Payment Terms | T/T, L/C, Western Union |
Supply Ability | 5000 pieces per month |
Delivery Time | 1-2 weeks |
Packaging Details | carton / wooden case |
Name | open channel flowmeters |
Accuracy of level | 0.25% F.S |
Precision of flow | 1% |
level range | 2m |
Protection | IP66 |
Weir type | parshall, square weir |
Power | 85-265V AC / 8-36V DC |
Brand Name | Iflow |
Model Number | WG |
Certification | ISO9001, CE |
Place of Origin | China |
View Detail Information
Explore similar products
RS232 AC 220V Open Channel Flow Meter Level Transmitter Static Pressure Sensor
Parshall Flume Ultrasonic Flow Meter Open Channel For Effluent Treatment Plant
Integration Open Channel Flow Meter , 85 265V AC Ultrasonic Flow Meter
Parshall Flume Open Channel Flow Meter IP66 For Canal Irrigation
Product Specification
Payment Terms | T/T, L/C, Western Union | Supply Ability | 5000 pieces per month |
Delivery Time | 1-2 weeks | Packaging Details | carton / wooden case |
Name | open channel flowmeters | Accuracy of level | 0.25% F.S |
Precision of flow | 1% | level range | 2m |
Protection | IP66 | Weir type | parshall, square weir |
Power | 85-265V AC / 8-36V DC | Brand Name | Iflow |
Model Number | WG | Certification | ISO9001, CE |
Place of Origin | China | ||
High Light | mass flow meter ,digital flow meter |
open channel flowmeter for waste water treatment ETP flow monitor, ultrasonic flow meters,
How to use
The velocity of the solid particles in slurry can be different than its liquid carrier fluid. Be careful applying ultrasonic technology when the solid particles can become concentrated in one part of the flowing stream, such as in a horizontal pipe flowing at a relatively low velocity. Be careful when applying Doppler ultrasonic flowmeters in slurry applications because the solid particles can produce strong signals that can cause the Doppler flowmeter to measure the velocity of the solids and not the velocity of the liquid.
For transit time ultrasonic flowmeters, be sure that the fluid can adequately conduct ultrasonic waves, because the flowmeter will not measure when the ultrasonic waves cannot penetrate the flow stream between the transducers. Similarly, ultrasonic waves must be able to penetrate the fluid for Doppler flowmeters to operate accurately. When the fluid is relatively opaque and does not penetrate the fluid, Doppler flowmeters tend to measure the velocity of the fluid at or near the pipe wall, which can cause significant measurement error and/or cause the flowmeter to fail.
The main function characteristics:
Technical parameters
Applicable weir: Right angled triangle weir:The size of the opening 500mm
Rectangular weir:The size of the opening 250mm,500mm,750mm,1000mm
Bashir slot: Larynx way width: 25mm,51mm,76mm,152mm,228mm
Flow range:according to weir/flume size
Function characteris tics: data storage 1 year, can be arbitrary time of the inquiry
Flow precision: 1~5% F·S
Level range:2m
Level precision:±0.25% F·S (at times, and the blind process ℃)
Probe blind area:≤300mm (at 25 ℃)
Output signal:4~20 mA +RS485
Showing the way:16 LCD display,
Among them:Four level height,Four transient flow,Eight of the accumulative total flow,
16 the calendar clock (buttons when)
Working temperature:-10~60℃(default),can be customized of level: 0~80℃
Work power:AC220V/50Hz,or DC24V/300m
Outlet way: instrument standard plugs, Liquid level meter quick connect,
Installation:instrument wall hung installation; Sensor gongs grain installation M68×2.0mm, or gongs circle clampon installation
Protection level: IP66
Operation environment: constant pressure, not anti-explosion, not anti-corrosion
Data sheet
Model | WH |
Applicable weirs | Right triangle weir slot (Open size: 500mm) |
Parshall flume (Larynx way width: 51mm, 76mm, 152mm, 228mm, 300mm) | |
Rectangular weir (Opening size: 250mm, 500mm, 750mm ) | |
Flow range | depending on weirs dimensions to be used, up to 335000 m3/hr |
Flow precision | 5% FS |
Level range | 1m |
Level precision | 0.5% FS |
Sensor blind area | <300mm @ 25C |
Output | 4-20 mA, tri wires |
Display | LCD display, include: four levels four transient flow Eight of the accumulative total flow 16 calendar clock |
Work temperature | 50C , customized available |
Power supply | AC220V |
Outlet way | Sensor leads 20m, instrument standard plugs |
Installation | instrument wall mount, sensor grain installation M49x1.5, or clamp on |
Protection | IP66 (sensor) |
Dimensions
Features
Sensors
Ultrasonic sensor Static pressure sensor
Applications
Measurement of water flow in Effluent, Waste Water, Rivers, Canals, Drains, Sewage, etc.
Flow Totalizer parameters
Flow measuring range: Depends on the size of the flume.
Maximum Count: 9999999999
Types of suitable weirs: Triangular weir, rectangular weir, Parshall flume, etc.
Display accuracy: 1 count. Overall accuracy depends on the input signal. Different Weirs /
flumes has different accuracies. A triangular weir has 1 to 2% flow error, a rectangular weir
has 1 to 4% accuracy, a Parshall flume has 3% flow error, etc.
Display: 2.8-inch LCD. Displays Height, Flowrate, Total Flow, etc.
Output
Voltage output: DC 12V or 24V
Signal output: RS485/RS232; 4~20mA; 2 channel relay
Triangle weirs
Installation sample
Advantage
The production capacity is 20000 ultrasonic converter and 100,000 ultrasonic sensor.
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1966
Total Annual:
15000000-20000000
Employee Number:
400~500
Ecer Certification:
Active Member
Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote...
Get in touch with us