Ecer asks for your consent to use your personal data to:
Personalised advertising and content, advertising and content measurement, audience research and services development
Store and/or access information on a device
Your personal data will be processed and information from your device (cookies, unique identifiers, and other device data) may be stored by, accessed by and shared with 135 TCF vendor(s) and 65 ad partner(s), or used specifically by this site or app.
Some vendors may process your personal data on the basis of legitimate interest, which you can object to by do not consent. Contact our platform customer service, you can also withdraw your consent.
Your message must
be between 20-3,000 characters!
Submit Requirement
Thank You!
Your requirement has been sent. we will contact you quickly!
{"title":"IFM Pressure sensor with display PN7099 PN-1-1BRER14-QFRKG\/US\/ \/V in stock","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1a\/b4\/017b8835b9341ff2e2cd9bbdc5f9-200x200-1\/ifm_pressure_sensor_with_display_pn7099_pn_1_1brer14_qfrkg_2fus_2f_2fv_in_stock.jpg","attrs":{"Brand Name":"IFM","Model Number":"PN7099","Certification":"rohs","Place of Origin":"ROMANIA"}}
{"title":"Balluff BIS00JH BIS C-380-06\/06-00,3 Data coupler for the LF range (70\/455 kHz)","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/3b\/9f\/2ff3887cbe283b682ae39d899add-200x200-1\/balluff_bis00jh_bis_c_380_06_2f06_00_2c3_data_coupler_for_the_lf_range_2870_2f455_khz_29.jpg","attrs":{"Brand Name":"balluff","Model Number":"BIS00JH","Certification":"ce","Place of Origin":"Germany"}}
{"title":"Balluff BCS004K BCS M30BBM3-PPC20C-EP02 Cylindrical version with M30 thread","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/b1\/dd\/daf86554a93d657e582f471fdb61-200x200-1\/balluff_bcs004k_bcs_m30bbm3_ppc20c_ep02_cylindrical_version_with_m30_thread.jpg","attrs":{"Brand Name":"balluff","Model Number":"BCS M30BBM3-PPC20C-EP02","Certification":"ce","Place of Origin":"Germany"}}
{"title":"Balluff BTL110J BTL7-A100-M0400-A8-KA00,2-ZA0Z Magnetostrictive linear position","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/14\/eb\/93d6287e9083d83617c63c8ed0c4-200x200-1\/balluff_btl110j_btl7_a100_m0400_a8_ka00_2c2_za0z_magnetostrictive_linear_position_sensors_in_rod_design.jpg","attrs":{"Brand Name":"balluff","Model Number":"BTL7-A100-M0400-A8-KA00,2-ZA0Z","Certification":"ce","Place of Origin":"Germany"}}
{"title":"IFM Pressure sensor with display PN2093 PN-025-RER14-MFRKG\/US\/ \/V in stock","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/1a\/b4\/017b8835b9341ff2e2cd9bbdc5f9-200x200-1\/ifm_pressure_sensor_with_display_pn2093_pn_025_rer14_mfrkg_2fus_2f_2fv_in_stock.jpg","attrs":{"Brand Name":"IFM","Model Number":"PN2093","Certification":"rohs","Place of Origin":"ROMANIA"}}
{"title":"IFM Cooling water control panel ZZ0057 KWST WITH BALANCING VALVES in stock","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/9a\/4c\/b6dc79d0b53250e588c33bfbb777-200x200-1\/ifm_cooling_water_control_panel_zz0057_kwst_with_balancing_valves_in_stock.jpg","attrs":{"Brand Name":"IFM","Model Number":"ZZ0057","Certification":"rohs","Place of Origin":"GERMANY"}}
{"title":"IFM Flow monitor SI5000 SID10ABBFPKG\/US-100 in stock","imgUrl":"https:\/\/img.silkroadsl.com\/nimg\/4b\/ad\/1ecdf7c21bafb385944a294fcd81-200x200-1\/ifm_flow_monitor_si5000_sid10abbfpkg_2fus_100_in_stock.jpg","attrs":{"Brand Name":"IFM","Model Number":"SI5000","Certification":"rohs","Place of Origin":"GERMANY"}}
flush mountable for the food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Medium temperature[°C]
-25...125; (145 max. 1h)
Min. bursting pressure
30000 mbar
12000 inH2O
3000 kPa
Pressure rating
6000 mbar
2400 inH2O
600 kPa
Type of pressure
relative pressure
No dead space
yes
Electrical data
Operating voltage[V]
14...30 DC
Min. insulation resistance[MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Measuring principle
hydrostatic
Inputs / outputs
Number of inputs and outputs
Number of analogue outputs: 1
Outputs
Total number of outputs
1
Output signal
analogue signal
Number of analogue outputs
1
Analogue current output[mA]
4...20
Max. load[Ω]
550; (Ub = 24 V; (Ub - 13 V) / 20 mA)
Overload protection
yes
Measuring/setting range
Measuring range
-0.0125...0.25 bar
-12.5...250 mbar
-5...100.4 inH2O
-1.25...25 kPa
Analogue start point
-12.5...100 mbar
-5...40.2 inH2O
-1.25...10 kPa
Analogue end point
50...250 mbar
20.2...100.4 inH2O
5...25 kPa
In steps of
0.5 mbar
0.2 inH2O
0.05 kPa
Factory setting
ASP = 0.0 mbar
AEP = 250.0 mbar
Accuracy / deviations
Repeatability[% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation[% of the span]
< ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)
Linearity deviation[% of the span]
< ± 0,5; (Turn down 1:1)
Hysteresis deviation[% of the span]
< ± 0,1; (Turn down 1:1)
Long-term stability[% of the span]
< ± 0,1; (Turn down 1:1; per year)
Temperature coefficient zero point[% of the span / 10 K]
< ± 0,1; (0...80 °C)
Temperature coefficient span[% of the span / 10 K]
< ± 0,4; (0...80 °C)
Response times
Max. response time analogue output[ms]
3
Software / programming
Parameter setting options
zero point; span
Interfaces
Communication interface
EPS
Operating conditions
Ambient temperature[°C]
-25...80
Storage temperature[°C]
-40...100
Protection
IP 67
Product characteristics
Number of inputs and outputs
Number of digital outputs: 2
Measuring range
-1...1 bar
-1000...1000 mbar
-14.5...14.5 psi
-29.4...29.4 inHg
-100...100 kPa
Process connection
threaded connection G 1/4 internal thread
Application
Special feature
Gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Application
for industrial applications
Media
liquids and gases
Medium temperature[°C]
-25...80
Min. bursting pressure
30000 mbar
450 psi
880 inHg
3000 kPa
Pressure rating
10000 mbar
145 psi
290 inHg
1000 kPa
Vacuum resistance
-1000 mbar
-0.1 MPa
Type of pressure
relative pressure; vacuum
Electrical data
Operating voltage[V]
18...30 DC; (to SELV/PELV)
Current consumption[mA]
< 35
Min. insulation resistance[MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Power-on delay time[s]
< 0.3
Integrated watchdog
yes
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 2
Outputs
Total number of outputs
2
Output signal
switching signal; IO-Link; (configurable)
Electrical design
PNP/NPN
Number of digital outputs
2
Output function
normally open / normally closed; (parameterisable)
Max. voltage drop switching output DC[V]
2.5
Permanent current rating of switching output DC[mA]
150; (200 (...60 °C) 250 (...40 °C))
Switching frequency DC[Hz]
< 170
Short-circuit protection
yes
Type of short-circuit protection
pulsed
Overload protection
yes
Measuring/setting range
Measuring range
-1...1 bar
-1000...1000 mbar
-14.5...14.5 psi
-29.4...29.4 inHg
-100...100 kPa
Factory setting / CMPT = 2
Set point SP
-980...1000 mbar
-14.3...14.5 psi
-29...29.6 inHg
-98...100 kPa
Reset point rP
-990...990 mbar
-14.4...14.4 psi
-29.4...29.2 inHg
-99...99 kPa
Min. difference between SP and rP
10 mbar
0.2 psi
0.4 inHg
1 kPa
In steps of
10 mbar
0.1 psi
0.2 inHg
0.1 kPa
Status_B High Resolution / CMPT = 3
Set point SP
-983...1000 mbar
-14.3...14.5 psi
-29...29.5 inHg
-98...100 kPa
Reset point rP
-993...990 mbar
-14.4...14.4 psi
-29.3...29.2 inHg
-99...99 kPa
Min. difference between SP and rP
10 mbar
0.2 psi
0.3 inHg
1 kPa
In steps of
1 mbar
0.1 psi
0.1 inHg
0.1 kPa
Accuracy / deviations
Switch point accuracy[% of the span]
< ± 0,5
Repeatability[% of the span]
< ± 0,1; (with temperature fluctuations < 10 K)
Characteristics deviation[% of the span]
< ± 0,25 (BFSL) / < ± 0,5 (LS); (BFSL = Best Fit Straight Line; LS = limit value setting)
Hysteresis deviation[% of the span]
< ± 0,25
Long-term stability[% of the span]
< ± 0,05; (per 6 months)
Temperature coefficient zero point[% of the span / 10 K]
< ± 0,2; (-25...80 °C)
Temperature coefficient span[% of the span / 10 K]
< ± 0,2; (-25...80 °C)
Response times
Response time[ms]
< 3
Delay time programmable dS, dr[s]
0...50
Software / programming
Parameter setting options
hysteresis / window; normally open / normally closed; switching logic; switch-on/switch-off delay; Damping; Display unit
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
SIO mode
yes
Required master port type
A; (when pin 2 not connected: B)
Process data analogue
1
Process data binary
2
Supported DeviceIDs
Type of operation
DeviceID
Factory setting / CMPT = 2
406
PN7009
314
Status_B High Resolution / CMPT = 3
604
Note
For further information please see the IODD PDF file under "Downloads"
Factory setting / CMPT = 2
Profiles
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis
Min. process cycle time[ms]
2.3
IO-Link resolution pressure
1 mbar
0.0001 MPa
IO-Link process data (cyclical)
function
bit length
pressure
14
binary switching information
2
IO-Link functions (acyclical)
application specific tag
Status_B High Resolution / CMPT = 3
Profiles
Smart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
Min. process cycle time[ms]
3
IO-Link resolution pressure
1 mbar
0.0001 MPa
IO-Link process data (cyclical)
function
bit length
pressure
16
device status
4
binary switching information
2
IO-Link functions (acyclical)
application specific tag
Operating conditions
Ambient temperature[°C]
-25...80
Storage temperature[°C]
-40...100
Protection
IP 65; IP 67
We can shipping all over the world.via DHL,UPS,Fedex and EMS, the packaging is very safe and strong. if you have any special needs,please notify me.
•It will take 3 to 7days to reach in your hands.China Post delivery schedule will be in 20-45 days. If you can't wait, please choose other express.
Our Advantage:
Best possible prices and delivery time
Long time experience in the field
Well trained staff
Own warehouse facilities
Best relationships with branch office of manufacture
Flexible and individual service for you
Cheap and safe forwarder for shipments (air)
Company Details
Bronze Gleitlager
,
Bronze Sleeve Bushings
and
Graphite Plugged Bushings
from Quality China Factory
Business Type:
Manufacturer,Distributor/Wholesaler,Trading Company
Year Established:
1998
Total Annual:
7000000-10000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ).
For more than 25 years, we have successfully execute... Great System In.(GSI) a name synonymous with Process Control Instrumentation and Electrical and Instrument and Solution Provider have established themselves as a Quality Leader since its inception in 1998 based at Hong Kong ( China ).
For more than 25 years, we have successfully execute...