China factories

China factory - Shanghai I Fluid Technology Co., Ltd.

Shanghai I Fluid Technology Co., Ltd.

  • China,Shanghai ,Shanghai
  • Active Member

Leave a Message

we will call you back quickly!

Submit Requirement
China Metal Rota High Pressure Gas Flow Meter , Flange Port Industrial Flow Meter
China Metal Rota High Pressure Gas Flow Meter , Flange Port Industrial Flow Meter

  1. China Metal Rota High Pressure Gas Flow Meter , Flange Port Industrial Flow Meter
  2. China Metal Rota High Pressure Gas Flow Meter , Flange Port Industrial Flow Meter

Metal Rota High Pressure Gas Flow Meter , Flange Port Industrial Flow Meter

  1. MOQ: negotiable
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C, Western Union
Supply Ability 500 sets per month
Delivery Time 2-4 weeks
Packaging Details carton
Name metal rota flow meters
Pipe size DN15 - DN100
Accuracy 0.5% at liquid, 1% at gas, 1.5% at steam
Compensation temperature / pressure / temp. & pressure
Connect quick connect flange
Pressure rating PN1.0 Mpa to PN40 Mpa
Option weight flow or cubic flow
Flow direction horizontal
Brand Name Iflow
Model Number LZ100
Certification ISO9001, CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C, Western Union Supply Ability 500 sets per month
Delivery Time 2-4 weeks Packaging Details carton
Name metal rota flow meters Pipe size DN15 - DN100
Accuracy 0.5% at liquid, 1% at gas, 1.5% at steam Compensation temperature / pressure / temp. & pressure
Connect quick connect flange Pressure rating PN1.0 Mpa to PN40 Mpa
Option weight flow or cubic flow Flow direction horizontal
Brand Name Iflow Model Number LZ100
Certification ISO9001, CE Place of Origin China
High Light high pressure flow meterhigh pressure gas flow meter

Metal rota high pressure air flow meters for oil and high pressure gas Pipe size DN15-100

 

Work principle

The metal flowmeter's flow sensing element consists of a vertical tapered tube expanding from bottom to top and a float set moving up and down along the tapered tube axis. Working principle shown in Figure 1, the measured fluid from the bottom up through the conical tube 1 and the float 2 formed ring gap 3, the upper and lower ends of the float to produce differential pressure to form the floating force of the float when the lift is greater than the submerged fluid The weight of the float, the float will rise, the ring gap area increases, the annular gap at the immediate decline in fluid flow velocity, the float lower differential pressure decreases, the role of the buoy lift force also decreases until the lifting force is equal to immersed in the fluid In the float weight, the float will be stable at a certain height. The height of the float in the conical tube and the flow through the corresponding relationship.

The basic equation of volume flow Q is:

When the float is non-solid hollow structure (put the weight adjustment), then

Where α - instrument flow coefficient, due to float shape varies;
ε - gas expansion coefficient measured gas is gas, usually due to the small coefficient of this correction is ignored, and has been included in the flow coefficient through the calibration, such as liquid, then ε = 1;
△ F - Circulation area, m2;
g - local acceleration of gravity, m / s2;
Vf - float volume, if extended body should also include, m3;
ρf - float material density, kg / m3;
ρ - measured fluid density, such as gas is the density of the upstream cross-section of the float, kg / m3;
Ff - working area of ​​the float (maximum diameter) cross-sectional area, m2;
Gf - float quality, kg.
Circulation area and the relationship between the height of the float as shown in equation (3), when the structural design has been set, then d, β are constant. There is a quadratic term in h, we can not ignore this nonlinear relationship. Only when the cone angle is small, can we regard it as approximate linearity.
m2 (3)
Where d - maximum diameter of the float (ie, working diameter), m;
h - float from the cone diameter equal to the maximum diameter of the float rise height, m;
β - taper cone angle;
a, b - constant.

 

Data sheet

Diameter(mm) Flow range Pressure loss
Anticorrosion Normal air(m3/h at 0.1013Mpa) water L/h air water
15 15 0.07-0.7 2.5-25 7.1 6.5
0.11-1.1 4.0-40 7.2 6.5
0.18-1.8 6.3-63 7.3 6.6
0.28-2.8 10-100 7.5 6.6
0.4-4.0 16-160 8.0 6.8
0.7-7.0 25-250 10.8 7.2
1.0-10 40-400 10 8.6
25 1.6-16 63-630 14 11.1
25 3.0-30 100-1000 7.7 7
4.5-45 160-1600 8.8 8
7.0-70 250-2500 12 10.8
50 11-110 400-4000 19 15.8
50 18-180 630-6300 8.6 8.1
25-250 1000-10000 10.4 11
80 40-400 1600-16000 15.5 17
80 60-600 2500-25000 8.0 8.1
100 100-1000 4000-40000 13.0 9.5
  100 200-2000 6300-63000 11.0 10

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1966

  • Total Annual:

    15000000-20000000

  • Employee Number:

    400~500

  • Ecer Certification:

    Active Member

Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity.   To adapt to the global environment prote...

+ Read More

Get in touch with us

  • Reach Us
  • Shanghai I Fluid Technology Co., Ltd.
  • Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
  • http://www.industrial-watermeter.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement