RS232 AC 220V Open Channel Flow Meter Level Transmitter Static Pressure Sensor

  1. MOQ: negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 1000 sets per month
Delivery Time 1-2 weeks
Packaging Details carton
Type open channel flow meter
Flow range 0 - 335000 m3/h
Accuracy +/- 2.5%
Display LCD
Communication RS232, RS485
Output 4-20mA
Power supply 85 - 265V AC / 8-36V DC
Brand Name Iflow
Model Number WGM45
Certification ISO9001
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 1000 sets per month
Delivery Time 1-2 weeks Packaging Details carton
Type open channel flow meter Flow range 0 - 335000 m3/h
Accuracy +/- 2.5% Display LCD
Communication RS232, RS485 Output 4-20mA
Power supply 85 - 265V AC / 8-36V DC Brand Name Iflow
Model Number WGM45 Certification ISO9001
Place of Origin China
High Light transit time flow metermass flow meter

Open channel flow meter for effluent flow monitor, parshal flume, level transmitter

 

Product introduction

The Open channel Ultrasonic Flowmeter is a high precision flow measurement instrument, which use Transit Time Ultrasound principle to measure the flow in a variety of Flumes, Weirs or Troughs.

 

 

Features

 

  •  With a fully independent intellectual property rights.
  •  Has wide range of temperature compensation and original ERD interference intelligent identification system, measurement data stability, high precision.
  •  Six groups flow condition all data sending 485 serial ports output, PC directly receive, decimal shows, the convenient user record and read archived.
  •  Original "fluid flow correction system" that flow coefficient according to slot size and level to be automatic operation weir and timing compensation.
  •  The blackout time time, the year/month/day/when/points/SEC, flow data, using the ferroelectric double backup storage 10 years off.
  •  Original "measuring tank jam recognition alarm system" can detect liquid slag quality measurement slot throat and obstruction caused by measurement.
  •  Precise date determined when the calendar clock Settings, display and cooperate with the memo and time axis to file information records.
  •  Has 4~20 mA three wire system, RS485, switch quantity and so on many kinds of signal output function selection.
  •  Using intelligent measuring high, digital calibration, the user installation calibration simple and quick.
  •  The ultrasonic non-contact measurement with no moving parts, flow without components within, no block sensor fault hidden trouble.

Sensors

Ultrasonic sensor Static pressure sensor

 

 

Main technical index

Model WH
Applicable weirs Right triangle weir slot (Open size: 500mm)
  Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm)
  Rectangular weir (Opening size: 250mm, 500mm, 750mm )
Flow range depending on weirs dimensions to be used, up to 335000 m3/hr
Flow precision 5% FS
Level range 1m
Level precision 0.5% FS
Sensor blind area <300mm @ 25C
Output 4-20 mA, tri wires
Display

LCD display, include: four levels

four transient flow

Eight of the accumulative total flow

16 calendar clock

Work temperature 50C , customized available
Power supply AC220V
Outlet way Sensor leads 20m, instrument standard plugs
Installation instrument wall mount, sensor grain installation M68x2.0, or clamp on
Protection IP66 (sensor)

 

 

 

Applications
Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.


Flow Totalizer parameters
Flow measuring range: Depends on the size of the flume.
Maximum Count: 9999999999
Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.

 

Output
Voltage output: DC 12V or 24V
Signal output: RS485/RS232; 4~20mA; 2 channel relay

 

Troughs

Triangle weirs

Installation sample

 

Advantage

The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1966

  • Total Annual:

    15000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai I Fluid Technology Co., Ltd.
  • Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
  • http://www.industrial-watermeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement