Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram |
Supply Ability | 36,000,00pcs per year |
Delivery Time | Within 7 days |
Packaging Details | Carton packing for one sets, one set including three piece with Components |
Feature | Improve the Filth and Moisture Resistance |
Highest Voltage for Equipment | 24KV |
Termal Limit Output | 2500VA |
Rated Primary Voltage | 20/22KV |
Technical Standard | 0.2;0.5;1;0.2/0.2;0.2/0.5;0.2/6P;0.5/6P |
Rated Insulation Level | 24/50/150KV |
Type | Three-Phase |
Standard | IEEE |
Brand Name | Chuangyin |
Model Number | JSZV18-24RJ |
Certification | Kema,CE,SGS,TUV |
Place of Origin | Shenzhen |
View Detail Information
Explore similar products
12kV Indoor Dry type / Epoxy resin type Single phase voltage transformer JDZ(J)
JDZX16-12R 12kV Indoor Single-Phase with fuse Epoxy Resin Type MV Voltage
JDZX16-12R 12kV Indoor Single-Phase Transformer MV Voltage Transformer Potential
JDZ16-12R 12kV Indoor Transformer MV Voltage Transformer Potential transformer
Product Specification
Payment Terms | L/C, D/A, D/P, T/T, Western Union, MoneyGram | Supply Ability | 36,000,00pcs per year |
Delivery Time | Within 7 days | Packaging Details | Carton packing for one sets, one set including three piece with Components |
Feature | Improve the Filth and Moisture Resistance | Highest Voltage for Equipment | 24KV |
Termal Limit Output | 2500VA | Rated Primary Voltage | 20/22KV |
Technical Standard | 0.2;0.5;1;0.2/0.2;0.2/0.5;0.2/6P;0.5/6P | Rated Insulation Level | 24/50/150KV |
Type | Three-Phase | Standard | IEEE |
Brand Name | Chuangyin | Model Number | JSZV18-24RJ |
Certification | Kema,CE,SGS,TUV | Place of Origin | Shenzhen |
High Light | medium voltage potential transformer ,single phase voltage transformer |
12kV Indoor Medium Voltage Transformer PT Epoxy Resin Type with fuse IEEE Bushing Enclosed Support Construction for Switchgear
1. Product Introduction:
JSZV18-24RJ voltage transformer, is fully enclosed casting insulation structure, the primary winding, secondary winding and the annular core all coating in the epoxy resin casting, The product adds elbow type plug part, improving the filth and moisture resistance, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 24 kV
Main technical parameter
1. Rated primary voltage: 20kV or 22kV
2. Rated secondary voltage:100V,100/100V,100/220V
3. Rated voltage of residual voltage windings:100/ 3V ,110/ 3V, 115/ 3V, 120/ 3V
4. Burden power factor: cosΦ=0.8(lagging)
5. Standards: IEC60044-2.2003 or IEC61869-1&3
Other technical parameters pls see as follow:
Type | Rated primary voltage (kV) | Rated secondary voltage (kV) | Accuracy classes combination | Rated output (VA) | Thermal limiting current (VA) | Rated insulation level(kV) |
JSZV18-24RJ | 20 22 | 0.1 0.11 | 0.2 | 40 | 2000 | 24/50/150 |
0.5 | 80 | |||||
1 | 100 | |||||
0.1/0.1 0.11/0.11 | 0.2/0.2 | 20/20 | 500/500 | |||
0.2/0.5 | 20/30 | |||||
0.1/0.22 0.11/0.22 | 0.2/6P(3P) | 50/800 | 800/2000 | |||
0.5/6P(3P) | 50/800 |
Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Outline drawing
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
2002
Total Annual:
9210000-15350000
Employee Number:
500~999
Ecer Certification:
Verified Supplier
Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard... Company information: Shenzhen Chuangyin Co., Ltd has three manufacturing bases ,they are Jiangxi Chuangyin Co.,Ltd, Zhuhai Chuangyin Co.,Ltd and Joint-Venture Adex-Chuangyin Electric Co.,Ltd(Bangladesh); with 40,000 square meters of modern standard...