Delivery Time | 15 working days |
Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month |
Place of Origin | China |
Brand Name | Kingsine |
Certification | ISO9001,CE |
Model Number | K3040i |
View Detail Information
Explore similar products
High Precision KFA310 Mini Protection Relay Tester Multi-Functional
K3063i GOOSE Message Analysis Relay Protection Tester Show GOOSE Control Block
K3166i Protective Relay Tester / Protection Relay Test Equipment
High Fidelity Protection Relay Testing / 51 Overcurrent Relay K3040
Product Specification
Delivery Time | 15 working days | Payment Terms | T/T in advance ,L/C |
Supply Ability | 50 sets/ month | Place of Origin | China |
Brand Name | Kingsine | Certification | ISO9001,CE |
Model Number | K3040i | ||
High Light | protection relay testing training ,protective relay tester |
220V Protection Relay Testing
1. Easy test
2. Operation menu, Simple operation
3. Power:1000VA
1. Unique self-protection system assure the powerful protection when instrument is operating, automatic
stop the output when the network is abnormal ;
2. Unique power switch and amplifier technology, so the output precision and power efficiency and factor
are increased, which conforms to international tendency of energy save and environmental protection;
3. With alarm function of housing grounding testing and external voltage input, to guaranty personal
security;
4. Two in one of meter and source, with function of both internal and external testing, self-calibration,
oscillograph, and the duration of each oscillograph reaches 50S (optional function);
5. Offer independent Aux. DC to tested devices, 0 ~ 300V/0.6A (Poleless and adjustable);
6. Function of transducer and energy meter testing (optional function);
7. Testing interface offer unique output monitoring function and Pre-curve-tracing function, helps more on
the spot analysis;
Technical Data of K3040i
Voltage generators |
||
Setting Range |
4-phase AC (L-N) |
4 x 0 ... 300 V |
2-phase AC (L-L) |
2 x 0 ... 600 V |
|
Power |
4-phase AC (L-N) |
4 x 110VA, at 0 ... 300 V |
2-phase AC (L-L) |
2 x 220VA, at 0 ...600 V |
|
Accuracy |
<0.07% reading + 0.03% range guaranteed at 0 ... 300 V <0.02% reading + 0.01% range typical at 0-300V |
|
Resolution |
1mV |
|
Current generators |
||
Setting Range |
3-phase AC (L-N) |
3 x 0 ... 40 A |
1-phase AC (2L-N) |
1 x 0 ... 80 A |
|
1-phase AC (3L-N) |
1 x 0 ... 120 A |
|
Power |
3-phase AC (L-N) |
3x 450VA , at 0 ... 40A |
1-phase AC (2L-N) |
1x 520VA, at 0 ... 80A |
|
1-phase AC (3L-N) |
1 x 1200 VA, at 0 ... 120A (Max.) |
|
Accuracy |
<0.07% reading + 0.06% range guaranteed at 0-40A <0.02% reading + 0.02% range typical at 0-40A |
|
Resolution |
1mA |
|
Generators, general |
||
Frequency |
Range |
0 ... 1000 Hz |
Accuracy / drift |
Error < 0.001Hz at 10 ... 65Hz, Error < 0.01Hz at 65Hz...450Hz Error < 0.02Hz at 450Hz...1000Hz |
|
Resolution |
0.001Hz |
|
Phase |
Range |
- 360° ... +360° |
Accuracy / drift |
Error < 0.2 ° |
|
Resolution |
0.1° |
|
Timer |
Range |
Infinite |
Accuracy / drift |
Error<0.1ms |
|
DC generators |
||
Voltage ranges |
0 ... 300V/180W |
|
Current ranges |
0 ... 20A/300W |
|
Accuracy |
<0.07% reading + 0.03% range guaranteed at 0-300V <0.04% reading + 0.02% range typical at 0-300V |
|
<0.14% reading + 0.06% range guaranteed at 0-20A <0.05% reading + 0.02% range typical at 0-20A |
||
Resolution |
1mA; 1 mV |
|
Aux DC Supply |
||
Range |
0...300V/0.6A |
|
Binary inputs |
||
Number |
8 pairs |
|
Compatible Voltage |
10V ... 250V DC |
|
Binary outputs |
||
Number |
4 Pairs |
|
Capacity |
250V/3A AC/DC |
|
Synchronization |
||
Synchronization mode |
GPS |
|
Harmonic |
||
Harmonic overlap times |
2 ... 20 times |
|
Power supply |
||
Nominal input voltage |
220V AC±20% |
|
Power |
1000VA |
|
Nominal frequency |
47Hz….65Hz |
|
Environmental conditions |
||
Operation temperature |
-5°C ... 55 °C |
|
Storage temperature |
-20°C ... 75 °C |
|
Humidity range |
5% ... 90 %, non-condensing |
|
Weight |
20 KG |
|
Dimensions |
460(D)×140 (W)×360 (H) mm |
|
PC connection |
RJ45 |
K30 Series Protection Relay Test Set
Model |
Channels |
AC Outputs |
K3063i / K3063Li |
10 output channels |
6*30A/3*40A/4*300V |
K3030i / K3030Li |
7 output channels |
3*30A/4*300V |
K3066 |
13 output channels |
6*20A/3*40A/7*130V |
K3063 |
10 output channels |
6*20A/3*40A/4*130V |
K3040 |
7 output channels |
3*40A/4*130V |
K3030 |
7 output channels |
3*30A/4*130V |
Major Functions
Items |
IEEE(R) No. |
Synchronization relay |
|
Fault transplay |
|
GPS Synchronization |
|
Overcurrent relays |
50/76 |
Inverse time overcurrent relays |
51 |
Undercurrent relays |
37 |
Ground fault relays |
50 |
Directional overcurrent relays |
67 |
Directional ground fault relays |
67N |
Overvoltage relays |
59 |
Undervoltage relays |
27 |
Directional voltage relays |
91 |
Directional power relays |
32 |
Power factor relays |
55 |
Differential protection (differential circuits) |
87 |
Distance protection equipment (phase by phase) |
21 |
Negative sequence overcurrent relays |
46N |
Motor overload protection |
51/86 |
Automatic reclosing devices |
79 |
Tripping relays |
94 |
Voltage regulating relays |
|
Overimpedance relays, Z> |
|
Underimpedance relays, Z |
|
Time-delay relays |
|
Company Details
Business Type:
Manufacturer,Seller
Year Established:
1999
Total Annual:
5 MIllion-9 MIllion
Employee Number:
150~200
Ecer Certification:
Verified Supplier
Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a... Who am I ? Since its establishment in 1999, Kingsine Electric Automation Co., Ltd. has focused on researching and developing, producing, and selling Protection Relay Test Sets, CT Analyzers, Reference Power Sources and Calibrators, Voltage and Current Amplifiers, Electricity Monitoring Systems, a...
Get in touch with us
Leave a Message, we will call you back quickly!