China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm
China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm

  1. China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm
  2. China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm
  3. China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm
  4. China Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm

Echo Mode Ultrasonic Thickness Gauge Meter PM-5DL OLED Screen Resolution 0.001mm

  1. MOQ: 1 Set
  2. Price:
  3. Get Latest Price
Payment Terms T/T
Supply Ability 50 Sets per Month
Delivery Time 15 Working Days
Packaging Details Carton Box
Display Color OLED Screen
Measure Mode I-E, E-E, ME-E, Auto
Display Mode A-SCAN, B-SCAN
Velocity Range 500-9999m/s
Resolution 0.001mm resolution
A-Scan Displays the whole RF echo or half-waveform
Brand Name iqualitrol
Model Number PM-5DL
Certification
Place of Origin

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T Supply Ability 50 Sets per Month
Delivery Time 15 Working Days Packaging Details Carton Box
Display Color OLED Screen Measure Mode I-E, E-E, ME-E, Auto
Display Mode A-SCAN, B-SCAN Velocity Range 500-9999m/s
Resolution 0.001mm resolution A-Scan Displays the whole RF echo or half-waveform
Brand Name iqualitrol Model Number PM-5DL
Certification Place of Origin
High Light Ultrasonic Thickness Gauge MeterUltrasonic Thickness Meter OLED Screen0.001mm Ultrasonic Thickness Tester

 

Echo Mode Ultrasonic Thickness Gauge with OLED Screen and Resolution 0.001mm


Features: 
1. High precision, 0.001mm resolution;
2. Real time A-Scan with adjustable gain, range, blanking etc;


3. Especially fits for ultra-thin work-piece, can accurately and reliably measure down to 0.2 mm;
4. Measure through coatings, e.g. coatings on the substrate, the net thickness of the substrate can be measured without removing coatings;


5. Unique multiple-wave verify mode, all the thickness values have been checked through 3 to 9 times of echos, which makes the result more reliable and accurate.

 

Technical Specifications:

Display 2.4QVGA(320×240)true color OLED screen, contrast 10000:1
Measuring Modes Interface-Echo Mode( I-E): for thick material
Echo-Echo Mode (E-E): for the thin material and measure through the coating
Multiple Echo Verify Mode (ME-E): All the thickness values have been checked through 3 to 9 times of echos, which makes the result more reliable and accurate
Auto Mode:The instrument select the measuring mode automatically according to the different material being tested
Measuring Range( Steel) Interface-Echo Mode: 1.5mm-27mm
Echo-Echo Mode: 0.25mm-13.5mm
Multiple Echo Verify Mode: 0.25mm-9mm
Auto Mode: 0.25mm-27mm
Display Mode

A-SCAN: Displays the whole RF echo or

half-waveform after rectified

B-SCAN: Real time B-Scan,

displays the profile of the work-piece

Big Thickness Value:

The conventional display of the thickness value

Difference/Thickness thinning rate: Display the difference between the real thickness value and the preset thickness value, and the percentage of the thinning value
Min./Max. Capture: Display the current thickness value, Min. value and Max. value at the same time
Gain Real time continuously adjustable, adjustable range 41dB
Measuring Resolution 0.001 mm or 0.01mm (0.0001in or 0.001in)
Material Velocity Range 500-9999m/s, 0.0197-0.3937inch/microsecond
Alarm Setting Dynamically change the color of thickness value when the measuring value exceeds the upper limit or lower limit of preset
Units Inch or Millimeter
Language Chinese, English, French, Germany, Japanese
Power 2 AA size batteries, Operating time is more than 35 hours
Instrument Shut-off Select ALWAYS ON or AUTO OFF after 5, 10 or 20 minutes of inactivity
Working Temperature -10℃ ~+50℃
Size 153mm × 76mm ×37mm(H ×W ×D)
Weight 280g including batteries
Data Recorder
Capacity 400 Files, 100,000 Thickness Values and 1000 Groups of Wave forms
File Structure Grid File
Line Number * Column Number 21*12
Communication Connector USB 2.0 Full Speed Connector
Communication Software Data View Software

 
Standard Delivery:

Ultrasonic Thickness Gauge 1
Probe 1
Probe Cable 1
Communication Cable 1
Instrument Case 1
Coupling Agent (take off ship by air) 1
Battery (take off ship by air) 2
Data Communication Software 1
User Manual, Packing List, Warranty Card 1

 

 

In any ultrasonic gaging application, the choice of gage and transducer will depend on the material to be measured, thickness range, geometry, temperature, accuracy requirements, and any special conditions that may be present. Olympus NDT can provide full details for specific applications. Listed below are the major factors that should be considered.

Material: The type of material and the range of thickness being measured are the most important factors in selecting a gage and transducer. Many common engineering materials including most metals, ceramics, and glass transmit ultrasound very efficiently and can easily be measured across a wide thickness range. Most plastics absorb ultrasonic energy more quickly and thus have a more limited maximum thickness range, but can still be measured easily in most manufacturing situations. Rubber, fiberglass, and many composites can be much more attenuating and often require high penetration gages with pulser/receivers optimized for low frequency operation.

Thickness: Thickness ranges will also dictate the type of gage and transducer that should be selected. In general, thin material are measured at high frequencies and thick or attenuating materials are measured at low frequencies. Delay line transducers are often used on very thin materials, although delay line (and immersion) transducers will have a more restricted maximum measurable thickness due to potential interference from a multiple of the interface echo. In some cases involving broad thickness ranges and/or multiple materials, more than one transducer type may be required.

Geometry: As the surface curvature of a part increases, the coupling efficiency between the transducer and the test piece is reduced, so as radius of curvature decreases the size of the transducer should generally be decreased as well. Measurement on very sharp radiuses, particularly concave curves, may require specially contoured delay line transducers or non-contact immersion transducers for proper sound coupling. Delay line and immersion transducers may also be used for measurement in grooves, cavities and similar areas with restricted access.

Temperature: Common contact transducers can generally be used on surfaces up to approximately 125° F or 50° C. Use of most contact transducers on hotter materials can result in permanent damage due to thermal expansion effects. In such cases, delay line transducers with heat-resistant delay lines, immersion transducers, or high temperature dual element transducers should always be used.

Phase Reversal: There are occasional applications where a material of low acoustic impedance (density multiplied by sound velocity) is bonded to a material of higher acoustic impedance. Typical examples include plastic, rubber, and glass coatings on steel or other metals, and polymer coatings on fiberglass. In these cases the echo from the boundary between the two materials will be phase reversed or inverted with respect to the echo obtained from an air boundary. This condition can normally be accommodated by a simple setup change in the instrument, but if it is not taken into account, readings may be inaccurate.

Accuracy: Many factors affect measurement accuracy in a given application, including proper instrument calibration, uniformity of material sound velocity, sound attenuation and scattering, surface roughness, curvature, poor sound coupling, and backwall non-parallelism. All of these factors should be considered when selected a gage and transducer. With proper calibration, measurements can usually be made to an accuracy of +/- 0.001" or 0.01 mm, and in some cases accuracy can approach 0.0001" or 0.001 mm. Accuracy in a given application can best be determined through the use of reference standards of precisely known thickness. In general, gages using delay line or immersion transducers for Mode 3 measurements are able to determine the thickness of a part most precisely.

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Distributor/Wholesaler

  • Year Established:

    2010

  • Total Annual:

    1000000-1500000

  • Employee Number:

    10~30

  • Ecer Certification:

    Site Member

  iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc.   These are widely used ...   iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc.   These are widely used ...

+ Read More

Get in touch with us

  • Reach Us
  • Dongguan Quality Control Technology Co., Ltd.
  • Room 301, Building No.1, No. 2 Jiaolian Yiheng Rd, Wanjiang District, Dongguan, China, 523046
  • https://www.iqualitrol.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement