Payment Terms | L/C, T/T, Paypal |
Supply Ability | 10000pcs per month |
Delivery Time | sample order 2 working days, bulk order 7-10 working days |
Packaging Details | Cartons 39.5*29.5*28.5cm |
Application | Cable Machine |
Model | FPR500A-15G/18.5P-T4 |
Control mode | V/F vector control |
Motor Power | 11kw/15HP |
Motor Phase | Three phase |
Input Voltage | 380-460v |
Output Voltage | 380-460v |
Rated Output Current | 32A/37A |
Warranty time | 18months |
Communication | MODBUS/ RS485 |
Speed Accuracy | ±0.5% (V/f Control) |
Brand Name | CHIFON |
Model Number | FPR500A-15G/18.5P-T4 |
Certification | CE,ISO,SGS,EAC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Vector Single Phase VFD 2hp 1.5kw Variable Frequency Drive For Single Phase
Single Phase VSD Pump Control 2.2kw 3 Hp VFD Drive 220v EAC For Water Pump
380V 22KW VSD Motor Control Frequency Converter VFD Inverter Drive For Motor
SGS VSD Pump Control 380V 200kw Variable Speed Drive For 3 Phase Motor
Product Specification
Payment Terms | L/C, T/T, Paypal | Supply Ability | 10000pcs per month |
Delivery Time | sample order 2 working days, bulk order 7-10 working days | Packaging Details | Cartons 39.5*29.5*28.5cm |
Application | Cable Machine | Model | FPR500A-15G/18.5P-T4 |
Control mode | V/F vector control | Motor Power | 11kw/15HP |
Motor Phase | Three phase | Input Voltage | 380-460v |
Output Voltage | 380-460v | Rated Output Current | 32A/37A |
Warranty time | 18months | Communication | MODBUS/ RS485 |
Speed Accuracy | ±0.5% (V/f Control) | Brand Name | CHIFON |
Model Number | FPR500A-15G/18.5P-T4 | Certification | CE,ISO,SGS,EAC |
Place of Origin | CHINA | ||
High Light | 3 Phase VSD Pump Control ,15KW VSD Pump Control ,VFD AC Drive Inverter |
Water Pump Motor Control 15KW 3-Phases VFD Frequency Inverter AC Drive
Technical characteristics
Drive motor type:Ac asynchronous motor, Ac permanent magnet synchronous motor
Four control modes:PG vector control(FVC), PG-free vector control(SVC),
V / F control, Torque control
Speed control range:PG vector control(FVC)1:1000
PG- free vector control(SVC)1:200
V / F control 1:50
Speed control accuracy:PG vector control (FVC)±0.2%
PG- free vector control (SVC)±0.5%
Starting torque:PG vector control(FVC):180 % rated torque/0.01Hz
PG- free vector control (SVC)150% rated torque/0.25Hz
Torque control accuracy:PG vector control (FVC)±5%
PG- free vector control (SVC)±8%
Multi-motor switching: Two groups of motor parameters can realize the switching control of the two motors.
Motor overheating protection:Optional IO expansion card, analog A / 3 can accept input from the motor temperature sensor
Supports multiple encoders:Supports differential, open collector, uvw, rotary transformer, sine and cosine encoder
Torque limitation and control: the "excavator" feature, automatically limits the torque during operation to prevent frequent overcurrent trips. Closed-loop mode can realize torque control.
Product advantages
Single-speed starting methods start motors abruptly, subjecting the motor to a high starting torque and to current surges that are up to 10 times the full-load current. Variable speed drives, on the other hand, gradually ramp the motor up to operating speed to lessen mechanical and electrical stress, reducing maintenance and repair costs, and extending the life of the motor and the driven equipment.
Soft starts, or reduced-voltage soft starters (RVSS), are also able to step a motor up gradually, but drives can be programmed to ramp up the motor much more gradually and smoothly, and can operate the motor at less than full speed to decrease wear and tear. Variable speed drives can also run a motor in specialized patterns to further minimize mechanical and electrical stress. For example, an S-curve pattern can be applied to a conveyor application for smoother decel/accel control, which reduces the backlash that can occur when a conveyor is accelerating or decelerating.
At the instant of energization, the locked rotor (zero-speed) is about 600% of full-load running current This heavy current then drops off gradually as the load breaks loose, and the motor comes up to speed, but causes unacceptable voltage sag on the power system, adversely affecting other loads. It can also cause shock damage and long-term excessive wear on the motor. Using this starting method may force the utility to impose a limit on the size of motors you can use, since across-the-line starting causes problems upstream into the utility's system, creating problems for other customers. The switching surges of abruptly starting and stopping create stress on the motor insulation.
Packaging:
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
5000000-10000000
Employee Number:
100~120
Ecer Certification:
Active Member
Zhejiang Chifon electric Co., Ltd. is a high-tech enterprise specializing in research, development, manufacture, and sales of electric drive, industrial control, and motor energy-saving technology products. The company has completely independent intellectual property rights and several national ... Zhejiang Chifon electric Co., Ltd. is a high-tech enterprise specializing in research, development, manufacture, and sales of electric drive, industrial control, and motor energy-saving technology products. The company has completely independent intellectual property rights and several national ...
Get in touch with us
Leave a Message, we will call you back quickly!