Payment Terms | T/T, L/C, D/P, Western Union |
Supply Ability | 1000 sets per month |
Delivery Time | 2-4 weeks |
Packaging Details | carton / box |
Description | sewage flow meter |
Power | 85-265V AC / 8-36V DC |
Diameter | 2 inch - 48 inch |
Accuracy | 1%, 1.5% |
Electrode | 316L / Hasteeloy-C / Ti / Ta / Pt100 |
Liner | Rubber, PTFE |
Totalizer | compact / remote |
Flow transducer | electromagnetic flowmeter |
Brand Name | Iflow |
Model Number | YF-E150-1 |
Certification | ISO9001, CE |
Place of Origin | China |
View Detail Information
Explore similar products
Electromagnetic Slurry / Wastewater Flow Meter Ip65 With 1% 1.5% Accuracy
Remote Reading Multi Jet Water Meter , Grey Iron Housing Pulse Output Flow Meter
Flow Rate R 80 100 House Water Meter Reed Switch PN16 Residential Anti Fog
Class B DN40 Industrial Water Meter Grey Iron ISO 4064 Housing Pulse Emitter
Product Specification
Payment Terms | T/T, L/C, D/P, Western Union | Supply Ability | 1000 sets per month |
Delivery Time | 2-4 weeks | Packaging Details | carton / box |
Description | sewage flow meter | Power | 85-265V AC / 8-36V DC |
Diameter | 2 inch - 48 inch | Accuracy | 1%, 1.5% |
Electrode | 316L / Hasteeloy-C / Ti / Ta / Pt100 | Liner | Rubber, PTFE |
Totalizer | compact / remote | Flow transducer | electromagnetic flowmeter |
Brand Name | Iflow | Model Number | YF-E150-1 |
Certification | ISO9001, CE | Place of Origin | China |
High Light | volumetric water meter ,industrial water meter |
sewage flow meter payable by magnetic flowmeter Dia: DN150 Liner: rubber
Product description:
The electromagnetic Flow Meter Sensors are designed for stable flow measurement in sewage, waste water and slurry applications. It reduces process variability by providing the most stable flow output available. The increased signal strength, coupled with advanced signal processing and superior filtering techniques provides the ideal solution to demanding flow-measurement applications, including those in the mining and pulp and paper industries.
Work principle
The Magnetic flowmeters are often used where the liquid is fed using gravity. Be sure that the orientation of the flowmeter is such that the flowmeter is completely filled with liquid. Failure to ensure that the flowmeter is completely filled with liquid can significantly affect the flow measurement. Be especially careful when operating magnetic flowmeters in vacuum service because some magnetic flowmeter liners can collapse and be sucked into the pipeline in vacuum service, catastrophically damaging the flowmeter. Note that vacuum conditions can occur in pipes that seemingly are not exposed to vacuum service such as pipes in which a gas can condense (often under abnormal conditions). Similarly, excessive temperature in magnetic flowmeters (even briefly under abnormal conditions) can result in permanent flowmeter damage.
Industries Where Used
In order of usage, water/wastewater industry, chemical, food and beverage, oil and gas (although not for oil and gas fluids but in support of the processes), power, pulp and paper, metals and mining, and pharmaceutical.
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Production line
Calibration equipment
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1966
Total Annual:
15000000-20000000
Employee Number:
400~500
Ecer Certification:
Active Member
Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote...
Get in touch with us
Leave a Message, we will call you back quickly!