Payment Terms | T/T, L/C |
Supply Ability | 2200000 units per year |
Delivery Time | 4-6 weeks |
Packaging Details | wooden case pluse pallet |
Type | ultrasonic water meter transit time |
Port size | 1-1/4 inch |
Connect port | thread |
R value | 160 / 250 / 400 |
Work | transit time |
Protection | IP68 |
Electromagnetic compatibility | Class E2 |
Communication | RS485 Modbus / Nb / Lora |
Brand Name | Iflow |
Model Number | T3-1 |
Certification | ISO 4064, GB/T19001 |
Place of Origin | China |
View Detail Information
Explore similar products
Brass Tubing Potable Water Flow Meter , Ultrasonic R500 Industrial Water Meter
Flange Port Cast Iron Ultrasonic Flow Meter , ISO 4064 Bidirectional Liquid Flow
AMI 1.6 Mpa External Water Flow Meter , Brass Housing LCD Display Water Flow
RS - 485 Class B Hot Water Meter For Energy Management Brass Body DN25
Product Specification
Payment Terms | T/T, L/C | Supply Ability | 2200000 units per year |
Delivery Time | 4-6 weeks | Packaging Details | wooden case pluse pallet |
Type | ultrasonic water meter transit time | Port size | 1-1/4 inch |
Connect port | thread | R value | 160 / 250 / 400 |
Work | transit time | Protection | IP68 |
Electromagnetic compatibility | Class E2 | Communication | RS485 Modbus / Nb / Lora |
Brand Name | Iflow | Model Number | T3-1 |
Certification | ISO 4064, GB/T19001 | Place of Origin | China |
High Light | ultrasonic water flow meter ,modbus water meter |
Ultrasonic water meter for waste water treatment | ETP, made of brass | copper DN15
Description:
The dual channel ultrasonic water meter is designed and developed according to ISO4064-1:2005 / GBT778-2007
JJG162-2009. It has advantages of low power consumption, stable and reliable operation. Enclosure protection is
IP68. They’re widely applied in municipal water supply, water resourse management, agricultrual, irrigation,
garden management.
Data sheet
Description | Specifications |
Standard | ISO 4064-2005 , GBT 778.1-2007 |
Liquid media | Liquid is full of pipe line, such as water, sewage, seawater, effluent, waste water, slurry, etc. |
Media temperature | 0.1 - 30℃ |
Work environment | Temperature: -10-45℃ , Relative Humidity: <100% |
Operate pressure | 1.6Mpa (optional 2.5Mpa) |
Upstream sensivity | U3 |
Downstream sensitivity | D0 |
Climatic and mechanical | Class C |
EMC class | E2 |
Communication | RS485 / USART / Infrared |
Signal output | Two way OCT pulse / TTL pulse / One-way 4-20mA |
Power supply | Built-in Lithium battery, (3.6V @ 19Ah) / DC8-36V |
Protection | IP68 (submersible up to 2 meters depth) |
Display | Multiline 9 digit accumulative flow, 4 digit velocity, |
Data storage | EEPROM / Flash, automatically record 512 days accumulative flow |
Metering cycle | Measure: 1 times/second ; Verificaiton: 4times/second |
Power consumption | <2.7Ah/year, 6 years battery life |
Overview
Display and operation
Communication and signal output
RS485 | OCT1 (open collector output 1) |
M-BUS | OCT2 (open collector output 2) |
DC8-36V | C1 (TTL level pulse output 1) |
Two-way 4-20mA output | C2 (TTL level pulse output 2) |
Material
DN15-DN40 Single channel ultrasonic water meter (copper)
DN50-DN40 Dual channel bulk ultrasonic water meter (cast iron)
DN200-DN300 Dual channel large ultrasonic water meter (welded carbon steel)
Flow range
Nominal D | R | Flow (m3/h) | ||||
Starting flow | Minimal flow (Q1) | Transitional flow (Q2) | Normal flow (Q3) | Overload flow (Q4) | ||
DN15 | 200 | 0.003 | 0.0125 | 0.020 | 2.500 | 3.125 |
DN20 | 200 | 0.0035 | 0.016 | 0.026 | 3.200 | 4.000 |
DN25 | 200 | 0.007 | 0.020 | 0.032 | 4.000 | 5.000 |
DN32 | 200 | 0.010 | 0.032 | 0.050 | 6.300 | 7.875 |
DN40 | 200 | 0.015 | 0.100 | 0.160 | 20.000 | 25.000 |
DN50 | 100 | 0.030 | 0.400 | 0.640 | 40.000 | 50.000 |
DN65 | 100 | 0.059 | 0.630 | 1.008 | 63.000 | 78.750 |
DN80 | 100 | 0.064 | 1.000 | 1.600 | 100.000 | 125.000 |
DN100 | 100 | 0.094 | 1.600 | 2.560 | 160.000 | 200.000 |
DN125 | 100 | 0.120 | 2.000 | 3.200 | 200.000 | 250.000 |
DN150 | 100 | 0.270 | 2.500 | 4.000 | 250.000 | 312.500 |
DN200 | 100 | 0.315 | 4.000 | 6.400 | 400.00 | 500.00 |
DN250 | 100 | 0.508 | 4.000 | 6.400 | 400.00 | 500.00 |
DN300 | 100 | 0.770 | 6.300 | 10.080 | 630.00 | 787.500 |
Competitive Advantage:
Competitive Advantage:
Production line
Competitive Advantage:
Calibration equipment
Company Details
Business Type:
Manufacturer,Exporter
Year Established:
1966
Total Annual:
15000000-20000000
Employee Number:
400~500
Ecer Certification:
Active Member
Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote... Shanghai I Fluid Technology Co., Ltd, a technique based company. We focus on the deployment , installation and management system of smart metering and smart grid in all utility sectors, include but not limited to water, heat, gas and electricity. To adapt to the global environment prote...
Get in touch with us
Leave a Message, we will call you back quickly!