China Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter
China Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter

  1. China Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter
  2. China Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter

Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter

  1. MOQ: negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 5000 pieces per month
Delivery Time 1-2 weeks
Packaging Details carton / wooden case
Type open channel flow meter
Max velocity 64m/s
Transducer ultrasonic
Accuracy +/- 1%
Communication 4-20 MA / OCT Pulse / Relay
flume parshall
Power 85-265V AC / 8-36V DC
Brand Name Iflow
Model Number WGM45-1
Certification ISO9001, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 5000 pieces per month
Delivery Time 1-2 weeks Packaging Details carton / wooden case
Type open channel flow meter Max velocity 64m/s
Transducer ultrasonic Accuracy +/- 1%
Communication 4-20 MA / OCT Pulse / Relay flume parshall
Power 85-265V AC / 8-36V DC Brand Name Iflow
Model Number WGM45-1 Certification ISO9001, CE
Place of Origin China
High Light transit time flow metermass flow meter

integrated open channel flow meter, ultrasonic flow and level meter for ETP 9000m3/h

Work principle
Ultrasonic transducer, is a transceiver which emits high frequency sound, which hits the medium surface and returns back to the sensor receiver. The time of travel of the ultrasound is inversely proportional to the height of the flowing medium. This way the height of the flowing medium is calculated. And with the algorithms programmed the Height, Flowrate and Total Flow are calculated and displayed.

General introduction
The Open channel Ultrasonic Flowmeter is a high precision flow measurement instrument, which use Transit Time Ultrasound principle to measure the flow in a variety of Flumes, Weirs or Troughs.

Main technical index

Model WH
Applicable weirs Right triangle weir slot (Open size: 500mm)
  Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm)
  Rectangular weir (Opening size: 250mm, 500mm, 750mm )
Flow range depending on weirs dimensions to be used, up to 335000 m3/hr
Flow precision 5% FS
Level range 1m
Level precision 0.5% FS
Sensor blind area <300mm @ 25C
Output 4-20 mA, tri wires
Display LCD display, include: four levels
four transient flow
Eight of the accumulative total flow
16 calendar clock
Work temperature 50C , customized available
Power supply AC220V
Outlet way Sensor leads 20m, instrument standard plugs
Installation instrument wall mount, sensor grain installation M49x1.5, or clamp on
Protection IP66 (sensor)


Dimensions
Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
Features

  •  Built-in variety of algorithms, suitable for a variety of standard weirs.
  •  Stable sensors - Suitable for harsh industrial situations
  •  Isolated 4~20mA current output. Optional spot bus interface.
  •  The blind zone can be manually set, shielding the probe near the interference signal.
  •  Calibrated at Factory. And if required we shall do calibration at site.

Sensors
Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient TemperatureEffluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
Ultrasonic sensor Static pressure sensor
Applications
Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.
Flow Totalizer parameters
Flow measuring range: Depends on the size of the flume.
Maximum Count: 9999999999
Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.

Output
Voltage output: DC 12V or 24V
Signal output: RS485/RS232; 4~20mA; 2 channel relay

Troughs
Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
Triangle weirs
Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature
Installation sample
Effluent Treatment Plant Electromagnetic Ultrasonic Flow Meters -40 C - 55 C Ambient Temperature

Advantage
The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1966

  • Total Annual:

    15000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai I Fluid Technology Co., Ltd.
  • Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
  • http://www.industrial-watermeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement