Turbine Industrial Water Flow Meter For Municipal Water Utility And Food

  1. MOQ: 50
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, D/P, Western Union
Supply Ability 1000 sets per month
Delivery Time 2-4 weeks
Packaging Details carton / box
Name Flow meter for clean water
Power supply 85 - 265V AC / 8-36V DC
Pressure rating PN16, PN25, PN40 Mpa
Tube material SS316
Electrode 316L / Hasteloy-C / Ti / Ta / Pt100
Accuracy 0.25% , 0.5%
Communication BACNET/Modbus/RS485/4-20 mA
Totalizer Remote / Compact
Liner material PTFE
Brand Name Iflow
Model Number YF-E80-2
Certification ISO9001, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, D/P, Western Union Supply Ability 1000 sets per month
Delivery Time 2-4 weeks Packaging Details carton / box
Name Flow meter for clean water Power supply 85 - 265V AC / 8-36V DC
Pressure rating PN16, PN25, PN40 Mpa Tube material SS316
Electrode 316L / Hasteloy-C / Ti / Ta / Pt100 Accuracy 0.25% , 0.5%
Communication BACNET/Modbus/RS485/4-20 mA Totalizer Remote / Compact
Liner material PTFE Brand Name Iflow
Model Number YF-E80-2 Certification ISO9001, CE
Place of Origin China
High Light digital water flow metercommercial flow meter

Sanitary flow meter for municipal water utility and food industry, Turbine flowmeter DN80 PN16

 

Main Applications:
Electromagnetic flowmeter can be used to measure the volume flow of conductive fluid in a closed pipeline. It is widely applied in the flow measurement and control in the fields of chemical and petroleum industry, metallurgy industry, water and waste water, agriculture and irrigation, paper making, food and beverage industry and pharmaceutical industry.

 

This technology of magnetic electromagnetic flowmeter has a number of advantages when it comes to liquid flow measurement. The sensors are generally inserted in line into the pipes' diameter, and are therefore designed such that they do not disturb or restrict the flow of the medium under measurement. As the sensors are not directly immersed in the liquid-there are no moving parts-there are no wear and tear concerns.

The method of magnetic electromagnetic flowmeter measures the volume flow, which means the measurement is insensitive to changes in effects such as fluid density, temperature, pressure, and viscosity. Once the electromagnetic water flow sensor measurement transmitter meters is calibrated with water, it can be used to measure the other types of conductive fluid-with no additional correction. This is a significant advantage that other types of flow meters don't have.

 

Key features

  • Maximal uptime with dual-compartment transmitter housing that isolates electronics from moisture and contamination
  • Robust structure, fully welded construction designed to withstand sustained vibration
  • Confirm meter calibration without interrupting the process using continuous meter verification
  • Perform easy repairs in the field without the need to replace the entire meter with a replaceable terminal block
  • Advanced diagnostic capabilities and printed reports verify meter performance for compliance with regulatory agencies
  • Simplify configuration and accessibility with an easy-to-use Local Operator Interface

Accuracy

Pipe Dia (mm) Velocity (m/s) Accuracy
3-20 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout
25-600 0.1-0.3 + 0.25% FS
0.3-1 + 0.5% Readout
1-15 + 0.3% Readout
700-3000 <0.3 + 0.25% FS
0.3-1 + 1.0% Readout
1-15 + 0.25% Readout

 

 

 

 

 

 

 

 

 

 

 

 

 

Technical data

Product name Electromagnetic flowmeter
Product type Local|compact display Remote display Signal converter
Model IYF-E IYF-F IRT
Pipe Diameter (mm) DN10-DN2000
Power supply 100-240 VAC / 18-36 VDC
Accuracy + 0.5% + 0.5% + 0.5%
Power consumption <6w <6w <6w
Enclosure rating IP65 IP68 IP65
Liquid temperature -25-120℃ -25-120℃ -25-120℃
Ambient temperature -25-50℃ -25-50℃ -25-50℃
Relative humidity 10-90% 10-90% 10-90%
Meter ratio 1:100 1:100 1:100
Flow direction Bi-direction flow Bi-direction flow Bi-direction flow
Communication RS485 / Bacnet RS485 / Bacnet RS485 / Bacnet
Signal Output 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency 4-20mA/Pulse/Frequency

 

Manufacture process

Packing

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1966

  • Total Annual:

    15000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai I Fluid Technology Co., Ltd.
  • Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
  • http://www.industrial-watermeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement