Packaging Details | cartons |
Delivery Time | 5-10days |
Payment Terms | T/T,L/C,Western union |
Supply Ability | 30,000 |
Place of Origin | China |
Model Number | CFLP101-02 |
View Detail Information
Explore similar products
4 zones conventional fire security alarm DC24V 2 wire systems control panel
Conventional fire alarm 24V 2 wire systems control panel 4 zones
DC24V conventional fire alarm 2 wired systems control panel 4 zones
2 core wire bus conventional fire alarm systems control panel 4 zones
Product Specification
Packaging Details | cartons | Delivery Time | 5-10days |
Payment Terms | T/T,L/C,Western union | Supply Ability | 30,000 |
Place of Origin | China | Model Number | CFLP101-02 |
High Light | fire alarm ,fire alarm panel ,fire alarm system |
Electronic DC24V conventional fire alarm systems control Slave panel 2 zones
The mini 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
Specifications:
Four Style B (Class B) Initiating Device Circuits (IDCs).
One Master Panel also has two zones, each zone can connect max.25 conventional detectors.
One slave Panel has two zones, each zone can connect max.25 conventional detectors.
The Mater panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.
Mini size as 108X143X40mm
Master panel has 4 digital LED display to show slave number and status.
2 Detection Zones Panel, 25 Detectors per Zone
Fire 1 relay would be activated when one zone alarms.
Fire 2 relay would be activated after 30 seconds delay when two zones alarm.
1 Sound relay output for sound alarm
1 Fault relay output for fault condition
Zones Fire and Fault LEDs indication
Fire1, Fire2, Sound relay outputs can be activated manually
RS485 Port for repeater up to 1.2Km
Up to 31 Slave panels can be connected to one Master panel
Powered by outside DC22-26V power supply
End Of Line Status Detection, Short circuit /open circuit detection
Two modules power supply could be selected.
The power supply input is AC90-270V
Two 4AH batteries can be housed in the power supply cabinet.
Relay output contacts rated at: 2.0 amps @ 30 VDC.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2009
Employee Number:
>less than 50
Ecer Certification:
Active Member
Shenzhen KINGUI Limited was founded in 2009. We are one of the leading supplier of fire alarm system products, such as conventional and addressable fire alarm control panel, smoke and heat sensor detectors,manuel call point,sound strobe etc. We cover all aspects of production from design, R&am... Shenzhen KINGUI Limited was founded in 2009. We are one of the leading supplier of fire alarm system products, such as conventional and addressable fire alarm control panel, smoke and heat sensor detectors,manuel call point,sound strobe etc. We cover all aspects of production from design, R&am...
Get in touch with us
Leave a Message, we will call you back quickly!