Payment Terms | T/T, L/C |
Supply Ability | 2200000 units per year |
Delivery Time | 4-6 weeks |
Packaging Details | wooden case pluse pallet |
Type | waste water flow meter |
Pipe diameter | 2" - 48" |
Application | sewage, waste water, effluent |
Electrode | 316L / Hasteeloy-C / Ti / Ta / Pt100 |
Measure | flow and heat |
Protection | IP68 |
Accuracy | 0.25% , 0.5% |
Connect | flange port |
Brand Name | Iflow |
Model Number | YF-F100-5 |
Certification | ISO9001, CE |
Place of Origin | China |
View Detail Information
Explore similar products
Payable Wastewater Flow Meter Electromagnetic With Dn50 - 1200 Mm Diameter
9000 Cbm / Hour Sewer Flow Meter , Parshall Ultrasonic Open Channel Flow Meter
Pn16mpa Wastewater Flow Meter Hard Rubber Liner For Sewage Flow Metering
Sewage Flow Metering Magnetic Water Meter Hard Rubber Liner With Electrode 316l
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 2200000 units per year |
Delivery Time | 4-6 weeks | Packaging Details | wooden case pluse pallet |
Type | waste water flow meter | Pipe diameter | 2" - 48" |
Application | sewage, waste water, effluent | Electrode | 316L / Hasteeloy-C / Ti / Ta / Pt100 |
Measure | flow and heat | Protection | IP68 |
Accuracy | 0.25% , 0.5% | Connect | flange port |
Brand Name | Iflow | Model Number | YF-F100-5 |
Certification | ISO9001, CE | Place of Origin | China |
High Light | sewer flow meter ,flow meter for sewage water |
Sewage flow meter DN300 Mag Flowmeter Magnetic Flow Meter With Low Pressure Drop
Description
The flanged electromagnetic flowmeter for use in volumetric measurement of conductive fluid, like municipal
or industrial water and waste water applications in which propeller meters have typically been used in the past.
With no moving parts and electrodes designed to discourage fouling, the IYF magmeter require minimal
maintenance in applications in which debris or sand would impede propeller meters. There is no rotor to stop
turning or bearings to wear out.
It’s externally powered with 100-240VAC or 24 VDC. Low power requirements also make it ideal for solar
and comparable power sources. Rate and total indication is standard, as is a solid state pulse / frequency /
4-20mA output, that allows connection to a data logger.
The display housing can be either integrated or remote. A shielded power/pulse output cable with DIN connection
is included with the meter.
Accuracy
Pipe Dia (mm) | Velocity (m/s) | Accuracy |
3-20 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout | |
25-600 | 0.1-0.3 | + 0.25% FS |
0.3-1 | + 0.5% Readout | |
1-15 | + 0.3% Readout | |
700-3000 | <0.3 | + 0.25% FS |
0.3-1 | + 1.0% Readout | |
1-15 | + 0.25% Readout |
Grounding
From flow meter housing terminal G to grounding by minimal 1.6mm2 copper cable, resistivity < 10 Ω.
Technical data
Product name | Electromagnetic flowmeter | ||
Product type | Local|compact display | Remote display | Signal converter |
Model | IYF-E | IYF-F | IRT |
Pipe Diameter (mm) | DN10-DN2000 | ||
Power supply | 100-240 VAC / 18-36 VDC | ||
Accuracy | + 0.5% | + 0.5% | + 0.5% |
Power consumption | <6w | <6w | <6w |
Enclosure rating | IP65 | IP68 | IP65 |
Liquid temperature | -25-120℃ | -25-120℃ | -25-120℃ |
Ambient temperature | -25-50℃ | -25-50℃ | -25-50℃ |
Relative humidity | 10-90% | 10-90% | 10-90% |
Meter ratio | 1:100 | 1:100 | 1:100 |
Flow direction | Bi-direction flow | Bi-direction flow | Bi-direction flow |
Communication | RS485 / Bacnet | RS485 / Bacnet | RS485 / Bacnet |
Signal Output | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency | 4-20mA/Pulse/Frequency |
Features
Mounting notice
Model selection
Applicable metering liquid:
Non-applicable metering medial
Notice on the selection of local type and remote type:
Remote type means the transmitter and converter display are mounted in different locations, it’s suggested to select
remote type in the following conditions:
I | Model | ||||||||
YF | Electromagnetic flowmeter | ||||||||
TF | Turbine | ||||||||
VF | Votex | ||||||||
LX | Vane wheel | ||||||||
T | Ultrasonic | ||||||||
E/F display mode | E: compact/local display, F: remote display | ||||||||
Pipe Dia | Type (mm) | ||||||||
xxxx | 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 400, 500, 600, 800, 1000 | ||||||||
Code | Accuracy | ||||||||
1 | + 0.5% FS | ||||||||
2 | + 1.0% FS | ||||||||
3 | + 0.2% FS | ||||||||
Code | Type | ||||||||
N | Converter: 12 / 24 VDC, pulse output | ||||||||
A | Transmitter: 24VDC, 4-20mA outpt | ||||||||
B | Intelligent, Lion battery, no local display | ||||||||
G | Smart, local display, 4-20mA output | ||||||||
C1 | Smart, local display, RS485 | ||||||||
C2 | Smart, local display, HART | ||||||||
Code | Type | ||||||||
S | Carbon steel housing | ||||||||
L | Stainless steel housing | ||||||||
G | High pressure housing | ||||||||
HL | 316L electrode | ||||||||
HTi | Titanium electrode | ||||||||
HTa | Tantlum electrode | ||||||||
HC | Hastelloy-C electrode | ||||||||
L1 | Liquid media | ||||||||
L2 | Gas media | ||||||||
P | Pressure compensation | ||||||||
T | Temperature compensation | ||||||||
PT | Pressure&Temp. Compensation | ||||||||
F | PTFE liner | ||||||||
X | Rubber liner | ||||||||
Sample: IYF-E-0100-1-C1-S-HL-L1-F, Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt, RS485, 316L electrodes, liquid media meter, PTFE liner |
Pipe Diameter, flow volume and product dimension
Dia | Flow volume (m3/h) | Product dimension (mm) | |||||
(mm) | Normal | Min | Max | L | D | H | H1 |
15 | 1.5 | 0.06 | 9.5 | 150 | 95 | 272 | 254 |
20 | 2.5 | 0.11 | 16.9 | 105 | 277 | 254 | |
25 | 3.5 | 0.18 | 26.5 | 115 | 283 | 254 | |
32 | 6 | 0.29 | 43.6 | 140 | 297 | 270 | |
40 | 10 | 0.45 | 67.8 | 150 | 307 | 280 | |
50 | 15 | 0.71 | 106.0 | 200 | 165 | 318 | 294 |
65 | 25 | 1.19 | 179.1 | 185 | 337 | 313 | |
80 | 40 | 1.81 | 271.4 | 200 | 352 | 326 | |
100 | 60 | 2.83 | 424.1 | 250 | 220 | 371 | 344 |
125 | 100 | 4.42 | 665 | 250 | 401 | 372 | |
150 | 135 | 6.36 | 954 | 300 | 285 | 431 | 403 |
200 | 250 | 11.3 | 1696 | 350 | 340 | 486 | 460 |
250 | 375 | 17.66 | 2650 | 400 | 395 | 547 | 511 |
300 | 540 | 25.43 | 3817 | 450 | 445 | 597 | 565 |
350 | 735 | 34.62 | 5195 | 505 | 657 | 620 | |
400 | 960 | 45.22 | 6785 | 500 | 565 | 717 | 675 |
450 | 1200 | 57.23 | 8588 | 550 | 615 | 757 | 727 |
500 | 1500 | 70 | 10602 | 600 | 670 | 817 | 782 |
600 | 2160 | 100 | 15268 | 780 | 917 | 782 | |
700 | 2950 | 138 | 20781 | 700 | 895 | 1027 | 1068 |
800 | 3850 | 180 | 27100 | 800 | 1015 | 1137 | 1157 |
Industrial applications
Chemical | Food & beverage | Paper mill |
Metallurgy | Environment protection | Hydraulic |
Mining | Stainless | Petroleum |
Pharmacy | Air conditioner | Effluent treatment plant |
Seawater desalination | Pharmacy | Water treatment |
Competitive advantage
Process control
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1966
Total Annual:
15000000-20000000
Employee Number:
400~500
Ecer Certification:
Active Member
Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote...
Get in touch with us
Leave a Message, we will call you back quickly!