China Industrial Switch Socket Change Over Contactor 50 Amp 80 Amp
China Industrial Switch Socket Change Over Contactor 50 Amp 80 Amp

  1. China Industrial Switch Socket Change Over Contactor 50 Amp 80 Amp

Industrial Switch Socket Change Over Contactor 50 Amp 80 Amp

  1. MOQ: 500pcs
  2. Price: Negotiable
  3. Get Latest Price
Payment Terms T/T, L/C
Supply Ability 50000 pcs per month
Delivery Time 20 days and depends on ordering quantity
Packaging Details Each unit packed in a individual box
Brand KRIPAL
Current Range 50A 65A 75A 85A
Poles 3 pole
Auxiliary 2NO+2NC
Contacts silver 85% Ag
Coil AC
Brand Name KRIPAL
Model Number UKC1-.....C
Certification CE
Place of Origin China

View Detail Information

Contact Now Ask for best deal
Get Latest Price Request a quote
  1. Product Details
  2. Company Details

Product Specification

Payment Terms T/T, L/C Supply Ability 50000 pcs per month
Delivery Time 20 days and depends on ordering quantity Packaging Details Each unit packed in a individual box
Brand KRIPAL Current Range 50A 65A 75A 85A
Poles 3 pole Auxiliary 2NO+2NC
Contacts silver 85% Ag Coil AC
Brand Name KRIPAL Model Number UKC1-.....C
Certification CE Place of Origin China
High Light heat pump contactor ac magnetic contactor

 

Industrial Switch Socket Change Over Contactor 50 Amp 80 Amp

 

 

Description:

 

As it is known, when the capacitor starts to operate, they cause a high frequency between 1~15kHz. And a current that is 180time higher than rated current for very short time period. Shock inductance is to be fixed to each phase to limit this current. But practically this type of operation is difficult. That's why capacitor switching contactors are used and for this reason the life-time of contactors increase 100% in comparision with normal contactor. Example: if electrical life of normal contactor is 100,000times in max load, electrical life of capacitor switching contactor is 200,000times.


While Switching on a capacitive circuit, a high frequency (1...15kHz) and large transient current Peaks are produced. Switching of capacitor for a single or one of the capacitor banks are different from each other. Step by step "switching on" operation is more difficult for contactor than capacitor bank. Because during this operation for capacitor bank, compensated current occurs. For this reason selecting of a suitable contactors the compensating current must be take into consideration for 50kVAr and above, and for less than 50kVAr can be ommitted.

 

Operating Principle: When coil of contactor is energized, first contact of passing block is closed, starting current of contactor is passed through this contact, approximately after 3-5 ms contacts of passing blocks are opened and rated current of contactor is carried on main contacts.

 

 

Specifications:

 
Operatingferquency (cycles/hour) UKC(D)1-9C,12C,18C,22C,32C,40C 2X40 times/hour
UKC(D)1-50C,65C,75C,85C 100 times/hour
Electrical life (times) UKC(D)1-9C,12C,18C,22C,32C,40C 200000  times/hour
UKC(D)1-50C,65C,75C,85C 100000 times/hour
 Model Max.power of motor (kvar) Rated Current Applicable Unit
220-240V 400-440V 550-600V
UKC(D)1-9C 5 9.7 14 14 AC-9
UKC(D)1-12C 6.5 12.5 18 18 AC-9
UKC(D)1-18C 8.5 16.7 24 24 AC-9
UKC(D)1-22C 10 18 26 26 AC-9
UKC(D)1-32C 15 25 36 36 AC-9
UKC(D)1-40C 20 33.3 48 48 AC-9
UKC(D)1-50C 22 40 58 58 AC-50
UKC(D)1-65C 25 45.7 66 66 AC-50
UKC(D)1-75C 29.7 54 78 78 AC-50
UKC(D)1-85C 35 60 92 92 AC-50

 

 

Operation Condition:

 

1. When the switch is closed condenser must be discharged before recharged.

(Maximum residual voltage at terminals ≤ 50V)

 

2. In working voltage 500V (Ue=500V), 100,000 times for UKC1(D)-9C~40C and 80,000 times for UKC(D)1-50C~85C

 

3. To prevent short current, gG type Fuse must be 1.5~2 times than rated current.

 

4. It must be separated from resistant wire

 

5. The average temperature over a 24-hour period, in accordance with standards IEC70 and 831 is 45 degree

 

 

External dimensions:

 

 

 

Company Details

Bronze Gleitlager

,

Bronze Sleeve Bushings

 and 

Graphite Plugged Bushings

 from Quality China Factory
  • Business Type:

    Manufacturer,Exporter

  • Year Established:

    1987

  • Total Annual:

    30000000-35000000

  • Employee Number:

    500~700

  • Ecer Certification:

    Active Member

Zhejiang Kripal Electric Co.,Ltd is one of the national new high-tech enterprises integrated of researching, producing and selling water-proof electric, low-voltage electric and new energy electric products. Established in 1992, Kripal now is gradually becoming the influential electric manufactur... Zhejiang Kripal Electric Co.,Ltd is one of the national new high-tech enterprises integrated of researching, producing and selling water-proof electric, low-voltage electric and new energy electric products. Established in 1992, Kripal now is gradually becoming the influential electric manufactur...

+ Read More

Get in touch with us

  • Reach Us
  • Zhejiang KRIPAL Electric Co., Ltd.
  • Daqiao Industrial Zone, Baixiang Town,Yueqing 325603,Zhejiang, China
  • https://www.industrialswitchsocket.com/

Leave a Message, we will call you back quickly!

Email

Check your email

Phone Number

Check your phone number

Requirement Details

Your message must be between 20-3,000 characters!

Submit Requirement