Packaging Details | Wooden shaft packaging:38x26x22cm |
Delivery Time | 15-45Days |
Supply Ability | 2000pcs/day |
Payment Terms | T/T |
Color | Blue |
Transmission Speed | 1Gbps |
Certifications | UL, ETL, RCM, CPR, CSA |
Category | CAT6 |
Bandwidth | 250MHz |
Conductor Size | 23AWG |
Jacket Material | PVC |
Application | 100Base-TX/100Base-T4/100VG-AnyLan/ATM |
Brand Name | ITI-LINK |
Model Number | ITI-CT6U-0015 |
Place of Origin | shenzhen |
Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
View Detail Information
Explore similar products
CPR Certified UTP CAT6 Cable 1000ft Length For Speed Data Transfer And
Blue UTP CAT6 Cable 23AWG Extend To 550MHz CM PVC High Speed Network Cable
Bare Copper Cat6 UTP Network Cable Solid Copper Gray Extend To 550MHz 1000ft
High Speed UTP CAT6 Cable Network Cable 23AWG Solid Outdoor PE Filling Glue
Product Specification
Packaging Details | Wooden shaft packaging:38x26x22cm | Delivery Time | 15-45Days |
Supply Ability | 2000pcs/day | Payment Terms | T/T |
Color | Blue | Transmission Speed | 1Gbps |
Certifications | UL, ETL, RCM, CPR, CSA | Category | CAT6 |
Bandwidth | 250MHz | Conductor Size | 23AWG |
Jacket Material | PVC | Application | 100Base-TX/100Base-T4/100VG-AnyLan/ATM |
Brand Name | ITI-LINK | Model Number | ITI-CT6U-0015 |
Place of Origin | shenzhen | Certification | UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS |
High Light | 1000ft high speed network cable ,CAT6 high speed network cable ,UTP high speed cat 6 cable |
1. This UTP CAT6 cable has a length of 1000 feet and is designed for engineering use, making it ideal for use in large-scale cabling projects. Whether you are setting up a new network for your enterprise or upgrading an existing network, this CAT6 network cable is sure to meet your needs.
2. The outer sheath of UTP CAT6 cable is made of blue PVC and high-grade flame-retardant material is selected. The wire pairs are separated by a cross skeleton, which effectively avoids interference between electromagnetic signals. The conductor is made of 23AWG high-quality oxygen free copper, which has transmission performance higher than the standard. It can achieve 10 Gigabit Ethernet within a short distance, which makes it more advantageous than other CAT6 cables and the preferred choice for engineering cabling.
3. This CAT6 engineering specific cable has a bandwidth of 250MHz and can be extended to 550MHz. The standard transmission rate is 1Gbps, and the short distance transmission rate far exceeds the CAT6 standard transmission rate. The transmission performance is stable and can be well applied in engineering wiring.
Product Description: CAT6 U/UTP 23AWG Solid Outdoor PE+PVC Cable | ||||||
Rev.: A | ECN Description: | |||||
Construction Item Description | Electrical Property | |||||
Conductor |
Material | Bare Solid Copper(elongation: 19 ~ 24%) | Conductor Resistance at 20°C | ≤ 9.5 Ω / 100m | ||
OD | 23 AWG | Resistance unbalance within a pair | ≤ 2% | |||
Insulation |
Material |
HDPE 8303 | Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
>1500 MΩ / 100m | ||
OD | 1.14 ± 0.05 mm | Mutual capacitance | 5600 pF / 100m MAX | |||
Average THK | 0.29 mm | Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |||
Color | 1p: white + 2 blue stripes & blue | Characteristic impedance at 100MHz | 100 ± 15 Ω | |||
2p: white + 2 orange stripes & orange | Dielectric Strength Test Voltage (cd/cd,cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown | ||||
3p: white + 2 green stripes & green | Mechanical Property | |||||
4p: white + 2 brown stripes & brown |
insulation | elongation before aging | ≥ 300% | |||
Pair Twist |
Lay & Direction | 1p: S=20.0 mm (28%) | tensile strength before aging | ≥16 MPa | ||
2p: S=17.5 mm (24%)) | elongation after aging | ≥ 150 % | ||||
3p: S=22.0 mm (32%) | tensile strength after aging | ≥10.5 MPa | ||||
4p: S=15.5 mm (21%) |
jacket | elongation before aging | ≥350% | |||
OD | / | tensile strength before aging | ≥9.7MPa | |||
Inner Assemble | Lay | S=90 ± 5 mm | elongation after aging | ≥263% | ||
Direction | according to the drawing | tensile strength after aging | ≥7.3MPa | |||
Filler | / | Packing | ||||
OD | / | Inner Box | NA | |||
Filler | Material | Ripcord | Master Carton | NA | ||
Construction | 300D |
| ||||
Outside Shield | Shield | / | ||||
Construction | / | |||||
Material | / | |||||
Coverage | / | |||||
Jacket | Material | Inner Jacket: PVC + Outside Jacket: PE | ||||
Hardness | / | |||||
OD | 5.8 / 7.2 | |||||
Average THK | / | |||||
Color | according to the customer's requirements | |||||
Marking Color | according to the customer's requirements | |||||
Marking | according to the customer's requirements |
Electrical Properties | ||
Conductor Resistance at 20°C | UL 444 & CSA C22.2 No. 214 | ≤ 9.5 Ω / 100m |
Resistance unbalance within a pair | ≤ 2% | |
Dielectric Strength Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min |
No breakdown | |
Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V |
>1500 MΩ / 100m | |
Mutual capacitance | 5600pF / 100m MAX | |
Capacitance unbalance pair to ground at 800Hz or 1 kHz | ≤ 160 pF / 100m | |
Characteristic impedance at 100MHz | 100 ± 15 Ω | |
Spark Test | 2000 ± 250VOC |
Transmission Properties | |||||||||
CAT 6 U/UTP | |||||||||
No. |
Frequency |
Attenuation (Max) | Propagation Delay (MAX) | Propagation Delay Skew (MAX) |
Return Loss (Min) |
NEXT (Min) |
PS NEXT (Min) |
EL-FEXT (Min) |
PS EL-FEXT (Min) |
MHz | dB/100m | ns/100m | ns/100m | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | dB(on 100m) | |
1 | 4 | 3.78 | 552 | 45 | 23.01 | 66.27 | 63.27 | 55.96 | 52.96 |
2 | 8 | 5.32 | 546.73 | 45 | 24.52 | 61.75 | 58.75 | 49.94 | 46.94 |
3 | 10 | 5.95 | 545.38 | 45 | 25 | 60.3 | 57.3 | 48 | 45 |
4 | 16 | 7.55 | 543 | 45 | 25 | 57.24 | 54.24 | 43.92 | 40.92 |
5 | 20 | 8.47 | 542.05 | 45 | 25 | 55.78 | 52.78 | 41.98 | 38.98 |
6 | 25 | 9.51 | 541.2 | 45 | 24.32 | 54.33 | 51.33 | 40.04 | 37.04 |
7 | 31.25 | 10.67 | 540.44 | 45 | 23.64 | 52.88 | 49.88 | 38.1 | 35.1 |
8 | 50 | 13.66 | 539.09 | 45 | 22.21 | 49.82 | 46.82 | 34.02 | 31.02 |
9 | 62.5 | 15.38 | 538.55 | 45 | 21.54 | 48.36 | 45.36 | 32.08 | 29.08 |
10 | 100 | 19.8 | 537.6 | 45 | 20.11 | 45.3 | 42.3 | 28 | 25 |
11 | 125 | 22.36 | 537.22 | 45 | 19.43 | 43.85 | 40.85 | 26.06 | 23.06 |
12 | 200 | 28.98 | 536.55 | 45 | 18 | 40.78 | 37.78 | 21.98 | 18.98 |
13 | 250 | 32.85 | 536.28 | 45 | 17.32 | 40.35 | 36.33 | 20.04 | 17.04 |
14 | *300 | 31.25 | 535.76 | 45 | 18 | 41.45 | 36.33 | 20.04 | 17.04 |
15 | *350 | 33.26 | 538.54 | 45 | 19.2 | 36.36 | 36.33 | 20.04 | 17.04 |
16 | *400 | 331.25 | 537.21 | 45 | 16.38 | 40.23 | 36.33 | 20.04 | 17.04 |
17 | *450 | 28.98 | 535.87 | 45 | 19.88 | 43.26 | 36.33 | 20.04 | 17.04 |
18 | *500 | 31.85 | 537.56 | 45 | 18.65 | 40.23 | 36.33 | 20.04 | 17.04 |
Remarks: * are the reference values. |
1. The ITI-LINK ITI-CT6U-0015 UTP CAT6 cable is mainly used for engineering cabling. With its CAT6 rating, this cable can provide high-speed and reliable connections for various devices and applications. Whether you are connecting to servers, switches, routers, or other network devices, this cable provides a stable and secure connection.
2. Another common use for the ITI-LINK ITI-CT6U-0015 UTP CAT6 CABLE is in home and office networks. This cable is ideal for connecting computers, printers, and other devices to a router or modem, providing reliable and fast internet access. With its 23AWG conductor size and high-quality insulation, this cable delivers excellent performance and durability.
3. In addition to its use in networking and data transfer, the ITI-LINK ITI-CT6U-0015 UTP CAT6 CABLE can also be used for audio and video applications. Whether you are connecting a home theater system or a digital signage display, this cable provides a stable and reliable connection for high-quality audio and video signals.
4. Overall, the ITI-LINK ITI-CT6U-0015 UTP CAT6 CABLE is a versatile and reliable networking cable that is suitable for a range of applications and scenarios. With its certifications from UL, CSA, ETL, CPR, TUV, RCM, CE, and RoHS, you can be confident in its safety and quality. With a length of 1000ft and a supply ability of 1500PCS/DAY, this cable is a great choice for businesses and individuals looking for a high-quality networking solution.
Q1. What is the brand name of the UTP CAT6 Cable?
A1. The brand name of the UTP CAT6 Cable is ITI-LINK.
Q2. What is the model number of the UTP CAT6 Cable?
A2. The model number of the UTP CAT6 Cable is ITI-CT6U-0014.
Q3. Where is the UTP CAT6 Cable manufactured?
A3. The UTP CAT6 Cable is manufactured in SHENZHEN.
Q4. What certifications does the UTP CAT6 Cable have?
A4. The UTP CAT6 Cable is certified by UL, ETL, CSA, RCM, TUV, CPR, CE, and RoHS.
Q5. Can CAT6 pass the link test?
A5. Our Cat6 product has passed the 90 meter link test and can also pass the network segmentation test.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler,Exporter,Seller
Year Established:
2014
Total Annual:
100,000,000-150,000,000
Employee Number:
100~200
Ecer Certification:
Verified Supplier
New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a... New Service: Integrity Cable Co., Limited has an extremely professional and innovative service team. All of its members possess profound industry knowledge and rich practical experience. They are capable of customizing personalized technological solutions according to your specific requirements a...
Get in touch with us
Leave a Message, we will call you back quickly!