Payment Terms | L/C, T/T, Paypal |
Supply Ability | 10000pcs per month |
Delivery Time | sample order 2 working days, bulk order 7-10 working days |
Packaging Details | Cartons 24*18*21cm |
Case Material | Plastics |
Model | FPR500A-0.75G-S2 |
Motor Power | 0.75kw/1HP |
Motor Phase | Single phase |
Input Voltage | 220-240v |
Output Voltage | 380-460v |
Frequency | 50/60Hz |
Color | Grey |
OEM | Yes |
Outer size | 185*118*157mm |
Wall-mounted | Yes |
Warranty period | 1.5years |
Brand Name | CHIFON |
Model Number | FPR500A-0.75G-S2 |
Certification | CE,ISO,SGS,EAC |
Place of Origin | CHINA |
View Detail Information
Explore similar products
Vector Single Phase VFD 2hp 1.5kw Variable Frequency Drive For Single Phase
Single Phase VSD Pump Control 2.2kw 3 Hp VFD Drive 220v EAC For Water Pump
380V 22KW VSD Motor Control Frequency Converter VFD Inverter Drive For Motor
SGS VSD Pump Control 380V 200kw Variable Speed Drive For 3 Phase Motor
Product Specification
Payment Terms | L/C, T/T, Paypal | Supply Ability | 10000pcs per month |
Delivery Time | sample order 2 working days, bulk order 7-10 working days | Packaging Details | Cartons 24*18*21cm |
Case Material | Plastics | Model | FPR500A-0.75G-S2 |
Motor Power | 0.75kw/1HP | Motor Phase | Single phase |
Input Voltage | 220-240v | Output Voltage | 380-460v |
Frequency | 50/60Hz | Color | Grey |
OEM | Yes | Outer size | 185*118*157mm |
Wall-mounted | Yes | Warranty period | 1.5years |
Brand Name | CHIFON | Model Number | FPR500A-0.75G-S2 |
Certification | CE,ISO,SGS,EAC | Place of Origin | CHINA |
High Light | EAC Single Phase Motor VSD ,Vector 2hp Single Phase Motor VSD ,3hp Variable Frequency Drive |
Europe hot-sale Single Phase 220v Vector VSD 1hp 2hp 3hp For Water Pump Control
Power class
Low voltage
Single-phase 220v±15% 0.4-2.2kw
Three-phase 380V±15% 0.75-315kw
Maintenance of VFD
Many applications that utilize a variable frequency drive (VFD) are critical and can’t afford to have extensive downtime. One option that many opt for is to keep a spare VFD on the shelf, ready to switch out if the need arises. If you are not careful, however, that VFD may not be ready to use when you need it. Below are several things to look for to make sure your spare VFD is ready to pull from long term storage and put right in to service.
One of the easiest issues to address is where and how you are storing the VFD. Make sure that it is cool, clean, and dry. Common issues we see are that the warehouse where a spare VFD is stored has excessive moisture, dust, or even animal problems. The number of issues we have seen when mice or other animals decide to make nests in VFDs is higher than most people realize, and dust and water always present a problem.
Another issue to monitor is temperature. Most inverters are rated to run at temperature similar to 0-40°C. VFDs can be stored at slightly more extreme temperatures than they can be run at, but make sure to consult the manual for your VFDs to find what conditions are recommended.
Electrolytic capacitors are used in almost all low voltage drives, and some medium voltage as well. These capacitors are filled with an electrolytic gel which gives them their name. As these capacitors sit without being used, the gel starts to dry up and cause issues. Some medium voltage VFDs use dry film capacitors which do not encounter these problems, so a crucial aspect of servicing your drives is to identify what type of components are inside.
One of the best things you can do for your VFD is to energize it yearly. When you perform the annual preventative maintenance on your other drives, find a way to energize the stored VFD. If electrolytic capacitors sit for more than a year without being energized, you need to make sure to reform the capacitors before putting it into service, which takes valuable time at what could be a moment when your process is down. Most electrolytic capacitors only have a 5-7 year shelf life, so if you go too long without energizing or reforming capacitors, you may find it is too late to save the VFD without performing actual repairs.
One issue with just reforming capacitors on VFDs is that you can only reform the DC bus capacitors, and capacitors that are on the printed circuit boards are not reformed. That is why the best recommendation is to actually go a step past energizing stored VFDs every year and to actually rotate out equipment at every annual preventative maintenance service to keep all VFDs in their best-running shape.
Products Specifications:
Basic Function | Specification | |
Maximum output frequency | 0~500Hz | |
Carrier frequency | 0.5kHz~16.0kHz;According to the load characteristics, carrier frequency can be adjusted automatically | |
Input frequency | Range :47~63Hz | |
Control mode | V/F Open/closed loop vector control(SVC/FVC) | |
Speed range | 1:50(Vector mode 0 ) 1Hz/150% rated torque | |
Overload capability | G type:150% rated current for 60s; 180% rated current for 3s P type:120% rated current for 60s; 150% rated current for 3s | |
Torque boost | Auto Torque boost Manual Torque boost; 0.1%~30.0%. | |
V/F curve V/F | Four modes : Line , Multi-point , Square V/F curve, V/F separation | |
Jog control | Jog frequency range:0.00Hz to F0-10(Max frequency) | |
Accelerate/Decelerate curve | Line or S-curve Acc/Dec mode, four kinds of Acc/Dec time Range of Acc/Dec Time0.0~65000.00s. | |
DC brake | DC brake frequency: 0.00Hz to Maximum frequency brake time: 0.0 to 36.0s brake current value: 0.0 to 100% | |
Simple PLC, Multi-speed | 16-speed operating through built-in PLC or control terminal | |
Built-in PID | Close loop control system can be formed easily by using PID | |
Automatic voltage regulating (AVR) | Output voltage is regulated when voltage of the power network changes | |
Overvoltage and over current stall control | During operation automatically limits the inverter output current and bus voltage, to prevent fan over current and overvoltage trip. | |
Rapid current limiting function | Minimizing flow failures, protect the normal operation of the inverter | |
Instantaneous stop non-stop | Load feedback energy compensation voltage is reduced and continues to maintain a short time when change is momentarily interrupted. | |
Speed tracking start | For high-speed rotation of the motor speed identification, impact- free smooth start | |
Rapid current limit | Rapid software and hardware limiting technology to avoid frequent converter over current fault. | |
Virtual IO | Five sets of virtual DO, five sets of virtual DI, enables easy logic control. | |
Timing Control | Timing control: set the time range 0.0Min~6500.0Hour | |
Multi-motor switch | Two independent motor parameters, enabling two motors switching control | |
Bus Support | Two independent Modbus communication, CAN-Link | |
Command source | Given the control panel, control terminal, serial communication port given. It can be switched by a variety of ways. | |
Torque boost | Auto Torque boost Manual Torque boost ; 0.1%~30.0%. | |
Frequency source | Nine kinds of frequency sources: digital setting, analog voltage setting, analog current setting, pulse setting, or serial port and so on. It can be switched by a variety of ways. | |
Auxiliary frequency source | Nine kinds of auxiliary frequency source. Flexible implementation of auxiliary frequency tuning, frequency synthesis. | |
Input terminal | Six digital input terminals, one only supports 50khz high pulse input Two analog input terminals, one support 0V~10V voltage input One support 0 ~ 10V voltage input or 0 ~ 20mA current input | |
Output terminal | One high-speed pulse output terminal (optional open collector type), support of square wave 0 ~ 50kHz signal output One digital output terminal One relay output terminals Two analog output terminals, support 0 ~ 20mA current output or 0 ~ 10V voltage output | |
Display and operation | ||
LED display | Display parameters and status information | |
The key lock and function selection | Achieve some or all of the keys locked, scope definition section keys to prevent misuse. | |
Protection function | Input/output phase failure protection ,Overcurrent protection ;Over voltage protection; Undervoltage protection; Overheat protection ; Overload protection | |
Options | Brake assembly, PG card | |
Environment | ||
Application environment | In-door, free from direct sunlight, dust , corrosive gas, combustible gas, oil mist , steam , water drop and salt . | |
Altitude | Lower than 1000m | |
Vibration | Less than 5.9m/s(0.6g) |
Factory tour:
Quality certificates:
Company Details
Business Type:
Manufacturer
Year Established:
2015
Total Annual:
5000000-10000000
Employee Number:
100~120
Ecer Certification:
Active Member
Zhejiang Chifon electric Co., Ltd. is a high-tech enterprise specializing in research, development, manufacture, and sales of electric drive, industrial control, and motor energy-saving technology products. The company has completely independent intellectual property rights and several national ... Zhejiang Chifon electric Co., Ltd. is a high-tech enterprise specializing in research, development, manufacture, and sales of electric drive, industrial control, and motor energy-saving technology products. The company has completely independent intellectual property rights and several national ...
Get in touch with us
Leave a Message, we will call you back quickly!