Payment Terms | T/T |
Supply Ability | 10 Sets per Month |
Delivery Time | 20 Working Days |
Packaging Details | Plywood Box |
Model | AHL-90T |
Name | Salt Spray Corrosion Tester |
Test Temp | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ |
Solution | NaCl 5% |
Chamber | Material polyvinyl chloride |
Temp sensor | Platinum Resistance (PT-100) |
Brand Name | iqualitrol |
Model Number | AHL-90T |
Place of Origin | |
Certification |
View Detail Information
Explore similar products
ASTM B117 intelligent standard precision salt fog spray testing machine Xsalt-60
ASTM G85 Salt Spray Test Chamber Precision Salt Fog Spray Testing Machine
Programmable Touch Screen Salt Spray Chamber Environment Test Chamber For
Economical Salt Spray Environmental Test Chamber For Corrosion Resistance
Product Specification
Payment Terms | T/T | Supply Ability | 10 Sets per Month |
Delivery Time | 20 Working Days | Packaging Details | Plywood Box |
Model | AHL-90T | Name | Salt Spray Corrosion Tester |
Test Temp | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | Solution | NaCl 5% |
Chamber | Material polyvinyl chloride | Temp sensor | Platinum Resistance (PT-100) |
Brand Name | iqualitrol | Model Number | AHL-90T |
Place of Origin | Certification | ||
High Light | CASS Salt Spray Test Chamber ,Salt Spray Test Chamber PVC Material ,CASS Salt Spray Test Equipment |
Touch Controller CASS Corrosion Resistance Salt Spray Test Machine
Technical Data Download:
iqualitrol Salt Spray Test Chamber AHL-90T
Brief Introduction:
The Copper Accelerated Acetic Acid Salt Spray (CASS) test, often referred to as the Salt Fogging Test, is used to simulate and evaluate the corrosive performance of decorative copper/nickel/chromium or nickel/chromium coatings on steel, zinc or aluminium alloys and plastics designed for severe service.
Technical Specifications:
Please note: AHL-60T and AHL-90T do not meet standard of ASTM B117
Model | AHL-60T | AHL-90T | AHL-120T | AHL-160T | AHL-200T | ||
Interior dimensions (mm) | W | 600 | 900 | 1200 | 1600 | 2000 | |
D | 450 | 600 | 850 | 1000 | 1200 | ||
H | 400 | 500 | 500 | 550 | 600 | ||
Exterior dimensions (mm) | W | 1130 | 1460 | 2200 | 2600 | 3000 | |
D | 630 | 910 | 1200 | 1450 | 1650 | ||
H | 1070 | 1280 | 1450 | 1550 | 1600 | ||
Chamber Volume | 108 L | 270 L | 480 L | 800 L | 1440 L | ||
Solution Tank | 15L | 25 L | 40 L | ||||
Power Supply | AC 220V 50HZ | AC 380V 50HZ | |||||
Ambient temp. & humid. range | +5℃ ~ +35℃ / <85%RH | ||||||
Testing Temperature | NSS ACSS 35℃±1℃ / CASS 50℃±1℃ | ||||||
Air Temperature | NSS ACSS 47℃±1℃ /CASS 63℃±1℃ | ||||||
Solution Consistence | NaCl 5% | ||||||
PH Value | NASS ACSS:6.5~7.2 / CASS:3.0~3.2 | ||||||
Temperature fluctuation | ≦±0.5℃ | ||||||
Temperature uniformity | ≦2. 0℃ | ||||||
Temperature deviation | ≦±2.0℃ | ||||||
Spray quantum | 1.0~2.0(ml/80cm2/h) | ||||||
Chamber Material | polyvinyl chloride (PVC) | ||||||
Heater | Corrosion-resistant titanium tube | ||||||
Temperature sensor | Platinum Resistance (PT-100) | ||||||
Safety device | Over-temperature protection , leakage protection |
Note:
1. The above specifications are for reference only, the actual specifications for the main quotation.
2. Custom made is available according to customers’ special requirements.
The types of coatings that can be assessed through the copper accelerated acetic acid salt spray test include:
Phosphate surfaces (with successive primer, paint, rust preventive, lacquer)
Copper, tin, nickel, electroplated chromium
Zinc flake and other coatings that are not electrolytically applied
Zinc alloy and plain zinc plating
Organic coatings
This test is widely employed in industrial settings. It is very beneficial for replicated service evaluation, development and research as well as manufacturing control. Specifically, it is developed for electrodeposited, decorative chromium/nickel as well as chromium/nickel/copper.
Main Features:
1, Chamber material is made of P.V.C Sheet, sturdily and will not be out of shape.
2, Test chamber is heated from five directions to ensure the temperature is uniformity distributed.
3, Spray nozzle is specially made, enable to spray the salt water with considerable speed, then falls on the surface of samples.
4, Hot and moist air keeps the humidity in the test chamber conforms testing request.
5, High precision P.I.D. temperature controller limits the temperature difference within the range of ±0.1℃.
Company Details
Business Type:
Manufacturer,Distributor/Wholesaler
Year Established:
2010
Total Annual:
1000000-1500000
Employee Number:
10~30
Ecer Certification:
Site Member
iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc. These are widely used ... iqualitrol is a professional company to supply quality control instrument and repair service. The main products are industrial video borescope, hardness testers, metallographical instrument, metallurgical microscopes, temperature test chambers, etc. These are widely used ...
Get in touch with us
Leave a Message, we will call you back quickly!