Payment Terms | L/C, T/T |
Supply Ability | 500 unit per month |
Delivery Time | 30 days |
Packaging Details | ply-wood or plastic film |
Alternator Brand | Stamford, Leroy Somer, Marathon, etc. |
Control Panel | Smartgen, Deepsea, ComAp, etc. |
Cooling System | Water Cooled |
Dimension | Varies |
Engine Brand | Perkins |
Fuel Type | Diesel |
Noise Level | ≤75dB(A) |
Power | 150kVA |
Product Name | Industrial Generator Set |
Rated Frequency | 50Hz |
Rated Speed | 1500rpm |
Rated Voltage | 220/380V |
Starting System | Electric/Manual |
Weight | 2090kg |
Brand Name | Hosem |
Model Number | A-P165 |
Certification | CE/ISO9001 |
Place of Origin | CHINA |
View Detail Information
Explore similar products
2206C-E13TAG2 Diesel Engine 350kVA Perkins Generator Set
Stamford Alternator 500kVA Perkins Diesel Power Generator
1103A-33TG2 50Hz 60kVA Perkins Electric Generator
4008-30TAG3 1125kVA 1000kW Perkins Generator Set
Product Specification
Payment Terms | L/C, T/T | Supply Ability | 500 unit per month |
Delivery Time | 30 days | Packaging Details | ply-wood or plastic film |
Alternator Brand | Stamford, Leroy Somer, Marathon, etc. | Control Panel | Smartgen, Deepsea, ComAp, etc. |
Cooling System | Water Cooled | Dimension | Varies |
Engine Brand | Perkins | Fuel Type | Diesel |
Noise Level | ≤75dB(A) | Power | 150kVA |
Product Name | Industrial Generator Set | Rated Frequency | 50Hz |
Rated Speed | 1500rpm | Rated Voltage | 220/380V |
Starting System | Electric/Manual | Weight | 2090kg |
Brand Name | Hosem | Model Number | A-P165 |
Certification | CE/ISO9001 | Place of Origin | CHINA |
High Light | 150kva perkins generator set ,1500rpm perkins generator set ,150kva perkins dg set |
Generator Set Specification | ||
Model | A-P165 | |
Max. Power | kVA | 165 |
kW | 132 | |
Rate Power | kVA | 150 |
kW | 120 | |
Frequency | Hz | 50 |
Rate Voltage | V | 400/230 |
Rate Current | A | 216.5 |
Fuel Tank Capacity | L | 300 |
Dimension For Open-type Genset | mm | 2450 X 800 X 1400 |
Weight For Open-type Genset | kg | 1590 |
Dimension For Soundproof Genset | mm | 3200 X 1080 X 1500 |
Weight For Soundproof Generator | kg | 2090 |
Noise Level for Soundproof Generator at 7M | dBA | 75 |
Battery for Starting | One of 120A Free Maintenance Battery |
Engine Specification | ||
Engine Manufacturer | Perkins | |
Engine Brand | Perkins | |
Engine Model | 1106A-70TAG2 | |
No. of Cylinder | 6 Cylinder in line | |
Aspiration | Turbocharged and Air to Air Aftercooled | |
Governor | Electric | |
Engine Max. Output Power | kW | 153.6 |
Displacement | L | 7.0 |
Compression Ratio | 16.0 : 1 | |
Starting Voltage | V | 12 |
Bore | mm | 105 |
Stroke | mm | 135 |
Lubrication Oil Capacity | L | 16.5 |
Intake Air Flow | M3/Min | 9.4 |
Fuel Consumption at 100% Load | L/H | 33.4 |
Alternator Specification | ||
Alternator Manufacturer | Cummins Generator Technologies | |
Alternator Model | UCI 274 F | |
Alternator Brand | Stamford | |
Rate Output | kVA | 160 |
Frequency | Hz | 50Hz |
Altitude | M | ≤1000 |
Insulation | Class H | |
Phase | 3 Phase | |
Working Temperature without power decrease | ≤40℃ | |
Working Altitude without power decrease | ≤1000m | |
Automatic Voltage Regulation | SX440 | |
Protection Grade | IP23 | |
Alternator for optional | Leroy Somer, Marathon, Mecc Alte and Hosem Brushless alternator for optional | |
https://wa.me/message/SNIZE4WTMHETB1
FAQ
What Size Generator Set Do I Need?
The size of the generator set you need depends on the total electrical load you want to power during an outage. Contact us, we can help you calculate your power requirements and recommend an appropriate generator size.
What is Standby Power vs. Prime Power?
Standby power generators are designed for backup use and have variable load capacity. Prime power generators are designed for continuous use at a constant load, such as in remote areas or off-grid applications.
What Maintenance is Required for Generator Sets?
Regular maintenance is essential to ensure the reliability of a generator set. Maintenance tasks include oil and filter changes, fuel system checks, cooling system inspection, battery maintenance, and periodic load testing.
How Long Can a Generator Run Continuously?
The continuous runtime of a generator depends on factors like fuel capacity, load, and maintenance. Some generators can run for several hours to days on a single tank of fuel.
Company Details
Business Type:
Manufacturer,Exporter,Seller,Other
Year Established:
2006
Total Annual:
8000000-10000000
Employee Number:
>100
Ecer Certification:
Verified Supplier
Fuzhou Hosem Power Co., Ltd. is one of the most famous diesel generator manufacturers in China. The Hosem brand generator set output range from 3kVA to 3000kVA with frequency at 50Hz or 60Hz, the voltage of the diesel generator from 110kVA to 690V for client options. The diesel generato... Fuzhou Hosem Power Co., Ltd. is one of the most famous diesel generator manufacturers in China. The Hosem brand generator set output range from 3kVA to 3000kVA with frequency at 50Hz or 60Hz, the voltage of the diesel generator from 110kVA to 690V for client options. The diesel generato...