China factories

China factory - Shanghai I Fluid Technology Co., Ltd.

Shanghai I Fluid Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Clean Water Electromagnetic Water Flow Meter Ptfe Liner For Utility Billing
China Clean Water Electromagnetic Water Flow Meter Ptfe Liner For Utility Billing

  1. China Clean Water Electromagnetic Water Flow Meter Ptfe Liner For Utility Billing
  2. China Clean Water Electromagnetic Water Flow Meter Ptfe Liner For Utility Billing

Clean Water Electromagnetic Water Flow Meter Ptfe Liner For Utility Billing

  1. MOQ: 50
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, D/P, Western Union
Supply Ability 1000 sets per month
Delivery Time 2-4 weeks
Packaging Details carton / box
Name water utility billing meter
Pipe Diameter DN50 - DN200 / 2 inch - 8 inch
Liner material PTFE
Tube material SS316
Electrode 316L / Hasteloy-C / Ti / Ta / Pt100
Accuracy 0.25% , 0.5%
Communication BACNET/Modbus/RS485/4-20 mA
Totalizer Remote / Compact
Brand Name Iflow
Model Number YF-E80-1
Certification ISO9001, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/P, Western Union Supply Ability 1000 sets per month
Delivery Time 2-4 weeks Packaging Details carton / box
Name water utility billing meter Pipe Diameter DN50 - DN200 / 2 inch - 8 inch
Liner material PTFE Tube material SS316
Electrode 316L / Hasteloy-C / Ti / Ta / Pt100 Accuracy 0.25% , 0.5%
Communication BACNET/Modbus/RS485/4-20 mA Totalizer Remote / Compact
Brand Name Iflow Model Number YF-E80-1
Certification ISO9001, CE Place of Origin China
High Light commercial flow meter sanitary flow meter

Clean water utility billing by electromagnetic flowmeter Communication Bacnet DN80

 

Work theory:

The magnetic flowmeters use Faraday’s Law of Electromagnetic Induction to determine the flow of liquid in a pipe. In a magnetic flowmeter, a magnetic field is generated and channeled into the liquid flowing through the pipe. Following Faraday’s Law, flow of a conductive liquid through the magnetic field will cause a voltage signal to be sensed by electrodes located on the flow tube walls. When the fluid moves faster, more voltage is generated. Faraday’s Law states that the voltage generated is proportional to the movement of the flowing liquid. The electronic transmitter processes the voltage signal to determine liquid flow. By comparison to many other flowmeter technologies, magnetic flowmeter technology produces signals that are linear with flow. As such, the turndown associated with magnetic flowmeters can approach 20:1 or better without sacrificing accuracy. They represent about 23% of all flowmeters sold.

 

Applications:

Electromagnetic Flow Meter reduces lifecycle costs and unplanned shutdowns by accurately measuring water and wastewater flows in a variety of utility applications. It help users take advantage of improved installation, maintenance and process-management practices. With fully welded sensor construction and an isolated, replaceable termina, it is the most dependable meter available for utility and water applications.

 

Key features

  • Maximal uptime with dual-compartment transmitter housing that isolates electronics from moisture and contamination
  • Robust structure, fully welded construction designed to withstand sustained vibration
  • Confirm meter calibration without interrupting the process using continuous meter verification
  • Perform easy repairs in the field without the need to replace the entire meter with a replaceable terminal block
  • Advanced diagnostic capabilities and printed reports verify meter performance for compliance with regulatory agencies
  • Simplify configuration and accessibility with an easy-to-use Local Operator Interface

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Product name Electromagnetic flowmeter
Product type Local|compact display Remote display Signal converter
Model IYF-E IYF-F IRT
Pipe Diameter (mm) DN10-DN2000
Power supply 100-240 VAC / 18-36 VDC
Accuracy + 0.5% + 0.5% + 0.5%
Power consumption <6w <6w <6w
Enclosure rating IP65 IP68 IP65
Liquid temperature -25-120℃ -25-120℃ -25-120℃
Ambient temperature -25-50℃ -25-50℃ -25-50℃
Relative humidity 10-90% 10-90% 10-90%
Meter ratio 1:100 1:100 1:100
Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

 

Manufacture process

Packing

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1966

  • Total Annual:

    15000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai I Fluid Technology Co., Ltd.
  • Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
  • http://www.industrial-watermeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement