |
GB/T13729, AC 2KV 50Hz /1min |
|
Impulse voltage |
GB/T13729, 5KV, 1.2/50us |
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!